Master Lock LTR4-512 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Master Lock LTR4-512, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Master Lock LTR4-512 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Master Lock LTR4-512. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Master Lock LTR4-512 should contain:
- informations concerning technical data of Master Lock LTR4-512
- name of the manufacturer and a year of construction of the Master Lock LTR4-512 item
- rules of operation, control and maintenance of the Master Lock LTR4-512 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Master Lock LTR4-512 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Master Lock LTR4-512, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Master Lock service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Master Lock LTR4-512.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Master Lock LTR4-512 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    LTR4-512 LTR8-512 LTR8-512M Master Clock Installati on & User's Guide[...]

  • Page 2

    Lathem, the Lathem logo, LT R4-512, LTR8-512, LTR8-512M, Radio Sync, LTR MasterLink, Terminal Manager an d PayClock are registered trademarks of Lathem Time Corporation. Other prod uct names mentioned in th is manual may be trademarks of t heir respective companies and are hereby acknowledge d. WARNING: Changes or modifications to this product not [...]

  • Page 3

    Table of C ontents Welcome ....... ..... ...... ..... ...... ..... ..... ....... ...... ..... ...... ..... ..... ...... ..... ..... ........ ..... ....1 Step 1 - Mounting the Ma ster ......... ..... ..... ...... ..... ..... ...... ..... ....... ...... ..... ...... ..... ..... .2 S URFACE M OUNT ..... ...... ..... ...... ..... ..... ...... ..... ...[...]

  • Page 4

    LTRx-512 Insta llation and User’s Guide 1 Welcome Thank you for purchasing y our new MASTER CLOCK. You can use yo ur new Master to ring bells or turn on circuits for up to 9 9 seconds, as well as to synchroni ze the time on secondary wall clocks o r devices. This manual covers 3 models of MAS TER clocks: the LTR4-512 , the LTR 8-512 and the LT R8[...]

  • Page 5

    LTRx-512 Insta llation and User’s Guide 2 Step 1 - Mounting the Master The Master comes ready to surface mount on the wa ll. However, you can also insta ll the Master in a standard 19" rack, recess the power supply into the wa ll or hide the power supply in the floor or ceiling and hang only the display unit on the wall wit h optiona l hardw[...]

  • Page 6

    LTRx-512 Insta llation and User’s Guide 3 To surface mount the Ma ster 1. Place the Master on its ba ck with the display unit facing up and the keypad to the right 2. Remove the two s crews from just abo ve the display unit 3. Lift the display unit up and aw ay from yo u. Note that two rivets at t he bottom of the co ver prevent you from lifting [...]

  • Page 7

    LTRx-512 Insta llation and User’s Guide 4 Lowering the Dis play Unit during Testing With a Semi-Flush or Surfa ce mount, you can hang the dis play unit below the back box when testi ng the Master and its ci rcuits. To lower the display unit, remov e the two screws that attach the display unit to the back box. Lif t the unit up and away fro m the [...]

  • Page 8

    LTRx-512 Insta llation and User’s Guide 5 Rack Mount The LTR8-512 and LTR8-51 2M come wit h two L-shaped brackets (optional on the LTR4-512 ) so you can install your Mas ter in a standard 19 -inch rack To install the Master in a 19-inch rack 1. Place the Master on its ba ck with the display unit facing up and the keypad to the right 2. Remove the[...]

  • Page 9

    LTRx-512 Insta llation and User’s Guide 6 10. Remove the two screws fro m the side of the display unit 11. Using these same screws , attach an “L” bracket (or ear) 12. Repeat to attach the other ear 13. Mount the unit in the rack 14. Follow the wiring steps i n the next chapter before attaching the box cover 15. Attach the furnished cover to [...]

  • Page 10

    LTRx-512 Insta llation and User’s Guide 7 Attach the ground wire to o ne of the lower power supply mounting s crews Note: UL re gulations r equire that yo u do NOT place high v oltage (120V) and lo w volt age communication cables in the same co nduit or through the same knock out holes • Follow the wiring s teps in step 2 • For the cleanest i[...]

