Linear RE-1 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Linear RE-1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Linear RE-1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Linear RE-1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Linear RE-1 should contain:
- informations concerning technical data of Linear RE-1
- name of the manufacturer and a year of construction of the Linear RE-1 item
- rules of operation, control and maintenance of the Linear RE-1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Linear RE-1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Linear RE-1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Linear service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Linear RE-1.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Linear RE-1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    RE-1 Residential T elephone Entr y System With Built-in Wireless Receiv er (760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com Installation, Progr amming, and Oper ation Instructions PRINTER’S INSTRUCTIONS: INSTR,INSTL,RE-1 - LINEAR P/N: 217490 C - INK: BLACK - MA TERIAL: 20 LB. MEAD[...]

  • Page 2

    CONTENTS FEA TURES • TWO-WA Y SPEAKERPHONE • CALL W AITING • CALL FORWARDING • DISTINCTIVE RINGS FOR ACCESS CALLS • SEVEN ACCESS TIME ZONES • TIMED “DO NOT DISTURB” PRIV ACY FEA TURE • DIGIT ALL Y SYNTHESIZED HUMAN VOICE PROMPTS • RESIDENCE CONTROL OF RELA YS • PROGRAMMABLE RELA Y CONTROL PREFIXES • 100 ENTRY CODE CAP ACITY [...]

  • Page 3

    1 PRODUCT DESCRIPTION Linear’ s RE-1 T elephone Entry System is designed for residential or light commercial access control applications. The speakerphone, ke ypad, radio receiver , and optional video camera are housed in a rugged enclosure that can be mounted to a pedestal or bolted directly to a wall. The die-cast ke ypad keys ha ve bright, eas[...]

  • Page 4

    2 INST ALLA TION INFORMA TION Before beginning installation, please re view the entire instructions and become familiar with the system’ s operation, wiring, and programmab le options. System Location For pedestrian door or gate installations, mount the Entry System on a rigid wall near the controlled door . Av oid mounting the unit in a location[...]

  • Page 5

    3 12 RELA Y TERMINAL BLOCK For Rela y #1 and Relay #2 output connections to the access control devices . 13 RELA Y INDICA TORS Indicators for Rela y #1 and Relay #2 will light when the rela y is activated. 14 ANTENNA TERMINAL BLOCK For shield and center conductor connection of the coax cab le from the system’ s built-in r adio antenna. 15 LINE MO[...]

  • Page 6

    4 WIRING DIAGRAM GATE OPERATOR OPEN 16 VAC 20 VA TRANSFORMER TELCO OPEN #1 KEYPAD GND KEYPAD DAT 1 KEYPAD DAT 0 KEYPAD PWR TRAN S FORMER TRAN S FORMER BATTERY NEGATIVE BATTERY PO S ITIVE S EN S E #1 COMMON KEYPAD CLK KEYPAD DVAL OPEN #2 RELAY #1 RE-1 TELEPHONE ENTRY SYSTEM S EN S E #2 TYPICAL GATE INSTALLATION WIRING GROUND STAKE N.O. COM N.C. N.O.[...]

  • Page 7

    5 ENTRY SYSTEM MOUNTING Pedestal Mounting The RE-1 Entry System can be mounted on a standard pedestal. 1. Open the RE-1 case by removing the tw o security screws with the wrench provided (see Figure 2). 2. Use four security bolts and locking n uts to secure the backplate to the pedestal (see Figure 3). Wall Mounting The RE-1 Entry System can be mou[...]

  • Page 8

    6 TELEPHONE WIRING OPTIONS Shared Line This is the standard confi guration. The telephone line is routed through the RE-1 to the house phones. Pressing the Call button on the RE-1 will cause the RE-1 to disconnect the house phones from the telephone company line and generate a ring signal that is heard on the house phones. Dedicated Line Pressing [...]

  • Page 9

    7 MUL TIPLE UNIT INST ALLA TIONS Any of the f our basic operation modes (Shared Line, Dedicated Line , Intercom, and Ring Down) ma y be used with multiple RE-1s in the same installation. The telephone line wiring is “daisy chained” (the telephone line routes through one unit to the next) as sho wn below . Alwa ys connect the telephone line + to[...]

  • Page 10

    8 CONTROL WIRING Gate Control 1. Route two wires between the gate and the RE-1. Connect the gate operator’ s OPEN ter minals to the RE-1 Relay #1 COM & N.O . terminals. ✦ NO TE: For operator wiring specifi cs, refer to the gate oper ator’ s wiring diagram. 2. If an access ke yswitch is required ref er to the Optional K eys witch section [...]

