Mitsubishi Electronics R22 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics R22, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics R22 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics R22. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsubishi Electronics R22 should contain:
- informations concerning technical data of Mitsubishi Electronics R22
- name of the manufacturer and a year of construction of the Mitsubishi Electronics R22 item
- rules of operation, control and maintenance of the Mitsubishi Electronics R22 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics R22 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics R22, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics R22.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics R22 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SPLIT -TYPE AIR CONDITIONERS Natural Comfor t For Ever ybody POWER CEILING CASSETTE W ALL MOUNTED CEILING SUSPENDED CEILING CONCEALED R2 2[...]

  • Page 2

    P RODUCT LI N E-U P 2.5 hp 3 hp P KH-F AK W all mount ed PCH-GAK Ceiling suspended OUTDOOR U N IT P LH-A AK P ower ceiling cassett e P EH-EAK Ceiling concealed PCH-3GAK PLH-3A AK PEH-3EAK PEH-2.5EAK PU H-2.5AK A PU H-3VK A*/PU H-3YK A PKH-3F AK 1 *PU H-3VKA is only for P EH series.[...]

  • Page 3

    4 hp 5 hp 6 hp P. 7 P. 8 P. 9 P. 1 0 Remote controller Contents PCH-4GAK PCH-5GAK PCH-6GAK PLH-4A AK PLH-5A AK PLH-6A AK PEH-5EAK P EH-6EAK PEH-4EAK PU H-4YKS A P U H-5YK SA PUH-6YKSA PKH-4F AK 2 Optional[...]

  • Page 4

    Mitsubishi Electric Offers Three Impor tant A dvantages In today’s competitive environment, simply meeting industry standards, however stringent, is not enough. Our aim is to exceed them. That’s why when it comes to comfor t, efficiency and durability: Mitsubishi Electric offers you a distinctive advantage. We call it MEQ — Mitsubishi Electri[...]

  • Page 5

    Multi-language Display Weekly T imer The function of the weekly timer equipped can change the set temperature in addition to the ON/OFF control. Up to 8 pat- terns can be set for each calendar day . Whatever your requirements may be, Mitsubishi Electric offers advanced split-type heat pumps per fect for any interior , any need. Significantly decrea[...]

  • Page 6

    Control function System configuration Necessary parts & equipment ■ Timer adapter P AC-SE55RA-E (connect to CN32 on indoor circuit board) ■ Relay box (on-site) ■ MAC-397IF-E (one for each outdoor unit) ■ Additional remote controller (option) ■ Remote controller cord (on-site) — ■ Timer adapter P AC-SE55RA-E (connect to CN32 on ind[...]

  • Page 7

    Stylish wireless remote controller with all the latest programming features Wireless remote controller for PLH-AAK Mr . SLIM Convenient Remote Controller ● FAN SPEED SE LECT button Used to change fan speed. ● VANE CONTROL button Used to change airflow direction. ● MODE SE LECTION button Used to select operating modes — Cool, Dry , and Heat,[...]

  • Page 8

    Design uniformity improves installation flexibility From the smallest 3HP unit to the largest 6HP model, the new high- power ceiling cassettes offer a uniformly square 950 x 95 0mm width and depth design. Thanks to the uniformity of the panel size, planning for unit positioning in any room is enhanced and the installation of dif- ferent capacity mo[...]

  • Page 9

    8 IN DEX Specifications .........................................p.1 1 Option ......................................................p.1 3 PKH -F AK SERIES PKH-3F AK P KH-4F AK Auto-flap shutter When the unit is turned off , the shutter closes automatically over the air outlet to enhance the stylish design. The shutter also functions as a flap to ad[...]

  • Page 10

    Direct suspension with attachment fixture attached 1. Leave attachment fixture attached to main unit. 2. Suspend the attachment fixture from the suspension bolts. 3. Simply tighten the nuts to secure the unit. Ceiling surface Suspension bolts Air outlet Attachment fixture Extra slim, extra stylish Sleek and slim with stylishly curved lines, the PCH[...]

  • Page 11

    10 CEILI NG CONCEALED Limitless installation possibilities Offering all the benefits of split-type models plus other important advantages, the PEH-EAK Series is not only easy to install but also very versatile. For example, the distance between the air-intake and air-out- let vents can be varied to allow airflow to be positioned in the opti- mum lo[...]

  • Page 12

    P LH-A AK PO WER CEI LI NG CAS SETTE SPECIF IC A TION S 11 Models PLH-3AAK PLH-4AAK PLH-5AAK PLH-6AAK Function Heating W 7,700 16,100 Capacity T otal input kW 3.32 4.51 4.46 5.07 4.92 COP W/W 2.32 2.75 3.14 2.76 3.27 Model name PLH-3AAK PLH-4AAK PLH-5AAK PLH-6AAK External finish Galvanized sheets with gray heat insulation Power supply Airflow ( Lo-[...]

  • Page 13

    12 SPECIF IC A TION S P EH-EAK CEI LI NG CONCEALED PCH-GAK CEI LING SUSP EN DED s l e d o M GAK 3 - H C P GAK 4 - H C P GAK 5 - H C P 6GAK - H C P n o i t c n u Fg n i l o o Cg n i t a e Hg n i l o o Cg n i t a e Hg n i l o o Cg n i t a e Hg n i l o o Cg n i t a e H y t i c a p a CW 0 0 6 , 70 0 5 , 80 0 0 , 0 10 5 4 , 0 10 0 4 , 2 10 0 9 , 3 10 0 [...]

  • Page 14

    13 GEN ERAL SP ECIF ICACIONS FOR ALL MODELS ■ Main Optional Parts l e d o M n o i t p i r c s e Ds l e d o m e l b a c i l p p A D A 5 2 7 - C A P ) s t e s 0 1 ( r e t p a d A r e l l o r t n o C e t o m e R e l p i t l u M New A/K control P AC-SE55RA-E Timer Adapter New A/K control MAC-397IF-E MA & Control T erminal Interface New A/K contro[...]

  • Page 15

    14 ■ When used in rooms with high ceilings, it is recommended that a ceiling fan or circulator be installed to improve air cir culation and temperature variations within the room. ■ The remote-control cir cuits under microprocessor control r emain on at all times whether the air conditioner is or is not in operation. For more economical operati[...]

  • Page 16

    HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Mitsubishi Electric Shizuoka Works acquired ISO 900 1 certification under Series 9000 of the International Standard Organization (I SO) based on a review of Quality warranties for the production of refrigeration and air conditioning equipment. Mitsubishi Electric Shizuok[...]