Mitsubishi Electronics PKA-RP-KAL manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics PKA-RP-KAL, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics PKA-RP-KAL one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics PKA-RP-KAL. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsubishi Electronics PKA-RP-KAL should contain:
- informations concerning technical data of Mitsubishi Electronics PKA-RP-KAL
- name of the manufacturer and a year of construction of the Mitsubishi Electronics PKA-RP-KAL item
- rules of operation, control and maintenance of the Mitsubishi Electronics PKA-RP-KAL item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics PKA-RP-KAL alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics PKA-RP-KAL, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics PKA-RP-KAL.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics PKA-RP-KAL item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    [...]

  • Page 2

    2 Contents 1. Safety Precautions 2. Parts Names  PKA-RP·KAL Filter Air inlet Air outlet Louver Va n e  Before installing the unit, make sure you read all the “Safety Precautions”.  The “Safety Precautions” provide very important points regarding safety . Make sure you follow them.  Please report to or take consent by the supply[...]

  • Page 3

    3  Wired Remote-Controller °F°C °F°C ERROR CODE AFTER TIMER TIME SUN MON TUE WED THU FRI SA T ON OFF Hr AFTER FIL TER FUNCTION ONL Y1Hr . WEEKL Y SIMPLE A UTO OFF P AR-21MAA ON/OFF FIL TER CHECK OPERA TION CLEAR TEST TEMP . MENU BACK D A Y MONITOR/SET CLOCK ON/OFF Down Up Back Ahead Opening the door . T o preceding operation number . T o nex[...]

  • Page 4

    4  Wireless Remote-Controller  Outdoor unit Power Earth Service Panel Indoor-Outdoor Connection wire Ref. Pipes 2. Parts Names T ransmission indicator T imer indicator  When using the wireless remote controller , point it towards the receiver on the indoor unit.  If the remote controller is operated within approximately two minutes afte[...]

  • Page 5

    5 Note: The day and time will not appear if clock use has been disabled at Function Selection of remote controller . Day of the Week & T ime display °C °C TIME SUN P AR-21MAA ON/OFF FIL TER CHECK OPERA TION CLEAR TEST TEMP . MENU BACK DA Y MONITOR/SET CLOCK ON/OFF 2 4 9 1 a T ime Setting TIME SUN 2 3 4 Day of the Week Setting 4. Setting the D[...]

  • Page 6

    6 5. Operation <T o Stop Operation>  Press the ON/OFF button 1 again. • The ON lamp 1 and the display area go dark. Note: Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about three minutes. This is to prevent the internal components from being damaged.[...]

  • Page 7

    7 5.5. Airflow up/down direction setting <T o change the airflow up/down direction>  With the unit running, press the Airflow up/down button 6 as necessary . • Each press changes the direction. The current direction is shown at 6 . • The change sequence, and the available settings, are as follows. Airflow Wireless remote controller Swi[...]

  • Page 8

    8 6.1. For Wired Remote-controller Y ou can use Function Selection of remote controller to select which of three types of timer to use: 1 Weekly timer , 2 Simple timer , or 3 Auto Off timer . 6.1.1. Weekly Timer  The weekly timer can be used to set up to eight operations for each day of the week. • Each operation may consist of any of the foll[...]

  • Page 9

    9 6.1.2. Simple Timer  Y ou can set the simple timer in any of three ways. • Start time only: The air conditioner starts when the set time has elapsed. • Stop time only: The air conditioner stops when the set time has elapsed. • Start & stop times: The air conditioner starts and stops at the respective elapsed times.  The simple tim[...]

  • Page 10

    10 TIMER ON OFF Hr AFTER SIMPLE 1 6 5 T imer Setting °C °C SIMPLE 7 °C °C ON Hr AFTER SIMPLE 7 6. Timer ON Hr AFTER SIMPLE °C °C OFF Hr AFTER SIMPLE SIMPLE At 3 hours after timer start Display changes to show the timer’s OFF setting (hours remaining to OFF). The time displayed is OFF setting (7 hours) – ON setting (3 hours) = 4 hours. At [...]

  • Page 11

    11 <Checking the Current Auto Off Timer Setting> 1. Be sure that the “Auto Off” is visible on the screen (at 1 ). 2. Hold down the T imer Menu button b for 3 seconds , so that “Monitor” is indicated on the screen (at 4 ). • The timer remaining to shutdown appears at 5 . 3. T o close the monitor and return to the standard control scr[...]

  • Page 12

    12 7.2. Error Codes indication ON/OFF ERROR CODE  If the ON lamp and error code are both flashing: This means that the air conditioner is out of order and operation has been stopped (and cannot resume). T ake note of the indicated unit number and error code, then switch off the power to the air conditioner and call your dealer or servicer . Indo[...]

  • Page 13

    13 [Function selection flowchart] Setting language (English) OFF on1 on2 OFF ON OFF ON OFF OFF CALL- ON OFF ON OFF C F PAR-21MAA ON/OFF FILTER CHECK OPERA TION CLEAR TEST TEMP . MENU BACK DA Y MONITOR/SET CLOCK ON/OFF F E G C D H B A I G G G G G G E E G G G G G E G E G G G G D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D English German[...]

  • Page 14

    14 [Detailed setting] [4]–1. CHANGE LANGUAGE setting The language that appears on the dot display can be selected. • Press the [ MENU] button G to change the language. 1 English (GB), 2 German (D), 3 Spanish (E), 4 Russian (RU), 5 Italian (I), 6 Chinese (CH), 7 French (F), 8 Japanese (JP) Refer to the dot display table. [4]–2. Function limit [...]

  • Page 15

    15 [Dot display table] Selecting language English Germany Spanish Russian Italy Chinese French Japanese W aiting for start-up Operation mode Cool Dry Heat Auto Auto(Cool) Auto(Heat) Fan V entilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) T est run Self check Unit function selection Setting of ventilatio[...]

  • Page 16

    16 X Filter removal Caution: • In removing the filter , precautions must be taken to protect your eyes from dust. Also, if you have to climb up on a stool to do the job, be careful not to fall. • When the filter is removed, do not touch the metallic parts inside the indoor unit, otherwise injury may result.  PKA-RP·KAL 1 Using both hands, p[...]

  • Page 17

    17 1 1. T roubleshooting Having trouble? Here is the solution. (Unit is operating normally .) Air conditioner does not heat or cool well.  Clean the filter . (Airflow is reduced when the filter is dirty or clogged.)  Check the temperature adjustment and adjust the set temperature.  Make sure that there is plenty of space around the outdoor[...]

  • Page 18

    18 Having trouble? Here is the solution. (Unit is operating normally .) Noise is louder than specifications.  The indoor operation sound level is af fected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room. High sound- absorbing rooms N[...]

  • Page 19

    [...]

  • Page 20

    Please be sure to put the contact address/telephone number on this manual before handing it to the customer . HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Printed in Thailand RG79D344H01[...]