Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA should contain:
- informations concerning technical data of Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA
- name of the manufacturer and a year of construction of the Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA item
- rules of operation, control and maintenance of the Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics PUZ-HA30NHA PUZ-HA36NHA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TECHNICAL DA T A BOOK CONTENTS 1. REFERENCE SERVICE MANUAL ············································· 2 2. SPECIFICA TIONS ······································································ 3 3. OUTLINES AND DIMENSIONS ····?[...]

  • Page 2

    2 For information on service, please refer to the service manual as follows. 1-1. INDOOR UNIT Service Manual No. OCH426 OCB426 1-2. OUTDOOR UNIT Model name Service Ref. PUZ-HA30/36NHA PUZ-HA30/36NHA Model name Service Ref. Service Manual No. PLA-A18/30/36BA PLA-A18BA PLA-A18BA 1 OCH420 OCB420 PKA-A18GA PKA-A18GA/GA 1 /GA 2 OC369 PKA-A18GAL PKA-A18G[...]

  • Page 3

    3 2 SPECIFICA TIONS Model name Indoor unit PLA-A36BA PKA-A36FA(L) Outdoor unit PUZ-HA36NHA PUZ-HA36NHA Cooling Max. Capacity BTU/h 36,000 34,200 Rated Capacity BTU/h 36,000 34,200 Min. Capacity BTU/h 18,000 18,000 Total Input W 3,120 2,950 EER BTU/h/W 11.5 11.6 SEER BTU/h/W 16.0 16.0 Moisture Removal Pints/h 6.8 7.1 *1 SHF 0.79 0.77 Heating Max. Ca[...]

  • Page 4

    4 4 INDOOR UNIT Unit : inch (mm) PLA-A18BA PLA-A30BA PLA-A36BA 3 OUTLINES AND DIMENSIONS 14-27/32 1 1-3/16 2-3/8 +5 0 (7.5) +35 -5 (160) (500) (950) Floor Min.94-1/2(2400) from floor Entire peripher y (36) (83) (83) (36) (500) (950) (597) (597) ( 158) ( : 175) (350) ( : 150) ( 14- : 2.8 ) (167) (155) (130) (100) (90) (90) (100) (100) (35) (17 ) +3/[...]

  • Page 5

    5 5 PKA-A18GA PKA-A18GAL Unit : inch (mm) Drain hose  Gas pipe  Liquid pipe MODEL 18 1/4 1/2 3/16(5) 1(25) 1-1 1/32(34) 1-5/16(33) Air intake Air intake Lower side 22-7/8(581) 17-1 1/16(449) Knockout hole for right piping Refrigerant pipe.Drain pipe. Wiring hole  Gas pipe  Liquid pipe (Necessary clearance for Unit installation) Filter g[...]

  • Page 6

    6 PKA-A30F A PKA-A30F AL Unit : inch (mm) Drain hose 5/8 3/8 24/30 MODEL 15/16(24) 1-5/16(34) 1-7/16(36) 1 Wiring entrance holes T erminal block T erminal block Knockout hole for right piping 1-31/32(50) or more 9-27/32(250) or more 9-27/32(250) or more 1-3/16(30) or more Less than 9-27/32(250) 3-19/32(91) 8-27/32(225) 7-1/4(184) 1-3/16(30) 9-7/16([...]

  • Page 7

    7 PKA-A36F A PKA-A36F AL Unit : inch (mm) Drain hose 15/16(24) 1-5/16(34) 1-7/16(36) 1-31/32(50) or more 9-27/32(250) or more Less than 5-29/32(150) 9-27/32(250) or more 1-3/16(30) or more Less than 9/16(15) 1 1-5/8(295) 8-27/32(225) 1-3/16(30) 7-1/4(184) 9-7/16(240) 7-3/32(180) 11-1/32(280) 12-3/8(314) 23/32(18) 23/32(18) 3-5/32(80) 1/2*3-19/32=(4[...]

  • Page 8

    8 PUZ-HA30NHA PUZ-HA36NHA Unit : mm<inch> Min. 1000mm <39-3/8> Min. 150mm <5-29/32> Min. 10mm <3/8> Min. 10mm <3/8> FREE <Foundation bolt height> FOUNDATION Service space Terminal Block Left···Power supply wiring Right····Indoor/Outdoor wiring Earth terminal Service panel Handle 1 2 23<29/32> 1076<[...]

  • Page 9

    9 4 WIRING DIAGRAM PLA-A18BA PLA-A30BA PLA-A36BA <T able 2>SW2(CAP ACITY CODE) Service PLA-A30BA PLA-A36BA PLA-A42BA PLA-A12BA PLA-A18BA PLA-A24BA MODELS SW2 ON OFF 12345 Service MODELS ON OFF 12345 ON OFF 12345 ON OFF 12345 ON OFF 12345 ON OFF 12345 <T able 1>SW1(MODEL SELECTION) Service SW1 ON OFF 12345 SYMBOL SYMBOL NAME NAME I.B IND[...]

