MGE UPS Systems 1500C manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of MGE UPS Systems 1500C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MGE UPS Systems 1500C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of MGE UPS Systems 1500C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of MGE UPS Systems 1500C should contain:
- informations concerning technical data of MGE UPS Systems 1500C
- name of the manufacturer and a year of construction of the MGE UPS Systems 1500C item
- rules of operation, control and maintenance of the MGE UPS Systems 1500C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MGE UPS Systems 1500C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MGE UPS Systems 1500C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MGE UPS Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MGE UPS Systems 1500C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the MGE UPS Systems 1500C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    51031998EN/AA - Page 1 Installation and user manual Pulsar EX treme CLA 1500C www .mgeups.com MGE UPS SYSTEMS[...]

  • Page 2

    Page 2 - 51031998EN/AA Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar EX treme range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the en[...]

  • Page 3

    51031998EN/AA - Page 3 Safety Safety of persons Safety rules When the batteries are connected to the UPS, the outlets may be energised even if the UPS is disconnected from the AC input source. Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. The UPS must be properly earthed. Measur[...]

  • Page 4

    Page 4 - 51031998EN/AA Foreword Using this document Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Information may be found primarily by consulting: ◗ the contents, ?[...]

  • Page 5

    51031998EN/AA - Page 5 Contents 1. Presentation 1.1 Pulsar EX treme range ................................................................................................................. 7 T ower model .................................................................................................................................... 7 Rack model .[...]

  • Page 6

    Page 6 - 51031998EN/AA Contents 3.4 Personalisation (optional) ........................................................................................................... 22 Function ........................................................................................................................................ 22 "ON / OFF conditions&q[...]

  • Page 7

    51031998EN/AA - Page 7 1. Presentation 1.1 Pulsar EX treme range Tower model Rack model EX1000 Rack Dimensions in mm (H x W x D) 235.5 x 145 x 505 Weight in kg 9.5 Dimensions in mm (H x W x D) 88 (2U) x 482.6 x 493 Weight in kg 12.5[...]

  • Page 8

    Page 8 - 51031998EN/AA RS232 USB 1 2 1. Presentation 1.2 Back slot for communications-card option. RS232 communications port. USB communications port. four outlets for direct connection of protected equipment. input circuit breaker. socket for connection to AC-power source. connector for battery connection. pushbutton to test phase/neutral inversio[...]

  • Page 9

    51031998EN/AA - Page 9 1. Presentation Rack model slot for communications-card option. RS232 communications port. USB communications port. four outlets for direct connection of protected equipment. input circuit breaker. socket for connection to AC-power source. 1 2 3 4 6 7 8 10 9 11 connector for battery connection. pushbutton to test phase/neutra[...]

  • Page 10

    Page 10 - 51031998EN/AA 100% 80% 50% 20% test % % 1 2 bypass 1.3 Control panel Alarms UPS overload. electronics fault. battery fault. hold down to display percent load: - lamp test or buzzer OFF. - forced transfer to bypass and back by pressing button 3 times in less than 5 seconds. status of programmable outlet 1: operation on bypass (no backup po[...]

  • Page 11

    51031998EN/AA - Page 11 2. Installation 2.1 Unpacking and checks two cords for connection of the protected equipment. RS 232 communications cable. USB communications cable. "UPS Driver" diskette for UPS personalisation. "Solution Pac" CD ROM. documentation. ␣ box for battery connection. 27 28 29 25 24 25 26 27 28 Tower model 2[...]

  • Page 12

    Page 12 - 51031998EN/AA 2. Installation 27 28 31 24 Rack model 24 29 ␣2 4 two cords for connection of the protected equipment. ␣2 5 RS 232 communications cable. ␣2 6 USB communications cable. ␣2 7 "UPS Driver" diskette for UPS personalisation. ␣2 8 "Solution Pac" CD ROM. ␣2 9 documentation. ␣3 0 box for battery con[...]

  • Page 13

    51031998EN/AA - Page 13 2.2 Installation of the rack version 2. Installation Rack mounting diagram with rails. The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. 1 2 3 3 3 3 4 EX1000 Rack[...]

  • Page 14

    Page 14 - 51031998EN/AA 2. Installation 2.3 Connection to the RS 232 or USB communications port (optional) 1 - Connect the RS 232 25 or USB 26 communications cable to the serial port or the USB port on the computer. 2 - Connect the other end of the communications cable 25 or 26 to the RS 232 2 or USB 3 communications port on the UPS. The UPS can no[...]

  • Page 15

    51031998EN/AA - Page 15 RS232 USB 1 2 2.4 Installation of the communications-card option It is not necessary to shut down the UPS to install the communications card: 1 - Remove the slot 1 cover secured by two screws. 2 - Insert the card in the slot. 3 - Secure the card with the two screws. Tower model Rack model Slot for the communications-card opt[...]

