A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Monessen Hearth LCUF32-F, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Monessen Hearth LCUF32-F one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Monessen Hearth LCUF32-F. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Monessen Hearth LCUF32-F should contain:
- informations concerning technical data of Monessen Hearth LCUF32-F
- name of the manufacturer and a year of construction of the Monessen Hearth LCUF32-F item
- rules of operation, control and maintenance of the Monessen Hearth LCUF32-F item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Monessen Hearth LCUF32-F alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Monessen Hearth LCUF32-F, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Monessen Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Monessen Hearth LCUF32-F.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Monessen Hearth LCUF32-F item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    For use with a listed gas-fired unvented decorative room heater not to exceed 40,000 BTU/hr . Do not build a wood fi re. READ AND SA VE THESE INSTRUCTIONS W ARNINGS If the information in this manual is not followed exactly , a fi re or explosion may result causing property damage, personal injury or loss of life. – Do not store or use gasoline [...]

  • Page 2

    2 26D4721 CONTENTS Important Safety Information ................................. 3 Product Features ......................................................5 Before Y ou Start .....................................................5 General Installation Information .............................6 Firebox External Dimensions ............................[...]

  • Page 3

    26D4721 3 9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54. 10. This unit complies with ANSI Z21.91 ventless firebox enclosures for gas-fired unvented decorative room heaters. 11. Do not install heater in a bathroom or bedroom. 12. Correct installation of the lo[...]

  • Page 4

    4 26D4721 IMPORT ANT SAFETY INFORMA TION Continued from page 3 16. Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids. 17. Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appli- ance. 18. Unvented gas heaters emit moisture into the living are[...]

  • Page 5

    26D4721 5 The LCUF32-F and LCUF36C-R are vent-free fireboxes. They feature a self contained heat-circulating system. This instal- lation manual will enable you to obtain a safe, efficient and dependable installation of your vent-free firebox system. Do not alter or modify the firebox or its components under any circumstances. Any modification or al[...]

  • Page 6

    6 26D4721 In planning the installation for the appliance it is necessary to determine where the unit is to be installed and whether optio nal accessories are desired. Gas supply piping should also be planned. The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequen[...]

  • Page 7

    26D4721 7 MINIMUM HEARTH DIMENSIONS GENERAL INST ALLA TION INFORMA TION AND LOCA TION OF FIREBOX Figure 2 - Minimum Hearth Dimensions LOCA TION OF FIREBOX Carefully select the best location for installation of your vent-free firebox. The following factors should be taken into consideration: • Clearance to side wall, ceiling, woodwork and windows.[...]

  • Page 8

    8 26D4721 6" Minimum 42" Minimum 6" Minimum Ensure that minimum clearances shown in Figures 4 through 7 are maintained. Left and right clearances are determined when facing the front of the firebox. Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a fire hazard. 1. Sidew[...]

  • Page 9

    26D4721 9 12" 10" 8" 6" 2 1 / 2 " 12" 16" 19" 21" 23" Combustible material can contact top of fi replace. Non-combustible material only if needed to cover radiant top face above FIREPLACE W ALL COMBUSTIBLE MA TERIAL AREA HOOD T OP VIEW Figure 8- Mantel Clearances CLEARANCES AND HEIGHT REQUIREMENTS [...]

  • Page 10

    10 26D4721 FIREBOX FRAMING H G D F E A C B A 1 / 2 "o r 5 / 8 " C A G C G A Firebox framing can be built before or after the appliance is set in place. Construct fi rebox framing following Figur es 9 thr ough 12 and the chart below for your speci fi c installation requirements. See Figur e 1 on Page 6 for fi rebox dimensions. The frami[...]

  • Page 11

    26D4721 11 K J FIREBOX FRAMING 1. Bend out the nailing flanges located on each side of the firebox. 2. Slide the firebox into prepared framing or position firebox in its final position and frame later. 3. Level the firebox by checking the top edge of the firebox. Shim if necessary. 4. Anchor firebox to the side framing members using 8d nails or oth[...]

  • Page 12

    12 26D4721 GAS LINE INST ALLA TION Consult all local codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA54. The 1 / 2 " gas line may enter either from the left side or right side of the firebox. Gas access holes are provided[...]

  • Page 13

    26D4721 13 CANOPY INST ALLA TION INST ALLING CANOPY A canopy is furnished with each firebox and MUST be installed for safe operation. See Figure 15. 1. Remove the three (3) screws from the top front frame assembly. Also remove the two (2) screws on the side frames. See Figure 15. 2. Align the canopy with the holes in the top frame. 3. Replace the s[...]

  • Page 14

    14 26D4721 4 2 1 3 OPTIONAL EQUIPMENT AND ILLUSTRA TED P ARTS LIST OPTIONAL WIDE CANOPY The optional wide canopy can be installed. See installation instructions provided with kit. ITEM DESCRIPTION QTY LCUF32-F LCUF32-R LCUF36C-R 1 Canopy 1 71D0023 71D0023 71D0500 2 Screen Panel 2 070942 070942 26D4563 3 Screen Rod 2 26D0138 26D0138 26D0132K ACCESSO[...]

  • Page 15

    26D4721 15 USING OPTIONAL AK-4 OUTSIDE AIR KIT 8'max. COMBUSTION AIR 1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner . Locate assembly a minimum of 12" above the snow line to prevent blockage by snow accumulation. 2. Never mount the combustion air inlet assembly in a g[...]

  • Page 16

    16 26D4721 USING OPTIONAL AK-4 OUTSIDE AIR KIT The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fi replace. Use the model AK4 combustion air kit. MODEL AK-4 COMBUSTION AIR ASSEMBL Y 1. Remove the cover plate from the 4" outlet opening [...]

  • Page 17

    26D4721 17 MODEL AK-4 COMBUSTION AIR ASSEMBL Y (CONTINUED) 7. If the duct is the insulated type, push the insulation back from one end of the duct approximately 2". See Figur e 23. 8. Slip the exposed end of the duct over the starting collar on the fi replace . 9. Using the sheet metal screws provided, secure the duct end to the collar attach[...]

  • Page 18

    MA Y 2008 P/N 26D4721 • Rev . 10 MONESSEN HEARTH SYSTEMS LIMITED LIFETIME W ARRANTY POLICY The following components are warranted for life to the original owner, subject of proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate, and Stainless Steel Burners. FIVE YEAR W ARRANTY The following components are warranted for 5 years to t[...]