  • Page 11

    9 POWER, BA TTERY , & GROUND WIRING Pow er Wiring ✦ NO TE: DO NO T APPL Y PO WER UNTIL THE IN S T ALLA TION I S COMPLETE. 1. Route two wires between the RE-1 and the pow er transformer . • F or power wire runs up to 100 feet, use 18 A WG, THHN 600-volt insulated wire. • F or power wire runs up to 200 feet, use 16 A WG, THHN 600-volt insul[...]

  • Page 12

    10 OPTIONAL KEYSWITCH A ke yswitch can be installed in the RE-1 Entry System to provide keyed access. The RE-1 case is designed to accept the f ollowing ke yswitch: KNO X COMP ANY MODEL 3 501 KNO X COMP ANY 800-552-5669 www .knoxbo x.com Keyswitch Installation 1. Disconnect the wiring har ness connector and remov e the antenna terminal block. Remov[...]

  • Page 13

    11 OPTIONAL CCTV CAMERA Linear’ s Model RE-BWC1 (P/N A CP00886A) CCTV camera can be installed inside the RE-1 Entry System. The camera provides a video signal for vie wing the area in front of the entry system. The camera is continuously po wered by the RE-1. The camera’ s infrared light emitters illuminate the area directly on front of the ent[...]

  • Page 14

    12 PROGRAMMING ACCESS The RE-1 can be programmed locally or remotely . The system’ s built-in progr amming software can be accessed on-site or off-site using a computer with any Internet browser . Without a computer , the RE-1 can be programmed from its main ke ypad, from any local T ouchT one® telephone connected to the same line, or from any r[...]

  • Page 15

    13 1. FROM CONTROL PANEL S ELECT "NETWORK CONNECTION S " THEN S ELECT "NEW CONNECTION WIZARD" 2. THE NEW CONNECTION WIZARD WILL S TART CLICK "NEXT" 3. NEW CONNECTION WIZARD - "NETWORK CONNECTION TYPE" S ELECT "CONNECT TO THE INTERNET" OPTION 4. NEW CONNECTION WIZARD - "GETTING READY" S ELE[...]

  • Page 16

    14 2. CLICK "DIAL" TO S TART THE CONNECTION 6. AFTER CONNECTING, S WITCH TO YOUR MICRO S OFT INTERNET EXPLORER BROW S ER S OFTWARE AND ENTER THI S ADDRE SS : http://192.16 8 .20.10/re1.html 3. THE MODEM WILL DIAL THE NUMBER CONNECTING TO THE RE-1 WITH WINDOWS XP™ 1. DOUBLE-CLICK ON DE S KTOP ICON TO LAUNCH THE CONNECTION WINDOW 5. THE R[...]

  • Page 17

    15 1. FROM THE S TART MENU, CLICK ON "CONNECT TO" SETTING UP A WINDOWS VISTA™ DIAL-UP NETWORK CONNECTION (PART 1) 2. CLICK ON " S ETUP A CONNECTION OR NETWORK" 3. CHOO S E " S ET UP A DIAL-UP CONNECTION" 4. CLICK ON THE MODEM TO BE U S ED FOR THE CONNECTION 5. FILL IN THE INFORMATION FOR THE CONNECTION 6. CLICK ON &q[...]

  • Page 18

    16 7. CLICK ON "CLO S E" SETTING UP A WINDOWS VISTA™ DIAL-UP NETWORK CONNECTION (PART 2) 8 . FROM THE S TART MENU, CLICK ON "CONNECT TO" AND S ELECT "RE-1" 9. IN THE CONNECT WINDOW, S ELECT "PROPERTIE S " 10. CLICK ON "CONFIGURE" AND UN-CHECK ALL HARDWARE FEATURE S 11. CLICK ON "OK" THEN[...]

  • Page 19

    17 1. CLICK ON "DIAL" S TART THE CONNECTION CONNECTING TO THE RE-1 WITH WINDOWS VISTA™ 2. THE MODEM WILL DIAL THE NUMBER 3. ONLY WHEN CONNECTING REMOTELY, AFTER THREE RING S , CLICK "CANCEL", WAIT 10 S ECOND S THEN REPEAT S TEP S 1-3. THE RE-1 WILL AN S WER THE PHONE ON THE S ECOND CALL ATTEMPT 5. AFTER CONNECTING, S WITCH TO [...]

  • Page 20

    18 LOCAL PROGRAMMING ACCESS Programming with a Local T elephone or the Unit’ s Keypad Star t with Step 1 below f or local programming with the unit’ s keypad or a local telephone. 1. Enter “ ### ” (unless the prog ramming prefi x has been changed) then the Master Programming Code (123456, unless it has been changed), then “ # ”. 2. Use[...]