  • Page 11

    LTRx-512 Insta llation and User’s Guide 8 Step 2 – Wiring the Master Wire the display panel and power relay units fo r bell control and clock synchronization. Refer to the diagrams in Appendix C2 fo r more details. Until you complete this part of the wi ring, do not turn on the AC power to P4 , and keep the power/relay unit’s toggle switch tu[...]

  • Page 12

    LTRx-512 Insta llation and User’s Guide 9 Power Supply – LTR4 Your Master is a lready setup for 120 VAC operatio n. If you need to wire it f or 220/ 240VAC , change the jumper settings as sho wn in the drawings on page 8. TERMINAL BLOCK ‘P4’ WIRING THE LTR8-512 FOR 1 20VA C (nom.) OPERATION J1 insta lled between 3 & 4 and J2 installed b[...]

  • Page 13

    LTRx-512 Insta llation and User’s Guide 10 We recommend using stranded wire i nside the Power Supply Box. Stranded wire allows for a firm connection to the Quick Co nnect terminals. Stranded wires are a lso less likely to interfere with the relay board components. If yo u must use solid wire, joi n the stranded wire to the solid wire in a nother [...]

  • Page 14

    LTRx-512 Insta llation and User’s Guide 11 Step 3 – Setting Up the Master If you will use the Maste r to sync clocks, you must first use relays #7 & #8 (terminal block P1) for synching. If you have an LTR8 -512 or LTR8 -512M and will use a second clock type, you must use relays #5 & #6 (te rminal block P2) for those clocks Bell Zone #1 [...]

  • Page 15

    LTRx-512 Insta llation and User’s Guide 12 To set the date and time, select Functio n [1] by keying [#][1][#] Enter the numbers for the month, date and year (4-digit yea r), then pre ss [#], such as [0][4][0][3][2][0][ 0][3][#] shown below: Enter a number [1] - [ 7] for the day of the week, Sunday through Saturday: [1]=Sunday [2]=Monday [3 ]=Tues[...]

  • Page 16

    LTRx-512 Insta llation and User’s Guide 13 If you enter a time less tha n 13:00 (1:00 PM), then you will see SELECT [0] PM / [1] AM Press [0] for PM or [1] fo r AM. If you choose ‘PM’, then the time will display in 24 -hour format to confirm your entry Press the [#] key at the top (‘00’ seconds) o f the new minute to accept. If the ti me [...]

  • Page 17

    LTRx-512 Insta llation and User’s Guide 14 3D - Choose Clock Types If you will use the Master to synchronize electro-mechanical wall clocks (analog o r digital), then use Function [2] to choo se the clock type for Clock # 1 and/o r Clock #2, fo llowing the instructions below . Clock Control C odes can be found in Appendix C1. NOTE: You do not nee[...]

  • Page 18

    LTRx-512 Insta llation and User’s Guide 15 3E - Test Bell Circuits Manual Bell Control Use Manual Bell Control Function [3] (described on Pg . 20 to test s elected bell circuits . Press [#][3][#] to start thi s function Auto Test the Bells Use the Auto Bell Test feature to turn on all bell relays once per minute at the sta rt of each minute. Once[...]

  • Page 19

    LTRx-512 Insta llation and User’s Guide 16 3G – Setup Communication The “factory defa ult” communicatio n settings (LTR8-51 2 and LTR8-512 M only) are: Baud Rate: 9600 Terminal ID#: 065 Use Function [B] (described on Pg. 30) if yo u if yo u need to change these settings fo r MasterLink configuratio ns involving multiple Masters, You can set[...]

  • Page 20

    LTRx-512 Insta llation and User’s Guide 17 Additional Functions: All of the Master’s functions are described in the next section o f this guide. Remaining s teps, which may be performed “as needed” by the Installer or User, include the following: Function Number Progr amming Operation . 0 Enter Password 1 Set Date / Time 3 Manual Bell Contr[...]

