Maretron TLM150 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Maretron TLM150, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Maretron TLM150 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Maretron TLM150. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Maretron TLM150 should contain:
- informations concerning technical data of Maretron TLM150
- name of the manufacturer and a year of construction of the Maretron TLM150 item
- rules of operation, control and maintenance of the Maretron TLM150 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Maretron TLM150 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Maretron TLM150, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Maretron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Maretron TLM150.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Maretron TLM150 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Revision 1.2 Page i ® ® TLM150 Gasoline Tank Level Monitor User’s Manual Revision 1.2 Copyright © 2010 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021 http://www.maretron.com Maretron Manual Part #: M002301[...]

  • Page 2

    TLM150 User’s Manual Page ii Revision 1.2 Revision History Revision Description 1.0 Original document 1.1 Corrected typo in NMEA 2000 protocol PGN list Corrected maximum depth in specification table 1.2 Added documentation on mounting locations and theory of operation Corrected torque specifications Added prohibition of red Loctite thr eadlocking[...]

  • Page 3

    Revision 1.2 Page iii ® ® Table of Contents 1  General .............................................................................................................................. .. 1  1.1  Introduction .................................................................................................................... 1  1.2  Ga[...]

  • Page 4

    TLM150 User’s Manual Page iv Revision 1.2 Table of Figures Figure 1 – TLM150 Mounting – SAE 5-Hole Bolt Pattern .......................................................... 5  Figure 2 – Mounting TLM150 to SAE 5-Hole Tank with Focus Tube ......................................... 6  Figure 3 – TLM150 Mounting With Threaded Adapter ....[...]

  • Page 5

    Revision 1.2 Page 1 ® ® 1 General 1.1 Introduction Congratulations on your purchase of the Mare tron Tank Level Monitor (TLM150). Maretron has designed and built your monitor to the highest standards for year s of reliable, dependable, and accurate service. The TLM150 is used to sense leve ls of gasoline tanks using ultrasonic technology and tran[...]

  • Page 6

    TLM150 User’s Manual Page 2 Revision 1.2 1.5 TLM150 Accessories Maretron offers the following accessories for the TLM150: • TA-5H-1.5NPT 1.5” NPT Dis placement Hull Tank Adapter • TA-5H-1.25BSP 1.25” BSP Displ acement Hull Tank Adapter • TFT-5H SAE 5-Bolt Pattern N on-Displacement Hull Focus Tube • TFT-1.5NPT 1.5” NPT Non-Displaceme[...]

  • Page 7

    ® ® TLM150 sensor component is 6°. Please refer to Figure 1 below for a diagram of the waves emitted and received by the TLM150. Please note that due to limitations of ultrasonic technology, the minimu m depth that can be measured by the TLM150 is 2” (5.08cm). Figure 1 - TLM150 Operation 2.3 Choosing a Mounting Location The primary function of[...]

  • Page 8

    TLM150 User’s Manual Page 4 Revision 1.2 • The sensor component of the TLM150 mu st be mounted over the deepest part of the tank, in order to obtain accurate dept h readings when the tank is empty or near empty. • In order to obtain accurate readings wh en the tank is empty, the tank bottom directly under the TLM150 mu st be both smooth and f[...]

  • Page 9

    ® ® WARNING • Gasket installs only one way and must be properly aligned to the tank and sensor for proper operation • Use only supplied gasket – other gaskets may obstruct and render device inoperative – do not use silicone sealant around the gasket • Use only Maretron adapters – others may have wrong diameter, rendering device inoper[...]

  • Page 10

    TLM150 User’s Manual 2.4.1.2 Installation on a Tank with a SA E J1810 5-Bolt Fitting and Focus Tube If a focus tube is used for a tank with a SAE J1810 5-bolt fitting, determine the depth of the tank at the location of the t ank sensor mounting hole and use a saw with a metal-cutting blade to trim the focus tube so that it reaches 1” above the [...]