  • Page 21

    19 PROGRAMMING REFERENCE PROGRAMMING CONTROL USAGE KEYSTROKES ENTER PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .###MASTER CODE# ESCAPE/CANCEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . * EXIT PROGRAMMING . . . . . . . . . . . . . . . [...]

  • Page 22

    20 BASIC SYSTEM PROGRAMMING Entering Programming Mode The 6-digit Master Programming Code (def ault = 123456) is used to enter Programming Mode from a local or remote telephone or the k eypad. Press: Master Code Master Code = the current 6-digit Master Programming Code Exiting Programming Mode Press: ✦ NO TE: The RE-1 will automatically exit Prog[...]

  • Page 23

    21 TRANSMITTER PROGRAMMING Adding T ransmitters Up to 24 groups of transmitters can be assigned common access privileges sharing the same one or two time zones. Up to 100 transmitters total in all groups combined can be used in each RE-1 system. Press: Number Facility Code Fir st ID Time Zone 1 Time Zone 2 Number = Number of transmitters in the gro[...]

  • Page 24

    22 Call Forw arding Featur e Default: OFF The call forw arding feature will allo w a visitor to contact the resident at the programmed telephone number instead of through the local telephone line. The f eature can be set to be active during a selected Time Zone or at all times. The telephone n umber programmed can contain an e xtension number and a[...]

  • Page 25

    23 Relay #2 Alternate Options Default: Access Relay Relay #2 can be used f or functions other than tr iggering a gate operator or door strike. Relay #2 can be programmed to shunt alarm contacts during Relay #1 activ ation or perf or m up to fi ve Alarm Functions. T wo PPN numbers are used to program the Rela y #2 options. Press: Role Role: 0 = Acc[...]

  • Page 26

    24 Keypad Beeps On/Off Default: On The default setting causes the main k eypad to beep when each k ey is pressed. The beeps can be disab led. Press: Keypad Beeps Ke ypad Beeps: 0 = Beeps OFF 1 = Beeps ON Relay #1 T one On/Off Default: Off The default setting does not cause the ann unciator to sound when Relay #1 is activated. The Relay #1 activ ati[...]

  • Page 27

    25 RE-1 OPERA TION Requesting Access with an Entry Code • Visitors hav e up to 40 seconds to key in their entry code. • Up to eight seconds are allowed between each k eystrok e. • All digits of the entr y code must be entered. Example: If the code is 0042, the user must enter “0 0 4 2”. • If the wrong key is pressed, pressing the ke y w[...]

  • Page 28

    26 RESIDENT PROGRAMMING QUICK REFERENCE Some of the programming PPN’ s may be commonly used b y the resident. Following are quic k references to the k eystrok es required. ✦ NO TE: The “###” is the default command prefi x. The follo wing example assumes that the def ault has not been changed. T o Enter Programming Mode Press: Master Code M[...]

  • Page 29

    27 SPECIFICA TIONS MECHANICAL Case dimensions: 6.45” W x 10.81” H x 3.74” D ELECTRICAL V oltage: 16 V olts AC or 12-24 Volts DC Current: 650 mA AC typical, 1300 mA AC maxim um Backup Battery: Exter nally charged 12-24 V olt DC source Backup Battery Current: with 12-volt backup battery 250 mA standby 600 mA ringing one phone 1100 mA maximum wi[...]

  • Page 30

    28 PROGRAMMING WORKSHEET S E N O Z E M I TS E N O Z E M I T S E N O Z E M I T S E N O Z E M I TS E N O Z E M I T S Y A D E V I T C AS Y A D E V I T C A S Y A D E V I T C A S Y A D E V I T C AS Y A D E V I T C AE M I T T R A T SE M I T T R A T S E M I T T R A T S E M I T T R A T SE M I T T R A T SE M I T D N EE M I T D N E E M I T D N E E M I T D N [...]

  • Page 31

    29 E D O C Y R T N EE D O C Y R T N E E D O C Y R T N E E D O C Y R T N EE D O C Y R T N E# Y A L E R# Y A L E R # Y A L E R # Y A L E R# Y A L E RE N O Z E M I TE N O Z E M I T E N O Z E M I T E N O Z E M I TE N O Z E M I TE D O C Y R T N EE D O C Y R T N E E D O C Y R T N E E D O C Y R T N EE D O C Y R T N E# Y A L E R# Y A L E R # Y A L E R # Y [...]

  • Page 32

    LINEAR LIMITED WARRANTY This Linear product is warranted against def ects in mater ial and workmanship for tw enty-four (24) months . The W arranty Expiration Date is labeled on the product. This w arranty e xtends only to wholesale customers who buy direct from Linear or through Linear’ s normal distr ibution channels. Linear does not warrant th[...]