  • Page 21

    LTRx-512 Insta llation and User’s Guide 18 Function Descriptio ns [#] Starts the Program ming Functions a nd Confirms Entries [*] Ends Program functions a nd/or Cancels Entries (except the “Quick Check”) Quick Check Commands Quick Check comma nds display system i nformatio n for about 2 seconds. You can press any o f the three “corner quick[...]

  • Page 22

    LTRx-512 Insta llation and User’s Guide 19 [0] = Password You must enter a passw ord for mos t programming f unctions. To enter your passw ord, press [#][0][#] Enter your 6-digit passw ord, then press [#] Once you enter your password, you ca n now program y our Master until it detects that y ou haven’t pressed a key for 5 minutes. After that, y[...]

  • Page 23

    LTRx-512 Insta llation and User’s Guide 20 Once you press [#], enter the time of the next u pcoming minute , using either 12 -hour or 24-hour format, then press [#]. (If using 24 -hour format, enter midnight as 00:00) For e xample, if the curr ent time is 08 :59, enter : 09:00 If you enter a time less tha n 13:00 (1:00 PM), then you will see SELE[...]

  • Page 24

    LTRx-512 Insta llation and User’s Guide 21 [2]=Select Clock Control This function requires the adminis trator pass word Use this functio n to choose the ma ke/model of the clock s that your Mas ter will synchronize (Note: The LTR4-512 can only synchronize one type o f secondary s ystem) Enter your administrato r password, then start this function[...]

  • Page 25

    LTRx-512 Insta llation and User’s Guide 22 Press [0] to turn them all off, or press keys [1] - [8] to turn a circuit off or on When you see the circuits that yo u want to ring, press and hold the [#] key. The front panel lights will light up to show tha t you have turned on those relays . Release the [#] key to turn those relays back off. Note th[...]

  • Page 26

    LTRx-512 Insta llation and User’s Guide 23 The follow ing will show o n the display: For Firmw are version 4.05 and earlier: For Firmw are version 4.06 and later: To select the appropriate mode: Press [1] DATA ENTRY to create a new schedule Press [2] DATA SCAN to view a schedule Press [3] DATA EDIT to change a s chedule Press [4] CLEAR to clear a[...]

  • Page 27

    LTRx-512 Insta llation and User’s Guide 24 Then select the days when this event occurs [0] selects no days, [1]-[7] selects Sunday-Saturday, [8] selects holidays and [9] selects all days (including holidays). Press these keys to turn days on or off . After you choose the days when the event will occur, press [#] Example: Press 1,3,5,7,8 to turn o[...]

  • Page 28

    LTRx-512 Insta llation and User’s Guide 25 [5]=Schedule Changes (Use the handy program ming charts included at the end of t his Guide) If you wish to activa te schedules at a future date, use Schedule Changes to prog ram a schedule’s start date and time. This functio n works much like the Bell Schedule Function [4]. Enter your password (#0#), t[...]

  • Page 29

    LTRx-512 Insta llation and User’s Guide 26 [6]=Enable or Disable Circuits This function requires the adminis trator pass word. Use this functio n to Enable and Disable your Mast er’s control relays during circuit wiring or maintenance. This function can a lso ‘hold back’ clocks to manually adjust for daylight s avings i n the fall if you ha[...]

  • Page 30

    LTRx-512 Insta llation and User’s Guide 27 [9]=Sync Clocks Use this functio n to quickly sync any secondary clo cks that los e time. This can occur if po wer to your LTRx-512 st ayed on while power to the seco ndary clocks sto pped. Note: This function is primarily us ed during initial installatio n of the secondar y system , if there has been ma[...]

  • Page 31

    LTRx-512 Insta llation and User’s Guide 28 [A]=Program Holidays You can enter up to 16 dates a s holidays i n your LTRx-512 . During holidays, only the events that yo u set to occur on holida ys will turn on when they reach the scheduled time. Examples : 1) Select S mtwtf SH for a n event to o ccur on S unday, S aturday, or any day se tup as a H [...]

