Mustang Survival MD1250 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mustang Survival MD1250, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mustang Survival MD1250 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mustang Survival MD1250. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mustang Survival MD1250 should contain:
- informations concerning technical data of Mustang Survival MD1250
- name of the manufacturer and a year of construction of the Mustang Survival MD1250 item
- rules of operation, control and maintenance of the Mustang Survival MD1250 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mustang Survival MD1250 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mustang Survival MD1250, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mustang Survival service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mustang Survival MD1250.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mustang Survival MD1250 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MD12 50 T A CTIC AL INFLA T ABLE SIDE POUCH LP[...]

  • Page 2

    DO NO T REMO VE PRIOR T O S ALE Warning: This document is for the use of licensed users only . No part of this document may be reproduced, transmitted, or transcribed in any form or by any means without the express permission of Mustang Survival Corp. While every effort possible has been made to ensure technical accuracy , information within this d[...]

  • Page 3

    C ONTENTS Introduction ................................................................................................... 1 Product Familiarization and Readiness ....................................................... 2 Readiness Checklist ......................................................................... 3 W earing the LP .................[...]

  • Page 4

    INTRODUCTION This manual provides instructions and guidelines for safely using and maintaining Mustang Survival MD1250 T actical Inflatable Side Pouch Life Preservers (LPs). The MD1250 LP provides flotation capability with minimum bulk or interference using separate, independently operated left and right LPs. The MD1250 LP has been designed specifi[...]

  • Page 5

    PRODUCT F AMILIARIZA TION AND READINESS The MD1250 T actical Inflatable Side Pouch LPs are used in right/left pairs, and can be attached to an LE belt, or integrated P ALS webbing and MOLLE vest. Right-hand LPs have the letter R on the attachment webbing straps (Figure 2); left-hand LPs have the letter L. Figure 1 shows the front of a right-hand LP[...]

  • Page 6

    R eadiness Checklis t If the inflat or expiry date has p assed, Must ang Survival r ecommends wat er te sting the MD1250 LP t o become familiar with it s in-wat er functionality . When all boxes are checked, the LP is ready for use: F Status indicator is green. F Inflator expiry date has not passed. F Fabric, straps, and hardware are free from defe[...]

  • Page 7

    2. Release the attachment webbing straps on the back of the LP by pulling up on each strap just below the bottom edge of the pull-the-dot snap. 3. Feed the attachment webbing straps on the back of the LP through the P ALS webbing. 4. Reattach the pull-the-dot snaps by pushing down on the top edge of the snap opposite the dot. INFLA TING THE LP W AR[...]

  • Page 8

    4. Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place. DONNING THE INFLA TED LP Once the LPs have been inflated through manual, automatic, or oral inflation, tuck the inflated cells underneath each arm (Figure 6). Attach the left and right cells together using the V elcro?[...]

  • Page 9

    4. Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place. 5. Complete repacking of the LP – see Repacking the LP . RE - ARMING THE LP CA UTION: The MD 12 50 LP must be deflat ed befor e being re-armed. 1. Open the zippers completely , wipe off any water , and place the LP o[...]

  • Page 10

    12. Ensure that the status indicator on the replacement inflator cap is green, the lanyard for the beaded manual inflation handle is present, and the locking ring is locked. 13. T o test for leakage, inflate the LP using the oral inflator tube – see Inflating the LP . T o avoid damage to the LP do not exceed 2 psi. After two hours there should be[...]

  • Page 11

    10. Ensure the bladder fabric is wrapped tightly around the CO 2 cylinder and the hydrostatic inflator (Figures 14–16). 11. Remove the vacuum fitting from the oral inflation tube. 12. Detach the automatic/manual conversion cap (MA7219) from the hydrostatic inflator . The pressure within the bladder should increase as some gas enters through the w[...]

  • Page 12

    Final P acking 1. Ensure the opening in the cover fabric is secured around the hydrostatic inflator . The water inlet valve should be easily accessible. 2. Secure the beaded handle to the LP cover using the snaps at the base of the unit. MAINT AINING THE LP Before each use, review the Readiness Checklist – see Product Familiarization and Readines[...]

  • Page 13

    • Visually inspect the expiry date on the hydrostatic inflator . If the expiry date has passed, replace the inflator – see Re-arming the LP . T esting f or Leak s Perform this test every 180 days, or more frequently if the LP is exposed to extreme conditions. 1. Orally inflate the LP until it is firm to the touch, and let it stand for two ho[...]

  • Page 14

    T esting the A utomatic In flat or NO TE: A left/ right pair of fully armed MD12 50 LPs and t wo MA7 214 -10 re- arm kits are requir ed for this t est. 1. Attach the LPs to the left and right sides (see W earing the LP). 2. Enter water of an appropriate depth to keep the head above the surface. 3. When submerged in water , the hydrostatic manual/au[...]

  • Page 15

    A CCE SS ORIES MA7214-10 Re-Arm Kit: 33 gram CO 2 replacement cylinder and inflator cap (two kits required for each pair of MD1250 LPs) MA7219 Auto/Manual Conversion Cap GLOSSARY T erm Definition LP Life preserver MOLLE Modular Lightweight Load-carrying Equipment P ALS Pouch Attachment Ladder System psi Pounds per square inch T actical Inf latable [...]

  • Page 16

    Mustang Survival and seahorse design is a register ed trademark of Mustang Survival Corp. Our commitment to quality has earned our Bur naby facilities ISO 9001 registration, the highest of all international standards. This is our guarantee you are r eceiving the ultimate in design and manufacturing. HT -1250 (Rev . 08Aug2012) F or 40 year s Mustang[...]