Mitsubishi Electronics MS-GA50VB manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics MS-GA50VB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics MS-GA50VB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics MS-GA50VB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsubishi Electronics MS-GA50VB should contain:
- informations concerning technical data of Mitsubishi Electronics MS-GA50VB
- name of the manufacturer and a year of construction of the Mitsubishi Electronics MS-GA50VB item
- rules of operation, control and maintenance of the Mitsubishi Electronics MS-GA50VB item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics MS-GA50VB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics MS-GA50VB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics MS-GA50VB.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics MS-GA50VB item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SPLIT -TYPE AIR CONDITIONERS OPERA TING INSTRUCTIONS INDOOR UNIT MS-GA50VB MS-GA60VB MS-GA80VB MSH-GA50VB MSH-GA60VB MSH-GA71VB MSH-GA80VB For customers Thank you very much for purchasing this Mitsubishi room air conditioner . • T o use this unit correctly and safely , be sure to read this operating instructions before use. Keep this manual caref[...]

  • Page 2

    2 AIR OUTLET • This air conditioner is NOT intended for use by children or infirm persons without supervisions. Do not use intermediate connection of the power supply cord or the extension cord and do not connect many devices to one AC outlet. • A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissib[...]

  • Page 3

    3 MU-GA60VB MUH-GA60VB MUH-GA71VB MU-GA80VB MUH-GA80VB MU-GA50VB MUH-GA50VB Operation Indicator WIDE & LONG AIR FLOW SAFETY PRECAUTIONS For installation Do not use the unit for special purposes. • Do not use this air conditioner to preserve precision devices, food, animals, plants and art objects. This may cause deterioration of quality , etc[...]

  • Page 4

    4 ON/OFF FAN TO O WAR M TO O COOL VANE MODE ECONO COOL STOP START HR. MIN. WIDE VANE LONG I FEEL COOL HEAT DRY AMPM CLOCK ˚ C AMPM RESET CLOCK MODE I FEEL COOL DRY FAN ON/OFF TO O COOL AMPM CLOCK ˚ C AMPM TOO WARM AMPM CLOCK ˚ C AMPM Signal transmitting section Operation display section T emperature buttons (This diagram shows an overall view .)[...]

  • Page 5

    5 Operation Indicator Operation Indicator Operation Indicator Operation Indicator Operation Indicator ON/OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR. MIN. I FEEL COOL DRY AMPM CLOCK ˚ C AMPM WIDE VANE LONG HEAT RESET CLOCK Handling of the remote controller • The range that the signal can reach is about 6 m when the remote contro[...]

  • Page 6

    6 Indication Operation state Difference between target temperature and room temperature This shows that the air conditioner is operating to reach the target temperature. Please wait until the target temperature is obtained. About 2°C or more This shows that the room temperature is approaching the target temperature. About 2°C or less (In case of [...]

  • Page 7

    7 ON/OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR. MIN. I FEEL COOL DRY AM PM CLOCK ˚ C AMPM WIDE VANE LONG HEAT RESET CLOCK ON/OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR. MIN. I FEEL COOL DRY AM PM CLOCK ˚ C AMPM WIDE VANE LONG HEAT RESET CLOCK Horizontal AIR FLOW blowing range NOTE: Ad just t he ho riz ont al A[...]

  • Page 8

    8 ON/OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR. MIN. I FEEL COOL DRY AM PM CLOCK ˚ C AMPM WIDE VANE LONG HEAT RESET CLOCK ON/OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR. MIN. I FEEL COOL DRY AM PM CLOCK ˚ C AMPM WIDE VANE LONG HEAT RESET CLOCK T o release the LONG mode: ■ Press the LONG button again. ■ LONG[...]

  • Page 9

    9 MAINTENANCE Before starting maintenance ■ T urn off the breaker and/or disconnect the power supply plug. CAUTION: When the unit is to be cleaned, switch it off and discon - nect the power supply plug or turn off the breaker . Since the fan rotates at high speed during operation, it may cause an injury . Cleaning the indoor unit ■ Clean the un[...]

  • Page 10

    10 3 Aft er washi ng with wat er/lu kewar m water , dry the air filter well in the shade. • Do not expose the air filter to direct sunlight or heat from a fire when drying it. 4 Install the air filter . 1 Remove the air filter . CAUTION: When the air filter is to be removed, do not touch the metal parts of the indoor unit. This may cause an[...]

  • Page 11

    1 1 BEFORE CONT ACTING THE SERVICE REPRE- SENT A TIVE, CHECK THE FOLLOWING AGAIN WHEN YOU THINK THA T TROUBLE HAS OCCURRED Even if the above items are checked, when the air conditioner does not recover from the trouble, stop using the air conditioner and consult your dealer . In the following cases, stop using the air conditioner and consult your d[...]

  • Page 12

    12 wall, etc. Keep a space to prevent the picture distortion or the noise. 1 m or more Radio 100 mm or more Well- ventilated dry place TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets, radios, etc. In areas where the rece ption is weak[...]

  • Page 13

    SG79Y755H01 HEAD OFFICE: T OKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN SG79Y755H01_COVER.indd 2 4/21/06 5:13:09 PM[...]