A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Linear DVS-2400, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Linear DVS-2400 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Linear DVS-2400. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Linear DVS-2400 should contain:
- informations concerning technical data of Linear DVS-2400
- name of the manufacturer and a year of construction of the Linear DVS-2400 item
- rules of operation, control and maintenance of the Linear DVS-2400 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Linear DVS-2400 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Linear DVS-2400, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Linear service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Linear DVS-2400.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Linear DVS-2400 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    R A-2400 REMO TE ACCESS SOF T W ARE Reference Manual for Pr ogramming the D VS-1200, D VS-2400, DU AL-824 & D VS-2408 Super vised W ireless Secur ity Systems WRITER’S NO TE: This pub lication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporate[...]

  • Page 2

    T ABLE OF CONTENT S 1. GENERAL INFORMA TION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 SOFTW ARE DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 SYSTEM REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 3

    1 1 . 1 SOFTW ARE DESCRIPTION What is the RA-2400 Remote Access Soft ware? The RA-2400 Remote Access software is a communications prog ram designed to work with Linear’ s D VS Supervised Wireless Security Systems and other Linear products. The softw are runs on an IBM PC or compatible computer and connects to the console through the standard tele[...]

  • Page 4

    2 1 .2 S Y STEM RE QUIREMENT S Minimum System Requirements: IBM compatible 486 personal computer with 8 Mb RAM Windows 95/98/NT/ME/XP/2000 oper ating systems V GA monitor Name brand modem that is capab le of 300 baud (BELL 103 compatible) Hard disk drive with 10 Mb a vailab le space for the softw are plus 18K av ailable space f or each Account Pro?[...]

  • Page 5

    3 1 .3 PROG RAMMING OUTLINE Use the f ollowing programming outline to guide y ou through the steps required to set up the RA-2400 software and progr am a D VS-2400 Console. Many of the programming options a vailab le in the RA-2400 program can be left in their def ault settings, and do not need to be changed f or most installations. 1. SETUP RA-240[...]

  • Page 6

    4 1 .4 PROG RAM INST ALL A TION The RA-2400 Remote Access Program softw are is supplied on a CD- ROM. The installation program will create a directory on your hard disk drive. Be sure that you ha ve at least 10 megab ytes free on the hard disk f or the program and any Account Profi le fi les that you create. T o Install the Remote Access P rogram[...]

  • Page 7

    5 1 .5 TESTING THE MODEM Bef ore you run the Remote Access Program, be sure that the computer is running correctly and that the modem is installed and working properly . T o T est the Modem: Windows Control P anel can be used to test the modem and determine what COM por t it is connected to . ✦ Press ST ART , SETTINGS , CONTROL P ANEL. Double-cli[...]

  • Page 8

    6 2. O VERVIEW 2.1 ST ARTING THE PROGRAM . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2 NEW WINDO W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.3 MENU BAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.4 ACCOUNT PROFILE WINDO W O VERVIEW . . . . . . . . . . . . . . . . . 10 ☞ NOTE: Exper i[...]

  • Page 9

    7 2. 1 ST ARTING THE PROGRAM T o Run the P rogram: ✦ Press ST ART , point to PR OGRAMS, RA2400 and clic k on RA2400. 2.2 NEW WINDO W PURPOSE: T o select an Account Profi le template f or the type of unit being programmed. USER RESPONSE: ✦ Select D VS-2400/2408 (with the correct Console fi rmware v ersion number). ✦ Press OK. The RA-2400 pro[...]

  • Page 10

    8 2.3 MENU BAR PURPOSE: T o provide access to each of the progr ams sub-menus. The sub-menus that can be accessed from this menu are: File NEW T o select an Account Profi le template for the type of unit being programmed. OPEN Loads a sav ed Account Profi le into the RA-2400 workspace. Mul- tiple Account Profi les can be open at the same time in[...]

  • Page 11

    9 2.3 MENU BAR (CONTINUED) VIE W TOOL BAR When check ed, the tool bar is display ed. NO TE: The tool bar can be turned into a re-sizable fl oating tool bar window b y dragging it out of its dock ed location at the top of the workspace. The tool bar accesses many of the popular menu items . Hov er the mouse pointer ov er the tool bar button to see [...]

  • Page 12

    10 2.4 ACCOUNT PROFILE WINDO W O VERVIEW PURPOSE: T o enter data and make changes to an Account Profi le and customize it f or a specifi c installation. MENU TREE Used for selecting the v arious data entr y fi elds in the Account Profi le. Clic king on the plus (+) symbols expands the br anches of the menu tree. Clicking on the minus (-) symbol[...]

  • Page 13

    11 3. COMMUNICA TIONS SETUP 3.1 COM PORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.2 SPEAKER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.3 CONNECTION OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.4 MODEM INITIALIZA TION STRING . . . . . . . . . . . . . . . . . . . . [...]

  • Page 14

    12 3. 1 COM POR T PURPOSE: T o select which communications (COM) por t the modem is connected to . USER RESPONSE: ✦ Click on the COM por t number ( 1 , 2 , 3 , or 4 ) that the modem is connected to . ☞ NOTE: See the TESTING THE MODEM Section (1.5) of this manual f or deter mining the proper COM por t number . 3.2 SPEAKER PURPOSE: T o set how th[...]

  • Page 15

    13 3.3 CONNE C TION OPTIONS PURPOSE: T o choose how the modem will connect to the D VS-2400 Console. Remote Dialing dials a telephone number with the method chosen (tone or pulse) to connect with the Console ov er a standard telephone line. Local Cable Connection does not dial a telephone n umber , but communicates with the Console wired directly t[...]

  • Page 16

    14 3.4 MODEM INITIALIZA TION STRING PURPOSE: Used to choose whether the def ault or a custom initialization “string” is sent to confi gure the modem ( a “string” is a series of characters that are commands f or the modem ). Modem’ s use initialization strings to setup their speed, data type, and other options . The RA-2400 sends the init[...]

  • Page 17

    15 4. CREA TING A CUST OM ACCOUNT PROFILE 4.1 NEW WINDO W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.2 CUSTOMER INFORMA TION . . . . . . . . . . . . . . . . . . . . . . . . . 17 4.3 CONSOLE ACCESS CODES . . . . . . . . . . . . . . . . . . . . . . . . . 18 4.4 CONSOLE ARM/DISARM. . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 18

    16 4. 1 NEW WINDO W PURPOSE: T o select an Account Profi le template f or the type of unit being programmed. USER RESPONSE: NEW ✦ Click on NEW icon on tool bar or select NEW from the FILE menu. ✦ Select D VS-2400/2408 (with the correct Console fi rmware v ersion number). ✦ Click OK. The new Account Profi le will appear as a star ter templa[...]

  • Page 19

    17 4.2 CUST OMER INF ORMA TION PURPOSE: F or enter ing customer inf or mation specifi c to the installation for the Account Profi le. USER RESPONSE: CUSTOMER ☞ NOTE: All fi elds are optional and do not ha ve to be fi lled in. This inf or mation is not sent to the Console. ✦ Enter a CUSTOMER ID f or the installation. ✦ Enter the customers [...]

  • Page 20

    18 4.3 CONSOLE ACCESS CODES PURPOSE: T o install a Master Access Code and up to 5 Restricted Access Codes, a Duress Code, and a P age Aler t Code. CODE DEFINITIONS: MASTER ACCESS CODE ✦ Allows ar ming and disarming the Console. Allows access to all progr amming options. RESTRICTED ACCESS CODE ✦ Allows ar ming and disarming the Console. