MRV Communications EM316E3 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of MRV Communications EM316E3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MRV Communications EM316E3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of MRV Communications EM316E3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of MRV Communications EM316E3 should contain:
- informations concerning technical data of MRV Communications EM316E3
- name of the manufacturer and a year of construction of the MRV Communications EM316E3 item
- rules of operation, control and maintenance of the MRV Communications EM316E3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MRV Communications EM316E3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MRV Communications EM316E3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MRV Communications service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MRV Communications EM316E3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the MRV Communications EM316E3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EM316E3 EM316E3SF E3 Fiber Modem Fiber Driver Module User’s Guide[...]

  • Page 2

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 2 Registration Card Your name: Mr./Ms____________ _______________________________ Organization: _________________ _______Dept. __________________ Your title at organization:__ __________________ __________________ Telephone: _____________ ______________ Fax:__________________ Organiz[...]

  • Page 3

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 3 EM316E3 EM316E3SF E3 Fiber Modem Fiber Driver Module User’s Guide[...]

  • Page 4

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 4 TABLE OF CONTENTS 1 INTRODUCTION 2 HARDWARE INSTALLATION 3 TROUBLESHOOTING 4 TECHNICAL SPECIFICATIONS 5 CONTACT INFORMATION 6 GLOSSARY 7 ORDERING INFORMATION[...]

  • Page 5

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 5 1 INTRODUCTION About this Manual Before unpacking please refer to section 2 (Hardware Installation) This manual is a guide to the installati on and operation of the EM316E3 Fiber modem. Product description describes the product, it s functions, features, protocol supported, minimum[...]

  • Page 6

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 6 Features • E3 conversion between coax media and fiber media • Supports ITU-T G.703, ITU-T G.823, and HDB3 standards • Supports Local, Remote and Line Loop back Test • Up to 100km Transmission on Single Mode or 7km on Multimode Fiber • Modules can be Inserted / Removed wit[...]

  • Page 7

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 7 Display Information (LED Definition) • PWR: illuminates when unit is powered (green colo r) • LPBK: illuminates (yellow color) when loca l loop back o n both interfaces is enabled, OFF (no light or green color) when in normal mode • C: illuminates when E3 (coax) interface det[...]

  • Page 8

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 8 Configuration Jumper Settings: (Factory Default) CONFIGURING THE SWITCH (S1) SWITCH SETTINGS RESULTS *ON Force switches selections (loop back) regard less of NMS command MAN/NMS OFF Default setting comes from switches afte r power up, but maybe change by NMS commands SEC/PRI ON/OFF[...]

  • Page 9

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 9 Theory of Operation Block diagram of the Modem/Converter is shown below (fig. 1) Fig. 1 Block Diagram of EM316DS3 E3 Line Receiver to fiber optic Transmitter : The receiver Line Interface Unit (LIU) receives the E3 signal an d performs clock recovery and data detection. The data go[...]

  • Page 10

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 10 Switch LPBK/NORM is set to OFF Switch LPBK/NORM is set to OFF Loop Back Control: By NMS command or manually by a switch Loop back can be forced regardless of management by turning switch 1 MAN/NMS to ON and switch 3 NORM/LPBK to ON. NOTE: It is also possible to configure an extern[...]

  • Page 11

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 11 2 HARDWARE INSTALLATION PREP ARA TION STEP 1 Follow all Safety Regulations 1 Eliminate static electricity in the workplace by grounding operators, equipment, and devices (components and computer boards). Groundi ng prevents static charge buildup and electrostatic potential differe[...]

  • Page 12

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 12 f) ESD protective floor or mat: The mat must be grounded through a current- limiting resistor. The floor or mat dissip ates the static charge of personnel approaching the workbench. Special conduc tive tile or floor treatment can be used when mats are not practical or cau se a saf[...]

  • Page 13

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 13 UNIT INSTALLATION STEP 1 Remove required amount of bla nk panels from the NC316BU-xx. NOTE : Per FCC regulations, either a panel or a module should always cover chassis slots. FIGURE 1.1 Take out the required amount of blank panels. STEP 2 Align the edges of the EM316 module to th[...]

  • Page 14

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 14 STEP 3 Insert the module into the NC316BU-xx unit NOTE: To avoid dam aging any components on the m odule, handle it by the edges, using your thumb to push it securely inside the ch assis. Do not use excessive force, but make sure the module is fully inserted in the chassis. W hen [...]

  • Page 15

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 15 3 TROUBLESHOOTING The Fiber Driver series are highly reliable units. If there are any operating problems, the fault probably lies in some other aspect of the configuration. However, if after following the troubl eshooting steps below (in order), you find that the unit is still not[...]

  • Page 16

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 16 4 TECHNICAL SPECIFICATIONS Electrical 5VDC @ 2 Amps Max Hot Swappable Operating Temperature Range 0 ° C - +50 ° C (32 ° F – 122 ° F) Storage temp -10 ° C - +60 ° C (14 ° F – 140 ° F) Relative Humidity 85% maximum non-condensing Emissions Compliance FCC Part 15, Subpart[...]

  • Page 17

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 17 5 CUSTOMER SUPPORT Contact Information If you have any questions, please do not hesitate to contact us at: Americas Support MRV (East Coast USA) 295 Foster Street Littleton, MA 01460-2016 Tech Support: (800) 338-5316 Tech Support: (978) 952-4700 E-mail: support@fiberdriver.com Fax[...]

  • Page 18

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 18 5 GLOSSARY Complete definition of networking term s (jargon) used in this manual, may be found on our ftp site: ftp://ftp.fiberdriver.com/pub/doc/Glossary.pdf 6 ORDERING INFORMATION Please visit us at http://www.fiberdriver.com for the latest updates on our products. Fiber Driver [...]

  • Page 19

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 19 Place Stamp Here ---------- -------- -------- ---------- -------- ---- ---------- -------- -------- ---------- -------- ---- ---------- -------- -------- ---------- -------- ---- 8928 Fullbright Avenue Chatsworth, California 91311 U . S . A .[...]