Manley 500 / 200 WATT MONOBLOCK AMPLIFIER manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Manley 500 / 200 WATT MONOBLOCK AMPLIFIER, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Manley 500 / 200 WATT MONOBLOCK AMPLIFIER one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Manley 500 / 200 WATT MONOBLOCK AMPLIFIER. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Manley 500 / 200 WATT MONOBLOCK AMPLIFIER should contain:
- informations concerning technical data of Manley 500 / 200 WATT MONOBLOCK AMPLIFIER
- name of the manufacturer and a year of construction of the Manley 500 / 200 WATT MONOBLOCK AMPLIFIER item
- rules of operation, control and maintenance of the Manley 500 / 200 WATT MONOBLOCK AMPLIFIER item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Manley 500 / 200 WATT MONOBLOCK AMPLIFIER alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Manley 500 / 200 WATT MONOBLOCK AMPLIFIER, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Manley service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Manley 500 / 200 WATT MONOBLOCK AMPLIFIER.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Manley 500 / 200 WATT MONOBLOCK AMPLIFIER item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MANLEY LABORATORIES, INC. OWNER'S MANUAL MANLEY REFERENCE 500 / 200 W ATT MONOBLOCK MANLEY LABORATORIES, INC. 13880 MAGNOLIA AVE. CHINO, CA. 91710 USA TEL: (909) 627-4256 FAX: (909) 628-2482 email: emanley@netcom.com[...]

  • Page 2

    CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTING YOUR AMPLIFIER 5 DIAGRAM TOP VIEW 6 DIAGRAM REAR VIEW 7 DIAGRAM FRONT VIEW 8 BIAS PROCEDURES 9 OPERATIONAL NOTES 10 SPECIFICATIONS 11 WARRANTY 12 WARRANTY REGISTRATION 13 SECTION PAGE[...]

  • Page 3

    INTRODUCTION THANK YOU!... for choosing the Manley 500/200 Monoblock Amplifiers. Designed by David Manley, the Manley 500/ 200 Monoblock Amplifiers use only the best available components, with the shortest and cleanest signal path possible, and with the use of our own in-house CNC machine shop we can provide you with a amplifier that looks as good [...]

  • Page 4

    MAINS CONNECTIONS ! W ARNING! TO PREVENT THE RISK OF ELECTRIC SHOCK DO NOT OPEN THE CABINET REFER SERVICING TO QUALIFIED PERSONEL GENERAL NOTES LOCATION & VENTILATION The Manley 440/200 Monoblock Amplifiers must be installed in a stable location with ample ventilation. Allow a minimum of 2 inches of clearance on the top and sides of the amplifi[...]

  • Page 5

    CONNECTING YOUR AMPLIFIER Setting up your amplifiers is rather easy. 1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your preamplifier. 2. If using an UNBALANCED output from your preamplifier, connect the RCA interconnects from the output of the preamplifier or switching center to the RCA input on the back of the amplifie[...]

  • Page 6

    Amplifier Overhead View Tube Location OUTPUT TUBES:10 x RUSSIAN 6550 The 6550's used are the Russian Svetlana 6550's. This has been proven to be the rugged and reliable of this type and we strongly emphasize that only the RUSSIAN 6550's should be used in this amplifier. The MANLEY 440/200 WATT MONOBLOCK has been thoroughly optimised [...]

  • Page 7

    SPEAKER OUTPUT BINDING POSTS XLR BALANCED INPUT UNBALANCED BALANCED UNBALANCED BALANCED SELECT RCA UNBALANCED INPUT B+ FUSE SLO-BLO MAINS FUSE SLO-BLO MAINS IN IEC REAR VIEW[...]

  • Page 8

    FRONT VIEW OF AMPLIFIER WITH BIAS COVER PLATE REMOVED SHOWING BIAS ADJUST POTS READ BIAS FEEDBAC K SLOP E MINIMU M STANDAR D MAXIMU M MAINS POWER ON / OFF SWITCH OPERATE STANDBY EVER-WARM SOFT START SWITCH TRIODE TETRODE SWITCH POWER LED STANDBY LED (BLINKING) TRIODE TETRODE MANLEY DESIGNERS' REFERENCE SERIES 500 / 200 WATT MONOBLOCK DESIGNED [...]

  • Page 9

    BIAS PROCEDURES The Manley 500/200 Monoblock Amplifiers uses a fixed bias system that requires very little attention. We recommend checking the bias every 2-3 months or any time you replace an output tube. To adjust or check the bias, follow the following steps. For this procedure you will need a voltmeter (a hand held autoranging DMM digital multi[...]

  • Page 10

    OPERATIONAL NOTES SWITCHING ON -- SOFT START The MANLEY 500/200 is equipped with a SOFT-START circuit which lessens the initial stress the amplifier takes upon turn-on. We recommend that you use this soft start facility whenever you turn the amplifier on and especially when cold. 1. Ensure that the "mains" switch on the front panel is in [...]

  • Page 11

    SPECIFICA TIONS Vacuum Tubes: 10 x 6550 (Output), 2 x 6414 (Drivers), 1 x 12AT7 (Input) Output Power TETRODE: 500Watts (@1.5% THD 5 ohm load) TRIODE: 250 Watts (@1.5% THD 5 ohm load) Frequency Response, +/- .5 dB 10 Hz - 80 KHz Input Sensitivity 1V Input Impedance 100 KOhm Load Impedance 5 Ohm (fixed) S/N Ratio @440W -80 dB Power Consumption 30 Wat[...]

  • Page 12

    W ARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year warranty is available to the original purchaser upon proper registration of ownership within 30 days of date of firs[...]

  • Page 13

    WARRANTY REGISTRATION We ask that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 Registration entitles you to product support, full warranty benefits, and notice of product enhancements and upgrades. You MUST complete and return the following to[...]