  • Page 11

    ® ® 2.4.1.3 Installation on a Tank with a 1.25”BS P or 1.5”NPT Threaded Tank Fitting For a threaded tank sender mounting hole, firs t thread the adapter into the tank opening and tighten to a torque of 3-5 ft-lbs (4.1-6.8 N·m). Next, place the TLM150 gasket over the adapter so that the bolt holes on the gasket line up with the bolt holes on [...]

  • Page 12

    TLM150 User’s Manual 2.4.1.4 Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting and Focus Tube If a focus tube is used for a tank with a SAE J1810 5-bolt fitting, determine the depth of the tank at the location of the t ank sensor mounting hole and use a saw with a metal-cutting blade to trim the focus tube so that it rea[...]

  • Page 13

    ® ® 2.4.2 Mounting the TLM150 Interface Component The actual mounting of the TLM150 interface component is not critical and the unit can be mounted in any orientati on. The TLM150, NMEA 2000 ® connector, and cable are all waterproof (rated IP67 – prot ected against temporary immersi on in water) so you can mount the unit virtually anywhere. On[...]

  • Page 14

    TLM150 User’s Manual Figure 7 – NMEA 2000 ® Connector Face Views 3 Configuring the TLM150 The TLM150 has several configurable paramete rs, which are shown below including the default values. If you are not using the defaul t values, then you will need to refer to the corresponding section for confi guring the TLM150 appropriately. 1. Tank Numb[...]

  • Page 15

    Revision 1.2 Page 11 ® ® 3.2 Configuring Tank Capacity In addition to indicating the gasoline level within a tank, the TLM150 also has the abilit y to be configured or programmed wit h the attached tank’s capacity. This way, you will be able to view the tank’s capacity as well as the amount of gasol ine remaining anywher e on the vessel where[...]

  • Page 16

    TLM150 User’s Manual Page 12 Revision 1.2 5 Troubleshooting If you notice unexpected operation of the Mare tron TLM150, follow the troubleshooting procedures in this section to remedy simple problems. Symptom Troubleshooting Procedure No tank level output 1. If operating in the NMEA 2000 ® Mode , check the connection to the NMEA 2000 ® interfac[...]

  • Page 17

    Revision 1.2 Page 13 ® ® Symptom Troubleshooting Procedure Erratic Readings 1. Remove the sender and place it on top of a standard paper towel roll core. Be sure the towel core is on a hard surface. Reset the unit to factory defaults using either a DSM250 display or N2KAnalyzer. Power the unit up and wait for tw o minutes. The tank level value sh[...]

  • Page 18

    TLM150 User’s Manual Page 14 Revision 1.2 6 Technical Specifications Specifications Parameter Value Comment Accuracy ±2% Resolution ± 1% Number of Tank Types 1 Fuel (Gasoline only) Number of Tanks per Tank Type 16 16 Tanks per Tank Type Numbe red 0-15 Maximum Tank Depth 24” (0.61m) Minimum Depth Reading 2” (5.08cm) Sensor Deadband Support f[...]

  • Page 19

    Revision 1.2 Page 15 ® ® Mechanical Parameter Value Comment Size 3.9”” x 1.2” x 1.0” (99mm x 30.5mm x 25.4mm) Interface Component 2.7” dia. X 0.9” (68.6mm dia. x 22.9mm) Sensor Component 8.5” (215.9mm) Interconnecting Cable Weight 12 oz. (340g) Mounting SAE J1810 5-hole bolt pattern Can mount to 1.25” BSP or 1.5” NPT using avail[...]

  • Page 20

    TLM150 User’s Manual Page 16 Revision 1.2 8 Maretron (2 Year) Limited Warranty Maretron warrants the TLM150 to b e free from defects in materials and workmanship for t wo (2) years from the date of original purchase. If within the applicable per iod any such products sh all be proved to Maretron’s satisfaction to fail to meet the above lim ited[...]

  • Page 21

    Revision 1.2 Appendix A – NMEA 2000 ® Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing TLM150 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 127505 – Fluid Level The TLM150 uses this PGN to indicate the attached tank’s fluid instance, fluid type, fluid level, and tank capacity. Field 1: Fluid Instance – This field is us e[...]