Metra Electronics 99-8211 manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Metra Electronics 99-8211, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Metra Electronics 99-8211 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Metra Electronics 99-8211. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Metra Electronics 99-8211 should contain:
- informations concerning technical data of Metra Electronics 99-8211
- name of the manufacturer and a year of construction of the Metra Electronics 99-8211 item
- rules of operation, control and maintenance of the Metra Electronics 99-8211 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Metra Electronics 99-8211 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Metra Electronics 99-8211, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Metra Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Metra Electronics 99-8211.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Metra Electronics 99-8211 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION INSTRUCTIONS FOR P ART 99-8211 Small Flat Blade Screwdriver I Phillips Screwdriver I Socket Wrench 1-800-221-0932 www .metr aonline.com KIT FEA TURES © COPYRIGHT 2004 METRA ELECTRONICS CORPORA TION APPLICA TIONS 2000-04 T O Y O T A A V ALON • DIN Head Unit Provisions with Pocket • ISO DIN Head Unit Provisions with Pocket A) Radi[...]

  • Page 2

    99-8211 • Dash Disassembly - 2000-2004 T oyota A valon (column shift models) . . . . . . . . . . . 1 - 2000-2004 T oyota A valon (console shift models) . . . . . . . . . . 2 • Kit Assembly - DIN Head Unit Provision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - ISO DIN Head Unit Provision . . . . . . . . . . . . . . . . . . . .[...]

  • Page 3

    99-8211 1 DA SH DIS ASSEMBL Y 2000-2004 TO Y OT A A V ALON (column shift models) Disconnect the negative batter y terminal to prevent an accidental short circuit. Unsnap the trim below the climate control to reveal (2) 10 MM bolts and remove . (Figure A) 1 2 A Carefully pull air vents above radio towa rds rear of car to unsnap . Note: There are (3)[...]

  • Page 4

    2 99-8211 DA SH DIS ASSEMBL Y 2000-2004 TO Y OT A A V ALON (console shift models) Disconnect the negative batter y terminal to prevent an accidental short circuit. Open the center console armrest, unsnap cover above cup holder and r emove (2) Phillips screws to ward the outside of the panel. (Figure A) 1 2 A Carefully pull air vents above radio tow[...]

  • Page 5

    3 99-8211 KIT A SSEMBL Y DIN Head Unit Provision 1 Slide the mounting bracket onto the 99-8211 until side clips engage . (Figure A) 2 Slide factor y climate controls into the 99-8211 and secure using the factor y hardw are . (Figure B) 3 Slide the DIN cage into the Radio Housing and secure by bending the metal locking tabs down. (Figure C) 4 Slide [...]

  • Page 6

    4 99-8211 KIT A SSEMBL Y ISO DIN HEAD UNIT PRO VISION 1 Slide the mounting bracket onto the 99-8211 until side clips engage . (Figure A) 2 Slide factor y climate controls into the 99-8211 and secure using the factor y hardw are . (Figure B) 3 Mount the ISO Brackets to the head unit with the screws sup- plied with the unit. 4 Slide the head unit int[...]

  • Page 7

    5 99-8211 FINAL A SSEMBL Y A Locate the factor y wiring harness in the dash. Metra recommends using the proper mating adapter and making the connections as shown. (Isolate and individually tape off the ends of any unused wires to prevent electrical short circuit) Re-connect the negative batter y terminal and test the unit for proper operation. A) S[...]

  • Page 8

    6 NOTES 99-8211[...]

  • Page 9

    7 NOTES 99-8211[...]

  • Page 10

    1-800-221-0932 www .metr aonline.com © COPYRIGHT 2004 METRA ELECTRONICS CORPORA TION INST998211[...]