NAPCO MAGNUM 825 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of NAPCO MAGNUM 825, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of NAPCO MAGNUM 825 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of NAPCO MAGNUM 825. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of NAPCO MAGNUM 825 should contain:
- informations concerning technical data of NAPCO MAGNUM 825
- name of the manufacturer and a year of construction of the NAPCO MAGNUM 825 item
- rules of operation, control and maintenance of the NAPCO MAGNUM 825 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of NAPCO MAGNUM 825 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of NAPCO MAGNUM 825, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the NAPCO service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of NAPCO MAGNUM 825.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the NAPCO MAGNUM 825 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    0 1880, NAPCO OPERATING GUIDE FOR YOUR MAGNUM ALERT-825/ MAGNUM ALERT-825HS SECURITY SYSTEM NAPCO[...]

  • Page 2

    Please read this guide thoroughly to familiarize yourself with your new security system. Keep this booklet handy for future reference. Note especially the ALARM PLAN on page 15. Your alarm specialist will help you fill it out and explain the various features and operating procedures for your new Magnum Alert-825/825HS. NOTICE You’ll probably find[...]

  • Page 3

    Abort Delay A delay period that allows the system to be reset before it reports to a central station. Alarm Plan ldentifies the areas of your premises pro- tected by each zone of protection and lists zone features. (See page 15) Ambush Code A one or two-digit code used before an arm/ disarm code that causes a silent report to be sent to a central s[...]

  • Page 4

    lndicator Lights ARMED/MEMORY (Red) l Steady- system is armed. l Flashes - alarm condition. Flashes indicate the number of zone(s) which were violated. (see page 5, Key 2) STATUS (Green) l Steady - system is disarmed, all zones okay. l Flashes - a non-24 hour zone is in trouble. Flashes indicate the number of the zone(s) that are in trouble. Note: [...]

  • Page 5

    Keys NOTICE:Keys1 , 2,3,4,5,9 and S must be held down for 2 seconds (until mini-sounder beeps) to per- form their desianated ‘Hold- Down " (“Key”) functions. Key 1: TEST Momentarily sounds the burglar alarm from the battery. If no alarm is heard, or if it is weak, the battery may need replacing. Use this test weekly. (To perform this fun[...]

  • Page 6

    Your Magnum Alert-825/825HS Security System has three basic components: 1. Zones Your system is capable of monitoring up to six separate areas of your premises, including Am- bush/Panic and Auxiliary zones. Each zone is an independent cir- cuit that protects a specific area of your premises. For example: your alarm specialist may have set aside a z[...]

  • Page 7

    The Digit-Key Keypad All security system operations are carried out at the keypad. Each key hasaspecialfunction o f its own (see “CONTROLS” page 5) plus the ability to arm and disarm the system when they are used in a preselected combination (codes). Personal ( Arm/Disarm) Codes You can choose up to4 four-digit codes which will allow you to arm[...]

  • Page 8

    Checking AC Power If the three lights of your keypad are blinking slowly, you have lost AC power. Check to see if there has been a general power outage, or if the Control Center’s trans- former is disconnected. If you must operate without AC power, press Key9 to stop the lights from blink- ing. Next, test your standby battery by pressing Key 1. I[...]

  • Page 9

    If trouble is encountered on a zone programmed as a Priority- with-Bypass Zone however, enter your code to silence th e Mini- Sounder and disarm; hold down Reset Key 9 until it beeps (this will bypass the alarm condition); then enter your code to rearm. Disarming When You Return When you enter through the exit/ entry door, the Mini-Sounder will com[...]

  • Page 10

    Arming Wlth Selective Zone Shunting Your alarm specialist may have opted for one or more zones that can be selectively shunted (removed) from the system. Since a shunted zone cannot cause an alarm, you may wish to use this feature to turn OFF the interior areas while arming, and keeping your perimeter zones (windows, doors, etc.) active. To arm, ch[...]

  • Page 11

    Your Alarm Specialist may have programmed your security system to be monitore d by a central station. The built-in digital communicator can transmit emergency signals to the central station 24 hours a day. EMERGENCY SERVICES (Police, Medical Etc) MONITORS YOUR SYSTEM 24 HOURS PR PREMISES ALERT-825/825HS COMMUNICATOR 11[...]

  • Page 12

    Abort Delay Note which zones on your alarm plan have abort delay. This is a delay that enables you to reset the system before a zone condition report is sent to the central station. Non-24 hour zone reports are aborted by arming and then disarm- ing. 24 hour zones, however, must first be repaired. Opening and Closing Reporting An optional feature t[...]

  • Page 13

    The following information is applicable only where local ordinance permits use of your alarm Control Center for fire detection Controlling Your Fire Circuit If your alarm specialist installed smoke detectors or heat sensing thermostats, you have 24 hour fire protection. This optional Fire Pro- tection Zone is always active, even though your system [...]

  • Page 14

    Even with the most advanced fire alarm system, adequate protection requires an escape plan. To pre- pare your plan: Draw floorplans of your building. Show two exit s - a front or back door and a window from each room. (Make sure the window works. You may need a special fire escape ladder if the window is high up.) Write down your outside meeting pl[...]

  • Page 15

    Zone Area Protected Zone Features Contacts (doom, wlndows, etc.) 1 6 Central Station (Optional) Service Person Telephone Telephone 15[...]