Mitsubishi Electronics J71UC24 manual

1
2
3
4
5

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics J71UC24, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics J71UC24 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics J71UC24. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsubishi Electronics J71UC24 should contain:
- informations concerning technical data of Mitsubishi Electronics J71UC24
- name of the manufacturer and a year of construction of the Mitsubishi Electronics J71UC24 item
- rules of operation, control and maintenance of the Mitsubishi Electronics J71UC24 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics J71UC24 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics J71UC24, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics J71UC24.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics J71UC24 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Series HMI Connection Manual Mitsubishi A Series/J71UC24 Computer Link HMI Factory Setting: Baud rate: 9600, 8, ODD, 1 Controller Station Number: 0 ( Note 1 ) Control Area / Status Area: D0/D10 Connection a. RS-232 (DOP-A/AE/AS, DOP-B Series) 108 V1.02 Revision November, 2011 DOP Series 9 pin D-sub male (RS-232) Controller RXD (2) (3) TXD TXD (3) ([...]

  • Page 2

    Series HMI Connection Manual c. RS-422 (DOP-AS35/AS38/AS57 Series) V1.02 Revision November, 2011 109 DOP Series Controller 9 pin D-sub male (RS-422) R- SDB R+ SDA T+ RDA d. RS-422 (DOP-B Series) DOP Series 9 pin D-sub male (RS-422) Controller RXD- (9) SDB RXD+ (4) SDA TXD+ (1) RDA e. RS-485 (DOP-A/AE Series) DOP Series 9 pin D-sub male (RS-485) Con[...]

  • Page 3

    Series HMI Connection Manual f. RS-485 (DOP-AS57 Series) 110 V1.02 Revision November, 2011 DOP Series 9 pin D-sub male (RS-485) Controller RDA g. RS-485 (DOP-AS35/AS38 Series) h. RS-485 (DOP-B Series) DOP Series 9 pin D-sub male (RS-485) Controller RDA D+ (1) SDA RDB D- (6) SDB DOP Series 9 pin D-sub male (RS-485) Controller R+ RDA T+ SDA R- SDB R+[...]

  • Page 4

    Series HMI Connection Manual Definition of PLC Read/Wri te Address a. Registers V1.02 Revision November, 2011 111 Format Type Word No. (n) Read/Write Range Data Length Note X n X 0 – X 7FF Input Word 3 Y n Y 0 – X 7FF Output Word 3 B n B 0 – B FFF Link Relay Word 3 M n M 0 – M 8176 Internal Relay Word 3 SM n SM 9000 – SM 9240 Special Inte[...]

  • Page 5

    Series HMI Connection Manual b. The mode switch setting of AJ71UC24- R4 communication is 8 (Form 4), station number can be determined by switch setting X1/X10. After PLC communication mode switch is set, please re-activate the PLC. The protocol is CheckSum and PLC Mode is Form 4. For switch setting of other communication parameter, please re fers t[...]