  • Page 10

    10 PKA-A18GA PKA-A18GAL Please set the voltage using the remote controller . For the setting method, please refer to the indoor unit Installation Manual. INT AKE CN20 ( RED ) LIQUID CN21 ( WHT ) PIPE CN29 ( BLK ) TH5 TH1 TH2 REMOCON CN22 ( BLU ) TB5 R.B TRANSMISSION WIRES DC12V For A12/18GAL For A12/18GA SWE ON OFF SW2 SW1 LED3 LED2 LED1 ZNR FUSE C[...]

  • Page 11

    11 PKA-A30F A PKA-A30F AL PKA-A36F A PKA-A36F AL SW1 Table 1 Service board SW2 Table 2 Service board Service board Service board 1 2 3 4 5 ON OFF 1 2 3 4 5 ON OFF MODELS PKA- A24FA(L) MODELS PKA- A30FA(L) MODELS PKA- A36FA(L) 1 2 3 4 5 ON OFF 1 2 3 4 5 ON OFF Please set the voltage using the remote controller. For the setting method, please refer t[...]

  • Page 12

    12 1234567 8 MODEL SW6 + 1MODEL SELECT + 2. SW5 -1 to 5: Function Switch SW5-6 + 2 OFF ON 30N OFF ON 123456 TB1 MC MF1, MF2 21S4 63H TH3,TH32,TH33 TH4 TH6 TH7 TH8 LEV-A, LEV-B,LEV-C DCL Terminal Block<Power Supply, Indoor/Outdoor > Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) High Pressure Switch SV 63L Low Pressure Switch S[...]

  • Page 13

    13 5-1. INDOOR UNIT PLA-A·BA PKA-A·GA PKA-A·GAL PKA-A·F A PKA-A·F AL Thermistor TH2 Pipe temperature (Liquid) Distributor with strainer(#50) Thermistor TH5 (Cond./Eva. temperature) Thermistor TH1 (Room temperature) Refrigerant flow in cooling Refrigerant flow in heating Strainer(#50) Strainer(#50) Heat exchanger Refrigerant GAS pipe connection[...]

  • Page 14

    14 6 PERFORMANCE CUR VES Note : This diagram shows the case where the operation frequency of a compressor is fixed. FOR THE COMBINA TION OF OUTDOOR UNIT PUZ-HA·NHA 1.4 1.2 1.0 0.8 72°F (22°C) 72°F (22°C) 68°F (20°C) 68°F (20°C) 64°F (18°C) 64°F (18°C) 61°F (16°C) 61°F (16°C) 90 (32°C) 70 (21°C) 50 (10°C) 30 (-1°C) 23 (-5°C) 11[...]

  • Page 15

    15 Rated heating performance curve Rated heating capacity 0.50 1.00 1.50 2.00 80 ˚ F (27 ˚ C) 70 ˚ F (21 ˚ C) 60 ˚ F (16 ˚ C) 60 ˚ F (16 ˚ C) 70 ˚ F (21 ˚ C) 80 ˚ F (27 ˚ C) Outdoor ambient temp. INPUT (RATIO) CAPACITY (RATIO) 0.60 0.80 1.00 1.20 1.40 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 -26 -23 -21 -18 -15 -12 -9 -7 -4 -1 2 [...]

  • Page 16

    16 7 CORRECTION F ACT ORS Refrigerant piping length (one way) 30m (100ft) 40m (130ft) 50m (165ft) 55m (180ft) 60m (195ft) 70m (230ft) 80m (260ft) 20m (70ft) 10m (33ft) 5m (16ft) Outdoor unit PUZ-HA30NHA PUZ-HA36NHA 1.00 0.985 0.957 0.931 0.908 0.886 0.876 0.865 0.846 0.829 Refrigerant piping length (one way) 30m (100ft) 40m (130ft) 50m (165ft) 55m [...]

  • Page 17

    17 7-4. ADDITION OF REFRIGERANT • Additional charging is not necessary if the pipe length does not exceed 30 m (100 ft). • If the pipe length exceeds the specified length above, charge the unit with additional R410A refrigerant according to the permitted pipe lengths in the chart below . * When the unit is stopped, charge the unit with the addi[...]

  • Page 18

    18 8 AIR FLOW DA T A 8-1. OUTLET AIR SPEED AND COVERAGE RANGE CFM ft/sec.(m/sec.) ft (m) Airflow Air speed Coverage range PLA-A30BA 740 12.1 (3.7) 18 (5.6) PLA-A36BA 1060 17.4 (5.3) 26 (8.0) 640 10.5 (3.2) 15 (4.8) PLA-A18BA PKA-A18GAL PKA-A18GA 425 17.4 (5.3) 33 (10) CFM ft/sec.(m/sec.) ft (m) Airflow Air speed Coverage range CFM ft/sec.(m/sec.) f[...]

