Multi-Link AD-600 manual

1
2
3
4
5
6
7
8
9

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Multi-Link AD-600, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Multi-Link AD-600 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Multi-Link AD-600. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Multi-Link AD-600 should contain:
- informations concerning technical data of Multi-Link AD-600
- name of the manufacturer and a year of construction of the Multi-Link AD-600 item
- rules of operation, control and maintenance of the Multi-Link AD-600 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Multi-Link AD-600 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Multi-Link AD-600, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Multi-Link service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Multi-Link AD-600.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Multi-Link AD-600 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    AD-600 Installation Guide[...]

  • Page 2

    Installation Guide AD-600 General Information The main panels of the AD-600 are made of polypropy lene and are 2.36”(6 CM) in height. Cable trench caps are made of steel. Quick and easy installation is a strong advantage of the ConnectFloor systems. AD-600 compromises one of the most unique, cost effective, and easily installed low-profile floors[...]

  • Page 3

    2. Starting Line – laying instructions To maximize usage of full panels at the borders, it is recom mended that you select the longest walls or the entrance wall as starting point. Note: Properly selecting the starting line is import ant. It saves labor time and materials. Other factors that may affect choice of the star ting line include: door, [...]

  • Page 4

    3. Installation a. Apply Sound Attenuation Blanket. Spray adhesive, duct tape, or 3M adhesive tape may be used to hold down the sound blanket to the sub floor. b. Old carpet or resilient floor to substitute Sound Attenuation Bla nket: For retrofit installation over existing commercial rated low-pile carpet, carpet tile , PVC tile and sheet vinyl, s[...]

  • Page 5

    grid of cable trench every 23.62”(60 CM) on center. (Drawing D609) Accessible Cable Trench - Clearance: 2.24”(57 mm) Width: 3.54”(90 mm) To assemble a module of 23.63” X 23.63”( 60 cm X 60 cm) coverage requires: 1 UniPanel + 1 Central Cap + 1 Base Connector + 4 Flank Caps D609 D610 f. UniPanel : The main component of AD- 600 system is the[...]

  • Page 6

    installation or service. (Drawing D609) Note: This ease eliminates fr equent coordination conflicts between trades. Instead of the contractors converging on job sites attempting to achieve opposite results (caps on/caps off, cables down/ cables up), the electrical contractor can r out e and lay the cables after the installation of ConnectFloor is c[...]

  • Page 7

    facilitated by using sections of Wall Rail cut to length with a scroll saw and set down perpendicular to the edge of the last irregularly laid ConnectFl oor part. The sections’ varying lengths are carefully measured so that they will fill up the entire space between the wall and the ConnectFloor that is already installed. l. End Caps are used to [...]

  • Page 8

    These following pieces of trim may be used in cases where the edge of the flooring does not butt completely up against the wall. The UniPanels, as me ntioned in previous sections, can also be cut to meet up against the wall to finish the flooring matrix. (1) When the residual space is less than 2.36”(6 cm) in width : Use Edge Rail (AD-623). Faste[...]

  • Page 9

    8 E-Mail: engsupport@multilinkbroadband.com Web: www.multilinkbroadband.com 580 Ternes Avenue P.O. Box 955 Elyria, OH 44035 Phone: 440.366.6966 Fax: 440.366.6802 24 Hour Voice Messaging Worldwide Distribution[...]