  • Page 16

    Page 16 - 51031998EN/AA 2. Installation 2.5 Battery connection Warning The batteries should be connected only by qualified electrical installation specialists. The work involved in connecting the batteries must be carried out in accordance with all applicable rules and regulations, respecting all safety measures for working on live equipment, i.e. [...]

  • Page 17

    51031998EN/AA - Page 17 2. Installation i j h b a d c 10 140 e 10 10 10 f g 8 Tower model 40A 12V -65Ah 40A OFF Cable and circuit-breaker not supplied 6 m max. 40 A curve C[...]

  • Page 18

    Page 18 - 51031998EN/AA 2. Installation 1 2 i j 1 2 h Rack model 1 2 c d b a 8 10 140 e 10 10 10 f g 1 2 RS232 USB 40A 12V -65Ah 40A OFF Cable and circuit-breaker not provided 6 m max. 40 A curve C[...]

  • Page 19

    51031998EN/AA - Page 19 2. Installation Connecting the UPS to the AC-input source 1 - Remove the power cord supplying the equipment. Check cord characteristics (> 250 V, 10 A, see the technical sheet). 2 - Connect the cord to the AC-power socket ␣␣7 on the UPS, then to the AC-power wall outlet. Setting the UPS for the installed battery confi[...]

  • Page 20

    Page 20 - 51031998EN/AA 3. Operation 3.1 Start-up 100% 80% 50% 20% test % % 1 2 bypass The protected equipment connected to the UPS can be energised, whether AC input power is available or not. 12 13 14 23 Caution: the AC input power source must be present when energising for the first time. Press the ON / OFF button 23 . The buzzer beeps and all t[...]

  • Page 21

    51031998EN/AA - Page 21 3. Operation 3.3 Operation on battery power (following failur e of AC input power) 1 2 bypass 1 2 bypass test % 1 2 bypass 22 Transfer to battery power The AC-power source is outside tolerances, LED 23 is ON, the buzzer beeps three times. The equipment connected to the UPS is supplied by the battery. Threshold for the low-ba[...]

  • Page 22

    Page 22 - 51031998EN/AA 3. Operation 3.4 Personalisation (optional) Function Personalisable function Automatic start Cold start (battery power) Forced shutdown Sleep mode UPS ON / OFF via software Default setting Enabled Enabled Enabled Disabled Enabled Personalisation parameters can be set and modified using the "UPS Driver" software ins[...]

  • Page 23

    51031998EN/AA - Page 23 3. Operation bypass Personalisable function Rated UPS voltage Rated UPS frequency UPS tolerance for AC-power source frequency Overload alarm threshold UPS restart following short-circuit Default setting 230 V F = 50 Hz F ± 5 % 1 10 % Disabled Options 200 V - 210 V - 220 V - 240 V 60 Hz F ± 1 % to ± 10 %, in 1 % steps 0 to[...]

  • Page 24

    Page 24 - 51031998EN/AA 4. Maintenance 4.1 T roubleshooting Indication LED 12 flashes and the buzzer beeps. LED 14 flashes. The yellow LED ␣ 15 . flashes, the red indicator light 10 behind the UPS comes on and the buzzer sounds continuously . Signification UPS overload. Overload is too long or too high. ◗ If AC power is present and within toler[...]

  • Page 25

    51031998EN/AA - Page 25 Troubleshooting requiring MGE UPS SYSTEMS after-sales support Indication LED 13 flashes and the buzzer sounds continuously. Signification UPS electronics have detected a UPS fault. Depending on the UPS personalisation parameters (see section 3.4), there are two possibilities: ◗ the equipment connected to the UPS continues [...]

  • Page 26

    Page 26 - 51031998EN/AA 5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (c[...]

  • Page 27

    51031998EN/AA - Page 27 6. Appendices 6.1 T echnical characteristics Operating conditions Relative humidity: 20 to 90 % without condensation. Temperature: 0 to 40 ° C. Simplified diagram Input voltage and frequency 160 V to 276 V +/- 5 % (at rated power) 50 Hz or 60 Hz +/- 5 % Output voltage and frequency 200* / 210 / 220 / 230 / 240 V 50 Hz or 60[...]

  • Page 28

    Page 28 - 51031998EN/AA 6. Appendices 6.2 Glossary Authorised voltage range for Upper and lower voltage thresholds within which the UPS can operate on the automatic transfer to bypass if fault or bypass in the event of a UPS fault or overload. overload Automatic bypass Automatic switch controlled by the UPS, used to connect the equipment directly t[...]

  • Page 29

    51031998EN/AA - Page 29 6. Appendices 6.3 Index A AC power Failure .................................................................... 21 Frequency tolerance ............................................... 23 Return ..................................................................... 21 Automatic start ............................................[...]

  • Page 30

    5103199800/AA MGE UPS SYSTEMS 140, Avenue Jean Kuntzmann ZIRST - Montbonnot St Martin 38334 - Saint Ismier Cedex - France www.mgeups.com Nothing will stop you now 5103199800-AA[...]