Metrologic Instruments MS1890 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Metrologic Instruments MS1890, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Metrologic Instruments MS1890 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Metrologic Instruments MS1890. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Metrologic Instruments MS1890 should contain:
- informations concerning technical data of Metrologic Instruments MS1890
- name of the manufacturer and a year of construction of the Metrologic Instruments MS1890 item
- rules of operation, control and maintenance of the Metrologic Instruments MS1890 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Metrologic Instruments MS1890 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Metrologic Instruments MS1890, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Metrologic Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Metrologic Instruments MS1890.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Metrologic Instruments MS1890 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    METROLOGIC INSTRUMENTS, INC. MS1890 Focus ® Area Imaging Bar Code Scanner Installation and User’s Guide[...]

  • Page 2

    Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any for m or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Cop yright Act of 1976. Trademarks Metrologic is a registered trademark[...]

  • Page 3

    ii T ABLE OF C ONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessori es ................................................................................. 2 Scanner Comp onents ........................................................................[...]

  • Page 4

    iii T ABLE OF C ONTENTS Upgrading the Flash ROM Firmware .................................................................. 30 Scanner and Cable T erminations Scanner Pinout Connecti ons .......................................................................... 31 Cable Connector C onfigurat ions ....................................................[...]

  • Page 5

    1 I NTRODUCTION Product Overvie w The MS1890 is a rugged, hig h performance hand- held area imagi ng bar code scanner that utilizes a high-resolution CMOS imaging sensor for superior i mage quality. The MS1890 utiliz es Omniplanar, Inc.’s S wiftdecoder ® software for reliable decoding of both 1 D and 2D bar co de symbologie s. Sharp images can b[...]

  • Page 6

    2 I NTRODUCTION Scanner and Accessories B ASI C K IT Part # Description MS1890 Area Imaging Bar Code Scanner 00-02544 MetroSelect ® Single-Line Conf iguration Guide* 00-02281 Area Imaging Bar Code Supplem ental Configur ation Guide* 00-02293 MS1890 Series Area Imaging Bar Code Scanner Installation and User’s Guide* * Available on the Metrologic [...]

  • Page 7

    3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 53-53713 x -N-3 USB Full Speed Cable Locking Plus-Power™ Type A, Black, Coiled Cord with Long Strain Rel ief 53-53714 x -N-3 USB Full Speed Cable Locking Plus-Power™ Type A, Black, Coiled Cord with Long St rain Relief, Extended Leng th This cable is for use with f[...]

  • Page 8

    4 I NTRODUCTION Scanner Components No. Item Description 1 Blue LED See Visual Indicators (on page 14) 2 White LED See Visual Indicators (on page 14) 3 Yellow LED See Visual Indicators (on page 14) 4 Red Window LED Aperture 5 Trigger See Modes of Operation (on page 12) 6 Utility Hook 7 Cable Boot See The PowerLink C able (on page 5) 8 Cable Release [...]

  • Page 9

    5 I NTRODUCTION The PowerLink Cable Connecting Important: If the Pow erLink cable is n ot fully latched, the unit can power intermittently. Figure 2. Connecting the PowerLink Cable 1. Insert the 10-pi n RJ45 end of the cable into the socket on the MS1890. There will be an audible click when the connector locks into place. 2. Gentl y pull on the cab[...]

  • Page 10

    6 I NTRODUCTION Labels Each scanner has a label loc ated on the underside of the hea d. This label provides the unit’s model number, date of manufacture, serial number, CE, and caution information. The follo wing figur e gives an example of the lab el and its location. Figure 4. Label Samples and Location Caution: To maintain compliance with appl[...]

  • Page 11

    7 I NSTALLING THE S CANNER TO THE H OST S YSTEM RS232 MS1890-14 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS1890. There will be an audible click when the connector lock engages. 3. Slide the protective cable boot up the cable, over the connector and onto the end of scanner han[...]

  • Page 12

    8 I NSTALLING THE S CANNER TO THE H OST S YSTEM Keyboard Wedge MS1890-47 1. Turn off the host device. 2. Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pi n socket on the MS1890. There will be an audible click when the connector lock engag es. 3. Slide the protective cable boot up the cable, over the connector and onto the end of scan[...]

  • Page 13

    9 I NSTALLING THE S CANNER TO THE H OST S YSTEM Stand Alone Keyboard MS1890-47 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS1890. There will be an audible click when the connector lock engages. 3. Slide the protective cable boot up the cable, over the connector and onto the end[...]

  • Page 14

    10 I NSTALLING THE S CANNER TO THE H OST S YSTEM IBM MS1890-11 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS1890. There will be an audible click when the connector lock engages. 3. Slide the protective cable boot up the cable, over the connector and onto the end of scanner handle. 4.[...]