  • Page 32

    LTRx-512 Insta llation and User’s Guide 29 [B]=Communications (LT R8-512 and LT R8-512M Only) This function requires the adminis trator pass word Use this functio n if you use LTR Mast erLink or Terminal Manag er software wi th your LTR8-512 You cannot choose f unction [B] directly. To enter Communicatio ns, press [#][9][0][0][#] Use this functio[...]

  • Page 33

    LTRx-512 Insta llation and User’s Guide Daylight Sav ings Codes 30 APPENDIX A - SPECIF ICATIONS ELECTRICAL: Input Voltage 120 or 220 / 240 VAC @ 60 Hz or 50Hz Input Power 50 VA ma x (less than 0.5A @ 1 20V) Memory / Quartz Time Ba ckup 10 year (nom.) Lithium Battery Bell / Clock Control Relays 120VA C / 28V DC, 10A , Plugga ble Fuse 1 x 1.0 A mp [...]

  • Page 34

    LTRx-512 Insta llation and User’s Guide Daylight Sav ings Codes 31 APP ENDIX B – DAYLIGHT SAV INGS COUNTRY CODE S ALBANIA 02 ENGLAND 01 MALTA 02 ANDORRA 02 ESTONIA 02 MONACO 02 ARMENIA 02 FALKLAND ISLAND S 10 NETHERLANDS 02 AUSTRIA 02 FINLAND 02 NEW ZEALAND 11 AZERBJAN 02 FRANCE 02 NORWAY 02 AZORES 02 GERMANY 02 POLAND 02 BAHAMAS 08 GIBRALTER 0[...]

  • Page 35

    LTRx-512 Insta llation and User’s Guide Secondary Clock Types 32 APPENDIX C1 - SECO NDARY CLOCK TYPE CODES Type Description Page 01 SYNCHRONOUS WIRED 33 01 LATHEM TYPE SS 33 01 CINCINNATI D10 33 01 IBM 77 SERIES 33 01 SIMPLEX 77 SER 33 01 SIMPLEX 93-9 3 3 01 SIMPLEX 91-9 3 3 01 SIMPLEX 941-9 33 01 SIMPLEX 943-9 33 01 SIMPLEX 6310-9 231 33 01 STAN[...]

  • Page 36

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 33 APPENDIX C2 - WIRING SECONDA RY CLOCKS TYPE 01 - SYNCHRONOUS WIRED TYPES INCLUDE: Lathem Type SS Wall Clocks Cincinnati D1 0 (115VA C), D12 (24VAC ) IBM 77 Series Simplex 7 7 Series, 93-9, 9 1-9, 941-9, 9 43-9, 631 0-92 31 Stromberg 3000 All circuits should be fused or protected by a cir[...]

  • Page 37

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 34 TYPE 02 - THREE WIRE MINUTE IMPULSE (59 TH MIN.) TYPES INCLUDE: Lathem Type ISC (3-Wire) Cincinnati D2 , D4 Edwards Impulse Faraday Impulse IBM 75 Series Simplex 7 4 Series, 91-4, 9 3-4, 941-4, 9 43-4, 631 0-90 75, 631 0-9231 Standard Impulse Stromberg Impulse All circuits should be fuse[...]

  • Page 38

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 35 TYPE 02 - TWO WIRE REVERSE POLARITY MINUTE IMPULSE (59 TH MIN.) TYPES INCLUDE: Lathem Type ISC (2-Wire) Cincinnati D3 Using PS8-24 12 Power Supply: Using PS8-24 Power Supply: * Green and Black Wires in Clock Cable are unused. All circuits should be fused or protected by a circuit breaker[...]

