Monessen Hearth WR400 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Monessen Hearth WR400, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Monessen Hearth WR400 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Monessen Hearth WR400. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Monessen Hearth WR400 should contain:
- informations concerning technical data of Monessen Hearth WR400
- name of the manufacturer and a year of construction of the Monessen Hearth WR400 item
- rules of operation, control and maintenance of the Monessen Hearth WR400 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Monessen Hearth WR400 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Monessen Hearth WR400, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Monessen Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Monessen Hearth WR400.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Monessen Hearth WR400 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

            For use in U.S./Canada Underwriter's Laboratories Report No. MH6018 ?[...]

  • Page 2

    2 WR / W C Series W oodbur ning Fireplace 20014528        Read all instructio[...]

  • Page 3

    3 WR / W C Series W oodbur ning Fireplace 20014528 5/8" (16mm) 1/2" (13mm) 1/2" 36" (914mm) 38 56M " (971mm) 40" (1016mm) 5/8" (16mm) 22 6M " (578mm) 1 6M " (45mm) 35 56O " (902mm) 24" (610mm) 7 6M " (197mm) 7 56O " (191mm) Recessed Nailing Flange FP590 SC36 SPECS 10/28/98 1 [...]

  • Page 4

    4 WR / W C Series W oodbur ning Fireplace 20014528 5/8" (16mm) 1/2" (13mm) 1/2" 42" (1067mm) 38 56M " (971mm) 46" (1 168mm) 5/8" (16mm) 22 6M " (578mm) 1 6M " (45mm) 38" (965mm) 24" (610mm) 7 6M " (197mm) 7 56O " (191mm) Recessed Nailing Flange FP592 SC42 SPECS 10/02 1 1"[...]

  • Page 5

    5 WR / W C Series W oodbur ning Fireplace 20014528  Insulation methods shown are optional for cold climate, not a requirement for unit operation. FP554  Fireplace and chase parts identification. FP554 BR/BC Combo of IWF261 AND IWF265 11/10/97 T ermination Cap Storm Collar Pan F[...]

  • Page 6

    6 WR / W C Series W oodbur ning Fireplace 20014528  0 0 0 0 0 3" 1 1" 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 1 1 ¹⁄₄ " 25 ¹⁄₄ " 2 0 0 0 0 13 ¹⁄₂ " 29 ¹⁄₄ " 1 1 0 0[...]

  • Page 7

    7 WR / W C Series W oodbur ning Fireplace 20014528 L 1 L 1 L T MODEL SK 2 W ALL CHIMNEY TOT AL LENGTH (L T ) INST ALLED LENGTH (L 1 ) SK81 SK818 SK83 SK84 1 1 56O " 17 56O " 35 56O " 47 56O " 10 56O " 16 56O " 34 56O " 46 56O " FP288 MBUF-INST ALLED LENGTH 6/17/96  Installed lengths of[...]

  • Page 8

    8 WR / W C Series W oodbur ning Fireplace 20014528   If you live in a cold climate, it is not required but  that you insulate fireplace enclosure to eli[...]

  • Page 9

    9 WR / W C Series W oodbur ning Fireplace 20014528  Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace spe[...]

  • Page 10

    10 WR / W C Series W oodbur ning Fireplace 20014528  T o mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9 ¹⁄₄ " (235mm). Mark a spot on the ceiling directly above the fireplace. Draw a line p[...]

  • Page 11

    1 1 WR / W C Series W oodbur ning Fireplace 20014528  Safety strips are not required over noncom- bustible floors where all supports at the base of the fireplace are noncombustible. Four (4) nailing flanges are incorporated on each cor- ner of the surround. Bend the nailing flanges out, level the box, then secure it firmly in p[...]

  • Page 12

    12 WR / W C Series W oodbur ning Fireplace 20014528 Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer .   A fir[...]

  • Page 13

    13 WR / W C Series W oodbur ning Fireplace 20014528  In the U.S., it is a good idea, although not al- ways required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic. Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corne[...]

  • Page 14

    14 WR / W C Series W oodbur ning Fireplace 20014528     Follow the installation instructions provided with the chimney termination you have selected.  R[...]

  • Page 15

    15 WR / W C Series W oodbur ning Fireplace 20014528 MA81 rev . 8/5/97 1 56O " Ref. Combustible materials are permitted within a shaded area shown in Figure 23 titled Minimum W all Clearances. * ** MA81  Combustible mantle clearances. [...]

  • Page 16

    16 WR / W C Series W oodbur ning Fireplace 20014528  A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for mini- mum dimensions and mounting detail. ?[...]

  • Page 17

    17 WR / W C Series W oodbur ning Fireplace 20014528 COMMON MA TERIALS AND F ACTORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (MHSC) R V alue is for 1/2 inch. * Units of K = BTU/SQ FT/HR /˚F/IN ** Thickness of Listed Material FP533ADD Addendum 6/1/99 djt 8/4/99 changed .2 to .1 one inch to 1/2 in[...]

  • Page 18

    18 WR / W C Series W oodbur ning Fireplace 20014528  MHSC fireplaces are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.) Be sure to have the app[...]

  • Page 19

    19 WR / W C Series W oodbur ning Fireplace 20014528 1 2 3 4 5 a b c 6 7 8 9 10 948 SR/SC parts 5/16/00 djt d 12 1 1 e MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.  [...]

  • Page 20

    20 WR / W C Series W oodbur ning Fireplace 20014528 The following accessories for this appliance are available from your local MHSC distributor . Should you need addi- tional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361, Attn: T echnical Services. ?[...]

  • Page 21

    21 WR / W C Series W oodbur ning Fireplace 20014528  Round T op T ermination T op used to terminate chimney at roof. RL TSK8 (Flashing not included.) Round T op T ermination - T op used to terminate chimney at chase. RL TSK8L Extended (Flashing not included.) Flashing Metal finishing required ar[...]

  • Page 22

    22 WR / W C Series W oodbur ning Fireplace 20014528 Chimney Collar Enclosure Installs on the "over the chimney collar" of the CCE-SK fireplace; provides outside air to assist in cooling the chimney system. Attic Insulation Shield Used to prevent insulation from coming in AIS-SK contact with the chimney system. SK8 Chimney Sections Used to[...]

  • Page 23

    23 WR / W C Series W oodbur ning Fireplace 20014528     [...]

  • Page 24

     149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com 20014528 10/08 Rev . 2[...]