Napoleon Fireplaces GDI-30N manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces GDI-30N, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces GDI-30N one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces GDI-30N. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Napoleon Fireplaces GDI-30N should contain:
- informations concerning technical data of Napoleon Fireplaces GDI-30N
- name of the manufacturer and a year of construction of the Napoleon Fireplaces GDI-30N item
- rules of operation, control and maintenance of the Napoleon Fireplaces GDI-30N item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces GDI-30N alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces GDI-30N, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces GDI-30N.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces GDI-30N item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 W415-0384 / D / 09.13.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca GAS-FIRED DIRECT VENT INSERT INST ALLA TION AND OPERA TION INSTRUCTIONS FOR: VENTED GAS FIR[...]

  • Page 2

    2 W415-0384 / D / 09.13.05 WARNING • The fireplace insert is a vented gas-fired heater . Do not burn wood or other materials in this fireplace insert. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when [...]

  • Page 3

    3 W415-0384 / D / 09.13.05 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-f[...]

  • Page 4

    4 W415-0384 / D / 09.13.05 cle. The grounding prong must not be removed from the cord plug. FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane. Maximum inlet gas pressure is 7 in[...]

  • Page 5

    5 W415-0384 / D / 09.13.05 WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result. Pro vide adequate v entilation air . Provide adequate accessibility clearance for ser vicing and operating the fireplace inser t. Never obstruct the front opening of the fire- place inser t. Objects placed in front of the fire[...]

  • Page 6

    6 W415-0384 / D / 09.13.05 FIGURE 2 Move the insert close to its final position inside the wood- burning fireplace. This unit is equipped with 4 levelling screws located in the four inside corners beneath the log support. Level using the levelling screws to eliminate rock- ing or excessive noise when the fan is in operation. Once the unit is level,[...]

  • Page 7

    7 W415-0384 / D / 09.13.05 T ABS FINISHING Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner . Fine dust found in the bottom of the bag should not be used. T ear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 & [...]

  • Page 8

    8 W415-0384 / D / 09.13.05 Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before clos- ing the door . Allow sev eral minutes (5-15) f or the flame to stabilize after ignition. Do not operate the main burner of the in- sert with the door opened. When lit for the first time, the fireplace will emit a [...]

  • Page 9

    9 W415-0384 / D / 09.13.05 7. Depress slightly and hold gas knob while lighting the pilot with the push button ignitor . Keep knob depressed for one minute, then release. If pilot does not continue to burn, re- peat steps 3 through 7. 8. With pilot lit, depress and turn gas knob counter-clock- wise to on. 9. If equipped with flame adjustment valve,[...]

  • Page 10

    10 W415-0384 / D / 09.13.05 FIGURE 9 BLOWER ACCESS COVER 1. Turn off the electri- cal power and the gas supply to the fireplace insert. 2. Open the glass door and remove the logs and fibre bricks, if in- stalled. 3. Remove the blower access cover held on with 4 screws. 4. Remove the blower mounting plate with the blower attached. NOTE: Check the bl[...]

  • Page 11

    11 W415-0384 / D / 09.13.05 # P ART # DESCRIPTION 1 GZ552 REPLACEMENT BLOWER 2 W725-0035 NA TURAL GAS V AL VE 2 W725-0026 PROP ANE GAS V AL VE 3 W455-0019 #43 NA TURAL GAS BURNER ORIFICE 3 W455-0003 #54 PROP ANE GAS BURNER ORIFICE 4 W357-0001 PIEZO IGNITER 5 W680-0004 THERMOPILE 6 W680-0005 THERMOCOUPLE 7 W010-0801 NA TURAL GAS PILOT ASSEMBL Y 7 W0[...]

  • Page 12

    12 W415-0384 / D / 09.13.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.[...]

  • Page 13

    13 W415-0384 / D / 09.13.05 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot flame. - replace pilot assembly . - clean thermopile and thermopile connection to va[...]

  • Page 14

    14 W415-0384 / D / 09.13.05 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion chamber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned. - open air shutter to increase the primary air . - check the[...]

  • Page 15

    15 W415-0384 / D / 09.13.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name[...]

  • Page 16

    16 W415-0384 / D / 09.13.05 NO TES[...]