  • Page 39

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 36 TYPE 03 - STANDARD ELECTRIC SYNCHRONOUS (*Old Style: Dual Motor) AMERICAN TIME & SIGNAL #X5 5BHGA801 All circuits should be fused or protected by a circuit breaker (10Amp maximum) Note: For New Style (Moto r+Solenoid), see Type 06 (Fa raday)[...]

  • Page 40

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 37 TYPE 04 - STANDARD ELECTRIC TIME AR-2A TWO WIRE DUAL V OLTAGE All circuits should be fused or protected by a circuit breaker (10Amp maximum) TYPE 05 - THREE WIRE MINUTE IMPULSE (58 TH MIN.) All circuits should be fused or protected by a circuit breaker (10Amp maximum)[...]

  • Page 41

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 38 TYPE 06 - SYNCHRONOUS WIRED TYPES INCLUDE: Cincinnati D8 Faraday ( New Style: Motor + So lenoid) Honeywell ST402A All circuits should be fused or protected by a circuit breaker (10Amp maximum) TYPE 07 - DUKANE 24F 200 DIGITAL C LOCKS All circuits should be fused or protected by a circuit[...]

  • Page 42

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 39 115VAC TYPE All circuits should be fused or protected by a circuit breaker (10Amp maximum) 24VAC TYPE All circuits should be fused or protected by a circuit breaker (10Amp maximum) TYPE 09 - SIMPLEX 59 TH MINUTE DUAL MOTOR TYPE 10 - SIMPLEX 45 TH MINUTE DUAL MOTOR TYPE 27 - SIMPLEX 2310 [...]

  • Page 43

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 40 TYPE 11 - EDWARDS DUAL MOTOR All circuits should be fused or protected by a circuit breaker (10Amp maximum) TYPE 12 - CINCINNATI ‘D6’ CLOC KS All circuits should be fused or protected by a circuit breaker (10Amp maximum)[...]

  • Page 44

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 41 Type 14 - ELECTRONIC CODED CLOCKS Clocks run normally with 12 0 VAC po wer. For any bells or clock correctio n, the generator prestart relay (SK1) first turns on fo r the signal-generator to reach fr equency. SK1 turns on at the 00 seco nd after a progra mmed time or manual bell time. Th[...]

  • Page 45

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 42 Clock correction a nd bell circuit operations are generated by sequentially applying va rious frequencies onto the 120 VAC . Each bell and clock correction circuit has its own frequency. Each bell and clock correction circuit has a receiver circuit t hat applies the ass ociated bell or c[...]

  • Page 46

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 43 TYPE 16 - THREE WIRE MINUTE IMPULSE (59 MIN) WITH 12-HOUR CORRECTION TYPES INCLUDE: Simplex 91 and 94 1 SAME WIRING AS FOR TYPE 02 (3-WIRE) TYPE 16 - TWO WIRE REVERSE POLARITY MINUTE IMPULSE (59 MIN) WITH 12-HOUR CORRECTION SAME WIRING AS FOR TYPE 02 (2-WIRE) ____________________________[...]

  • Page 47

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 44 TYPE 18 - NATIONAL SYNCHRONOUS W IRED TYPES INCLUDE: Dukane 24 0 Series Rauland 2463 Series All circuits should be fused or protected by a circuit breaker (10Amp maximum) TYPE 19 - STROMBERG SYNCHRONOUS WIRED TYPES INCLUDE: Stromberg Synchronous Lathem Type SS Wall Clocks (modif ied) NOT[...]

  • Page 48

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 45 TYPE 20 - THREE WIRE MINUTE IMPULSE (44 TH MIN.) All circuits should be fused or protected by a circuit breaker (10Amp maximum) TYPE 21 - CINCINNATI ‘D1’ All circuits should be fused or protected by a circuit breaker (10Amp maximum)[...]

  • Page 49

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 46 TYPE 22 - DUKANE SYNCHRONOUS W IRED All circuits should be fused or protected by a circuit breaker (10Amp maximum) TYPE 23 - CONDOR DIGITAL CLOC KS (Model 2412 ) TYPES INCLUDE: Condor 2 412 If the digital clocks lose sync with the LTRx-512 , then you can use function [9]=SYNC CLOCKS to r[...]