  • Page 15

    11 I NSTALLING THE S CANNER TO THE H OST S YSTEM Integrated USB: Full Speed MS1890-40 Low Speed MS1890-38 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the MS1890. There will be an audible click when the connector lock engag es. 3. Slide the protective cable boot up the cable, over the conn[...]

  • Page 16

    12 S CANNER O PERATION Multi-Try Trigger Mode* 1. The IR detects an object in the IR activation range and automatically turns on linear illuminatio n. 2. Aim the scanner’s line of light over the bar code. 3. Pull the trigger to initiate scanning. The scanner’s light output will start to flash as it attempts to scan the bar code. If the trigger [...]

  • Page 17

    13 S CANNER O PERATION Audible Indicators When the MS1890 is in operation, it pr ovid es audible feedb ack. These sounds indicate the status of the scanner. Eight settings are availab le for the tone of the beep (normal, 6 alternate tones and no t one ). To change the tone, refer to the MetroSelect Single-Line Confi guration Guide, MLPN 00-02544 or[...]

  • Page 18

    14 S CANNER O PERATION Visual Indicators The MS1890 has three LED indic ators (yellow, white and blue) located on the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner. No LEDs are Illuminated The LEDs will not be illuminat ed if the scanner is not re[...]

  • Page 19

    15 S CANNER O PERATION Failure Modes Long Razzberry Tone – During Power Up Failed to initialize or configure the sc anner. If the scanner does not respond after reprogramming, return the scanner for repair. Short Razzberry Tone – During Scanning An invalid bar code has been scanne d when in configuration mode or th e trigger has been pulled too[...]

  • Page 20

    16 S CANNER O PERATION Depth of Field by Minimum Bar Code Element Width M INIMUM B AR C ODE E LEMENT W IDTH 1D PDF A B C D E F G mm .132 .19 .254 .33 .533 .254 .381 mils 5.2 7.5 10.4 13 21 10 15.9 Figure 12. Depth of Field by Minimum Bar Code E lement Width Specifications are subjec t to change without notice.[...]

  • Page 21

    17 S CANNER O PERATION IR Activation Range The MS1890 has a built in obj ect detection sensor that instantly turns on the scanner when an object is presented with in the scanner’s IR activatio n Area. Figure 13. IR Activation Area Specifications are subjec t to change without notice .[...]

  • Page 22

    18 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Me tro or 1- 800-436-3876 to pres erve the limited warranty terms. All Interfaces MS1890 Series Troubleshooting Gui de Symptoms Possible Causes Solution No power is being supplied to the scanner. Check transformer, outlet a[...]

  • Page 23

    19 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not beep when bar code is scanned. The beeper is disabled and no tone is selected. Enable the beeper and select a tone. The unit powers up, but does not scan and/or beep. The bar code symbology tryi ng to be scanned is not enabled. UPC/EAN, Code 39, interleave[...]

  • Page 24

    20 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The print quality of the bar code is suspect. Check print mode. The type of printer could be the problem. Change print settings (i.e. change to econo mode or high speed) . The aspect ratio of the bar code is out of tolerance. Check print mode. The type of printer could be the problem. Cha[...]

  • Page 25

    21 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit is transmitting each character twi ce. The configuration is not set correctly. Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings. Alpha characters show as lower case. The computer is in Caps Lock mo[...]

  • Page 26

    22 D ESIGN S PECIFICATIONS MS1890 D ESIGN S PECIFICATIONS O PERATIONAL Light Source: LED 645 nm Pulse Duration: 1 ms to 8 ms Maximum Output of an Osram LED: Maximum 85 mA emits 3,120 mlm Depth of Scan Field: 0 mm – 300 mm (0" – 11.81") for 0.330 mm (13 mil) Bar Code at Default Setting 49 mm W x 19 mm H (1.9" W x 0. 8" H) at [...]

  • Page 27

    23 D ESIGN S PECIFICATIONS MS1890 D ESIGN S PECIFICATIONS E LECTRICAL Input Voltage: 5.0VDC ± 0.25V Peak = 2 W (Typical) Operating = 1.65 W (Typical) Power: Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical) Operation = 330 mA (Typical) Current: Idle / Standby = 160 mA (Typical) DC Transformer: Class 2; 5.2VDC @ 1A For regulatory compliance[...]

  • Page 28

    24 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S ) 11 IBM 468X/469X, RS232-T XD, RXD, RTS, CTS 14 RS232 (TX, RX, RTS, CTS, DTR) 38 Low Speed US B 40 Full-speed USB MS1890 - 47 Keyboard Wed ge, Stand-[...]

  • Page 29

    25 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S Many functions of the scanner can be configu red or enabled/disa bled. The scanner is shipped from the factor y c onfigured to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages. If an asterisk is not in the default column, [...]