  • Page 19

    19 8-2. PLA-A·BA 8-2-1 FRESH AIR INT AKE AND BRANCH DUCT 1. Branch duct hole and fresh air intake hole (Fig. 1) At the time of installation, use the duct holes (cut out) located at the positions shown in Fig.1, as and when required. • A fresh air intake hole for the optional multi function casement can also be made. Note: The figure marked with [...]

  • Page 20

    20 2 - inlet 1 - inlet 2 - inlet 1 - inlet 2 - inlet 1 - inlet -200(-80) -150(-60) -100(-40) -50(-20) 0 50(20) 01 2 50 100 150 200 [CFM] 34 5 6 [CMM] 2 - inlet 1 - inlet Airflow rate Airflow rate Static pressure [Pa(in.W.G. % 10 -2 )] -200(-80) -150(-60) -100(-40) -50(-20) 0 50(20) 01 2 50 100 150 200 [CFM] 34 5 6 [CMM] Static pressure [Pa(in.W.G. [...]

  • Page 21

    21 Indoor unit Air outlet shutter plate (Option) Outlet concave portion Button Button V a ne motor V a ne motor Up/down vanes Connector Connector 4. Change of outlet numbers The optional air outlet is necessary . T o change the air outlet number to 3-, or 2-way outlet, the outlet number should be closed with the operational air outlet shutter . Whe[...]

  • Page 22

    22 4-way airflow (horizontal vane) Round duct 4-way airflow (horizontal vane) Rectangular duct 3-way airflow (horizontal vane) Round duct 3-way airflow (horizontal vane) Rectangular duct 2-way airflow (horizontal vane) Round duct • Use 1 of the 2 duct holes on the indoor unit. • Use the optional air outlet shutter plate (P AC-SH51SP-E) for 3-wa[...]

  • Page 23

    23 4-way airflow (horizontal vane) Round duct High High Low Duct Duct Low 3-way airflow (horizontal vane) Round duct 3-way airflow (horizontal vane) Rectangular duct High Low High Low Duct Duct Close Close • Use 1 of the 2 duct holes on the indoor unit. • Use the optional air outlet shutter plate (PAC-SH51SP-E) for 3-way and 2-way airflow. Clos[...]

  • Page 24

    24 PLA-A18B A NO TCH SPL(dB) LINE High 32 Medium1 31 Medium2 29 Low 28 OCT A VE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 bar) 90 80 70 60 50 40 30 20 10 63 125 250 500 1000 2000 4000 8000 APPRO XIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-60 NC-50 NC-40 NC-30 NC-20 NC-70 BAND CENTER FREQUENCIES, Hz NOISE CRITERION CUR VES 9 PLA-A36B A NO[...]

  • Page 25

    25 90 80 70 60 50 40 30 20 10 63 125 250 500 1000 2000 4000 8000 APPROXIMA TE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-60 NC-50 NC-40 NC-30 NC-20 NC-70 PKA-A18GA PKA-A18GAL High NOTCH Medium1 Medium2 Low 43 SPL(dB) 41 38 36 LINE OCT A VE BAND SOUND PRESSURE LEVEL, dB (0dB= 0.0002 bar ) BAND CENTER FREQUENCIES, Hz UNIT WA L L 3.3ft 3.3ft MICROPH[...]

  • Page 26

    26 90 80 70 60 50 40 30 20 10 63 125 250 500 1000 2000 4000 8000 APPROXIMA TE THRESHOLD OF HEARING FOR CONTINUOUS NOISE OCT A VE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 bar) BAND CENTER FREQUENCIES, Hz NC-60 NC-50 NC-40 NC-30 NC-20 NC-70 PUHZ-HA30NHA PUHZ-HA36NHA COOLING MODE HEA TING 52 SPL(dB) 53 LINE 5 ft 3.3 ft MICROPHONE UNIT GROUND 9-2. [...]

  • Page 27

    27 10 OPTIONAL P ARTS 10-1. INDOOR UNIT Part Name Model Name Applicable model Remote sensor (extensible) PAC-SE41TS-E Connector for CN51 (output for remote display + pulse12V input) PAC-88HA-E(1pc.) PAC-725AD(10pcs.) Power supply terminal kit PAC-SH55HR-E PAC-SH98HR-E PLA-A·BA PKA-A·GA(L)/FA(L) All models Connector for CN32 (remote ON/OFF) PAC-SE[...]

  • Page 28

    10-2. OUTDOOR UNIT FOR PUZ-HA30/36NHA Part Name Model Name M-NET adapter PAC-SF80MA-E A-control service tool PAC-SK52ST Drain socket PAC-SG61DS-E Air outlet guide(HA30/36 needs 2 pieces.) PAC-SG59SG-E Air protect guide(HA30/36 needs 2 pieces.) PAC-SH63AG-E Drain pan PAC-SG64DP-E Distribution pipe for twin use MSDD-50SR-E HEAD OFFICE : TOKYO BLDG., [...]