  • Page 50

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 47 TYPE 23 - RAULAND DIGITAL CLOC KS (Model 2422 ) TYPES INCLUDE: R auland 2422 If the digital clocks lose sync with the LTRx-512 , then you can use function [9]=SYNC CLOCKS to re-sync them. All circuits should be fused or protected by a circuit breaker (10Amp maximum) All circuits should b[...]

  • Page 51

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 48 TYPE 23 - CONDOR DIGITAL CLOC KS (BAR-AC-4412) If the digital clocks lose sync with the LTRx-512 , then you can use function [9]=SYNC CLOCKS to re-sync them. All circuits should be fused or protected by a circuit breaker (10Amp maximum)[...]

  • Page 52

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 49 TYPE 24 - EDWARDS SYNCHRONOUS WIRED CL OCKS - TYPE E1 All circuits should be fused or protected by a circuit breaker (10Amp maximum)[...]

  • Page 53

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 50 APPENDIX D - WIRING DIAGRA MS: POWER, BELLS, ETC. Fig. D1 - TERMINAL BLOCK ‘P4’ WIRING THE LTRx-512 FOR 1 20VAC (nom.) OPERATION All circuits should be fused or protected by a circuit breaker (10Amp maximum) WIRING THE LTRx-512 FOR 220/240 VAC (nom.) OPERATION All circuits should be [...]

  • Page 54

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 51 Fig. D2 - TYPICAL SIGNAL DEVICE WIRING All circuits should be fused or protected by a circuit breaker (10Amp maximum)[...]

  • Page 55

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 52 Fig. D3 - COM PUTER CABLE (For Front Access Port) (LTR8-512 and L TR8-512M Only) Fig. D4 - RS-232 CABLE (for permanent connection to the Communicati ons Terminal Block) (LTR8-512 and L TR8-512M Only)[...]

  • Page 56

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 53 Fig. D5 - SYNCHING UP TO 6 0 RS-485 TIM E SYNC DEVICES WITHOUT A BUFF ER - 1 2 3 4 5 10 1 1 12 13 6 7 8 9 TxD Rx D D + D G N D G N D S Y N C D + D - D + D - ~ ~ ~ RS-232 RS-485 SYNC OUT SYNC IN 12V~ AC OUT 250ma MODEM HOST COMMUNICA T IONS L TR8 -512 & LTR8-512M Only PULSE SYNC RS-48[...]

  • Page 57

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 54 Fig. D7 – COM MUNICATION TERMINAL BLOCK Rear of Display U nit NOTES: 1. Twisted-pair (Cat-3/ Cat-5) wire connects di rectly to Terminal Block; up to 2 w ires per positio n 2. Pulse-sync input is same as provided in power supply. One (1) second (min.) dry-contact switch clos ure across [...]

  • Page 58

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 55 RS-485 Sync Time Device C onnection • Sync In: Terminal block pair used to receive RS-485 synchronizatio n from another Lathem Ma ster product or radio sy nc device, or transmit the LTRx-512 ’s own sync co mmands to up to 31 RS-485 devices, including Lathem Masters a nd DDC4R Wall Cl[...]

  • Page 59

    LTRx-512 Insta llation and User’s Guide Wiring Dia grams 56 Fig. D8 - POWER SUPPLY TERMINAL BLOCK S NOTES: 1. Circuits CK T1...CKT4 designate bell controls. Circuit pairs CKT5 /CKT6 a nd CKT7/CKT8 can function as clock synchronizatio n circuits or as bell controls ( Note: CKT1…C KT4 do not e xist on the LTR4 -512. Instea d use CKT5… CKT8 whic[...]

  • Page 60

    LTRx-512 Insta llation and User’s Guide Installing the Modem 57 APPENDIX E – INSTALL THE OPT IONAL MODEM Installation of the optional internal modem sho uld be performed by a trained and competent electronics technician. Follow these steps; 1. Turn off the power to the Ma ster Clock. You can either access the on/off s witch inside the Power Sup[...]