  • Page 30

    26 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB MSI-Plessy 10/10 Check Digit 9 9 9 9 MSI- Pless y Mod 10 Ch eck D igit * 9 9 9 9 Paraf Support ITF 9 9 9 9 ITF Symbol Lengths Variable 9 9 9 9 Symbol Length Lock None 9 9 9 9 Beeper tone Normal 9 9 9 9 Beep/transmit sequence Before transmit 9 9 9 9 Commun[...]

  • Page 31

    27 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB Transmit UPC-A Item ID# * 9 9 9 9 Transmit Codabar Start/Stop C haracters 9 9 9 9 CLSI Editing (Enabl e) 9 9 9 9 Transmit Mod 43 Check digit on Code 39 9 9 9 9 Transmit Mod 10/ITF 9 9 9 9 Transmit MSI-Plessy 9 9 9 9 Parity No 9 9 9 Baud Rate 9600 9 8 Data[...]

  • Page 32

    28 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB XON/XOFF Handshaking 9 ACK/NAK 9 Two Digit Supplements 9 9 9 9 Five Digit Supplements 9 9 9 9 Bookland 9 9 9 9 977 (2 digit) Supplemental Requirement 9 9 9 9 Supplements are not Required * 9 9 9 9 Two Digit Redundancy * 9 9 9 9 Five digit Redundancy 9 9 9[...]

  • Page 33

    29 C ONFIGURATION M ODES The MS1890 Series has three modes of confi guration. • Bar Codes The MS1890 can be configur ed by scanning the bar codes include d in the Metrologic Single-Line Co nfiguration Guide ( MLPN 00-02544) or the Area Imaging Bar Code Supplemental Co nfiguration Guide ( MLPN 00-02281). These manuals can be do wnloaded for FREE f[...]

  • Page 34

    30 U PGRADING THE F LASH ROM F IRMWARE The MetroSet2 program is a functional c omponent of Metrologic’s ne w line of Flash- based scanners. T his program allows the user of a Metrologic sca nner to quickly upgrade to a ne w or custom version of firmware. It requires the use of a personal computer runnin g Windows 95 or greater and the u se of a s[...]

  • Page 35

    31 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1890-14, RS232 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 Reserved 8 Reserved 9 +5VDC The MS1890 scanner interfaces terminate to a 10-pin, RJ45 Female Socket. The serial # label indic ates the interface enabled when the [...]

  • Page 36

    32 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1890-38, Low Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 USB D+ 7 V USB 8 USB D- 9 +5VDC 10 Shield Ground MS1890-40, Full Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Inpu[...]

  • Page 37

    33 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) RS232 PowerLink Cable MLPN 53-53700 x -3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Power/Signal Ground 6 Reserved 7 CTS Input 8 RTS Output 9 +5VDC 9-Pin D-Type Connector Stand-Alone Keyboard Po werLink Cable[...]

  • Page 38

    34 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge Po werLink Cable MLPN 53-53702x-3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 VDC 5-Pin DIN, Female Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 VDC 5 PC Clock 6 No Connect 6-Pin DIN, Male Metrologic will suppl[...]

  • Page 39

    35 L IMITED W ARRANTY The MS1890 series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A . facility and at its Su zhou, China facility . The MS 1890 series scanner s have a three (3) year limite d warranty from the date of manufac ture. Metrologic warrants and represents that all MS1890 series scanners are free of all def[...]

  • Page 40

    36 R EGULATORY C OMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 LED Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adj ustments or performan ce of procedures other than tho se specified herei n may result in h azardous radi ation exposur e. Under no circum stances sh ould the cust omer attempt [...]

  • Page 41

    37 R EGULATORY C OMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class A Devices The follo wing is applicabl e when the scann er cable is g reater in lengt[...]

  • Page 42

    38 R EGULATORY C OMPLIANCE EMC Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable w hen the scanner cable is les s than 3 meters (9.8 feet) in length w hen full y extended: Les instructions ci-de ssous s’ap[...]

  • Page 43

    39 P ATENTS For patent information, please refer to www.honeywellaidc.com/patents .[...]

  • Page 44

    40 I NDEX A AC ................................. 2, 7–11, 23 Accessori es ................................... 2 Adapter .................................... 2, 34 Apertu re......................................... 4 Audible Indica tor .............. 14–15, 30 B Bar Code ................... 18– 21, 22, 29 Bar Code Element .....................[...]

  • Page 45

    41 I NDEX Light Lev els ................................. 23 Light S ource ................................ 22 M Maintenanc e .................................. 6 Meteor ......................................... 30 MetroSelect ..................... 13, 24, 29 MetroSet 2 .................................... 30 Mode of Oper ation ....................[...]

  • Page 46

    42[...]

  • Page 47

    [...]

  • Page 48

    September 2007 Printed in the USA 00 - 02293 B[...]