Manley 50/50 manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Manley 50/50, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Manley 50/50 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Manley 50/50. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Manley 50/50 should contain:
- informations concerning technical data of Manley 50/50
- name of the manufacturer and a year of construction of the Manley 50/50 item
- rules of operation, control and maintenance of the Manley 50/50 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Manley 50/50 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Manley 50/50, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Manley service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Manley 50/50.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Manley 50/50 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MANLEY LABORATORIES, INC. MANLEY LABORATORIES, INC. 13880 MAGNOLIA AVE. CHINO, CA. 91710 TEL: (909) 627-4256 FAX: (909) 628-2482 OWNER'S MANUAL MANLEY REFERENCE DIRECT INPUT 50/50 STEREO AMPLIFIER[...]

  • Page 2

    CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTING YOUR AMPLIFIER 5 DIAGRAM TOP OVERHEAD VIEW 6 DIAGRAM REAR VIEW 7 DIAGRAM FRONT VIEW 8 BIAS PROCEDURES 9 OPERATIONAL NOTES 10 SPECIFICATIONS 11 WARRANTY 12 WARRANTY REGISTRATION 13 SECTION PAGE[...]

  • Page 3

    INTRODUCTION ! THANK YOU!... for choosing the Manley DIRECT INPUT 50/50 Amplifier. Designed by David Manley, the Manley DIRECT INPUT 50/50 Amplifier uses only the best available components, with the shortest and cleanest signal path possible, and with the use of our own in-house CNC machine shop we can provide you with a amplifier that looks as goo[...]

  • Page 4

    MAINS CONNECTIONS Your amplifier has been factory set to the correct mains voltage for your country. The voltage setting is marked on the serial badge, located on the rear panel. Check that this complies with your local supply. Export units for certain markets have a moulded mains plug fitted to comply with local requirements. If your unit does not[...]

  • Page 5

    CONNECTING YOUR AMPLIFIER Setting up your amplifier is rather easy. 1. Connect all LINE LEVEL source components (CD, Tuner, Tape, DAT, etc.) to the designated RIGHT & LEFT inputs on the back of the amplifier. 2. Connect the hot or "+" speaker cable to the red binding post and the common or "-" speaker cable to the black bind[...]

  • Page 6

    INPUT RCA OUTPUT B+ MAINS FUSES IEC MAINS IN Amplifier Overhead View with top cover removed OUTPUT TUBES:4 x RUSSIAN 6CA7/EL34 The 6CA7's used are the Russian up-rated 6CA7's. This has been proven to be the rugged and reliable of this type and we strongly emphasize that only the RUSSIAN 6CA7's should be used in this amplifier. The MA[...]

  • Page 7

    RCA INPUTS RCA INPUTS RECORD OUTPUTS SPEAKER OUTPUT BINDING POSTS MAINS FUSE SLO-BLO MAINS IEC AUX CD TAPE TUNER AUX CD TAPE TUNER RIGHT CHANNEL LEFT CHANNEL REAR VIEW OF AMPLIFIER[...]

  • Page 8

    FRONT VIEW OF AMPLIFIER SHOWING BIAS MEASUREMENT POINTS FRONT VIEW OF AMPLIFIER MANLEY AUX CD TAPE TUNER MANLEY DIRECT INPUT 50/50 STEREO AMPLIFIER READ BIAS VOLUME POWER SWITCH POWER LED GROUND 1 2 3 4 MUTE SWITCH MUTE LED[...]

  • Page 9

    BIAS PROCEDURES The Manley DIRECT INPUT 50/50 uses a fixed bias system that requires very little attention. If you wish to adjust or check the bias, follow the following steps. For this procedure you will need a voltmeter (a hand held autoranging DMM digital multimeter is the easiest) and a small flat screwdriver. 1. On page 8, which shows the FRON[...]

  • Page 10

    OPERATIONAL NOTES TUBE LIFE You should expect extended life from the tubes in your MANLEY DIRECT INPUT 50/50 if you adhere to the procedures described above and check your bias at least once every 2-3 months. We stock all the tubes in these amplifiers should you ever need replacements (and at very reasonable prices too!) FUSES The fuse used in your[...]

  • Page 11

    SPECIFICA TIONS Vacuum Tubes: 4 x EL34 (Output), 2 x 6414 (Drivers), 2 x 12AT7 (Inputs) Output Power 51 Watts (@1.5% THD 5 ohm load) Frequency Response, +/- .5 dB 10 Hz - 20 KHz at 50% rated power Input Sensitivity 375mV Input Impedance 100 KOhm Load Impedance 5 Ohm (fixed) S/N Ratio @50W -80 dB Power Consumption 220 Watts Quiescent 360 Watts Full [...]

  • Page 12

    W ARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year warranty is available to the original purchaser upon proper registration of ownership within 30 days of date of firs[...]

  • Page 13

    WARRANTY REGISTRATION We ask that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 Registration entitles you to product support, full warranty benefits, and notice of product enhancements and upgrades. You MUST complete and return the following to[...]