  • Page 61

    LTRx-512 Insta llation and User’s Guide Connecting the LTR-GPS Satellite Receiver/Synchronizer 58 APPENDIX F – Connecting the LTR-GPS Satellite Recei ver / Synchronizer Lathem’s LTR-GPS is a Global Pos itioning Satellite receiver us ing 12 -channels to access the accurate d ate and time signa l transmitted each second by 24 satellites i n geo[...]

  • Page 62

    LTRx-512 Insta llation and User’s Guide Power Supply Schematics 59 APPENDIX G – POWER SUPPLY SCH EMATICS LTR8-51 2 / LTR8-512 M LTR4-512 C3 C4 C5 D1 1 D10 D9 D12 K1 K2 K3 K4 K6 K7 K8 K5 VMM7086 REV . D (C) 20 00 LA T HEM TIME CORP . D3 D4 D5 D 6 C3 C4 C5 D1 1 D10 D9 D12 K6 K7 K8 K5 (C) 2000 LA THEM TIME CORP . VMM7086 REV . D D3 D4 D5 D6[...]

  • Page 63

    LTRx-512 Installatio n and User’s Guide Programming C harts 60 BELL SCHEDULE PROGRAM MING CHART SCHEDULE #: 1 2 3 4 5 6 7 8 (Circle One) DATE:___ _-____ -____ REC No. DAYS SMSTWTFSH CIRCUITS 12345678 START HH:MM DUR SS REC No. DAYS SMSTWTFSH CIRCUITS 12345678 START HH:MM DUR SS Ex. MTWTF 1 234 08:00 5 Ex. MTWTF 1234 08:00 5 01 33 02 34 03 35 04 3[...]

  • Page 64

    LTRx-512 Installatio n and User’s Guide Programming C harts 61 SCHEDULE CHANGE DATES PR OGRAMMING CH ART DATE:____-__ __-___ _ REC DATE TIME SC HEDULES NO. MM DD YY HH MM 123 45678 C OMMENTS Ex. 06 02 10 07 00 2345 Shortened Schedule 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 COPY THIS PAGE TO USE IN CREATING YOUR SCHEDULE CHANGE TABLE[...]

  • Page 65

    LTRx-512 Installatio n and User’s Guide Programming C harts 62 HOLIDAYS SETUP CHAR T DATE:____-__ __-___ _ RECORD DATE NO. MM DD YY C OMMENTS Ex. 07 04 1 0 Independe nce Day 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 COPY THIS PAGE TO USE IN CREATING YOUR HOLIDAY TABLE[...]

  • Page 66

    LTRx-512 I nstallation and User’s Guide 63 FOR UNIT S EQUIPPED WITH AN INTERNAL MODEM NOTICE: This equipme nt complie s with Pa rt 68 of the FCC Rule s . On th e mount ing panel of this equipment is a l abel that contains, among ot her inf ormation, the FCC Reg istration Numbe r and Rin ger Equivalen ce Number (REN) f or t his e quipment . If req[...]

  • Page 67

    LTRx-512 I nstallation and User’s Guide 64 Limited One-Year Limite d Warranty Lathem warrants the hardwa re products described in this gui de against defects in material and workm anship for a period o f one year from date o f origina l purchase from Lathem or from an authorized Lathem reseller. The conditions of this warranty a nd the extent of [...]

  • Page 68

    LTRx-512 I nstallation and User’s Guide 65 Index A Administrato r password .. ...... ..... ..... ...... .. 1 1, 19 Auto Bell Test ......... ..... ..... ...... ..... ..... ... 15, 22 B Baud rate .......... ..... ...... ..... ...... ..... ....... ... 2 9 Baud Rate ......... ...... ..... ...... ..... ..... ........ ... 1 8 Bell schedules ..... .....[...]