Napoleon Fireplaces GI3016-P manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces GI3016-P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces GI3016-P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces GI3016-P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Napoleon Fireplaces GI3016-P should contain:
- informations concerning technical data of Napoleon Fireplaces GI3016-P
- name of the manufacturer and a year of construction of the Napoleon Fireplaces GI3016-P item
- rules of operation, control and maintenance of the Napoleon Fireplaces GI3016-P item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces GI3016-P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces GI3016-P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces GI3016-P.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces GI3016-P item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 W415-0171 / D / 01.06.04 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTE[...]

  • Page 2

    2 W415-0171 / D / 01.06.04 10-11 OPERA TION / MAINTENANCE Operating Instructions Fresh Air Damper System Maintenance 11 BL OWER INST ALLA TION Blower Replacement Instructions 1 1 ADJUSTMENTS V enturi Adjustments Pilot Burner Adjustment 12-13 REPLACEMENTS Ordering Replacement Parts Replacement Parts Accessories 14-15 TROUBLE SHOOTING GUIDE P G 2- 5 [...]

  • Page 3

    3 W415-0171 / D / 01.06.04 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test[...]

  • Page 4

    4 W415-0171 / D / 01.06.04 The fireplace, when installed, must be electrically con- nected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United S tates. The blower power cord must be connected into a prope[...]

  • Page 5

    5 W415-0171 / D / 01.06.04 Do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth. Porcelain enamelled compo- nents must be handled with care. The baked-on finish is glasslike. If struck, it will chip! T ouch-up p aint is available through your Napoleon dealer . Levelling the insert will eliminate rocking or excessiv[...]

  • Page 6

    6 W415-0171 / D / 01.06.04 Remove the se- curing screws lo- cated on either of the firebox sides as illustrated. Remove protective plastic wrap from all four panels. Centre the rear brick panel against the back of the firebox. Place the left brick panel against the left side of the firebox, ensuring that it butts up to the rear panel. Excess materi[...]

  • Page 7

    7 W415-0171 / D / 01.06.04 FIGURE 10 FIGURE 1 1 POSITIONING THE LOGS IMPROPERL Y WILL CAUSE FLAME IMPINGEMENT AND CARBONING . PHAZER TM logs and charcoal embers, exclusive to Napo- leon Fireplaces, provide a unique and realistic glowing effect that is dif ferent in every installation. T ake the time to carefully position the charcoal embers for a m[...]

  • Page 8

    8 W415-0171 / D / 01.06.04 Attach the lower glass bracket. Seat the glass inside the bracket and using two screws attach the upper glass bracket, as shown. Assemble the flashing and mount to the inside of the outer shell using 4 securing screws (supplied with the louvre kit). Remove the backing of the logo supplied and place on the glass viewing ar[...]

  • Page 9

    9 W415-0171 / D / 01.06.04 With the bay chassis on a flat surface, insert the front glass (bottom first) and centred to the mitred edges of the chassis. Fit the bevelled edge of the each side glass piece tightly to either edge of the front glass. Secure the glass by bend- ing up the retainer tabs at the top and bottom. S pread and insert the spring[...]

  • Page 10

    10 W415-0171 / D / 01.06.04 If your masonry fireplace is equipped with a fresh air inlet in the floor of the firebrick chamber , the insert is able to take outside air directly into the unit through an opening in its base thereby eliminating the need to use preheated room air for combustion. The flow of air may be adjusted through the use of a damp[...]

  • Page 11

    11 W415-0171 / D / 01.06.04 3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly . (right brick p anel must be removed in order to facilitate burner removal) 4. Check to see that the pilot flame is large enough to engulf the thermopile on one leg and reaches toward the [...]

  • Page 12

    12 W415-0171 / D / 01.06.04 # P AR T NO. DESCRIPTION 1 GZ-551 REPLACEMENT BLOWER 2 W725-0036 NA TURAL GAS V AL VE C/W ADJUST ABLE REGULA TOR 2 W725-0037 PROP ANE GAS V AL VE C/W ADJUST ABLE REGULA T OR 3 W455-0004 #36 DMS NA TURAL GAS BURNER ORIFICE 3 W455-0003 #54 DMS PROP ANE GAS BURNER ORIFICE 3 W455-0013 #37 DMS NA TURAL GAS BURNER ORIFICE - HI[...]

  • Page 13

    13 W415-0171 / D / 01.06.04[...]

  • Page 14

    14 W415-0171 / D / 01.06.04 Gas piping is undersized. Pilot goes out while standing; Main burner is in 'OFF' position. - turn on all gas appliances and see if pilot flame flutters, diminishes or extinguishes, especially when main burners ignite. Monitor supply pressure. - check if supply piping size is to code. Correct all under- sized pi[...]

  • Page 15

    15 W415-0171 / D / 01.06.04 Main burner goes out; pilot goes out. A - Refer to "Main burner goes out; pilot stays on" B - Chimney down-drafting - wait ten minutes. Shut off all exhaust fans in the house (ie: kitchen and bathrooms), furnace, and clothes dryer . Open windows and/or doors. Start fireplace and monitor its operation. Close doo[...]

  • Page 16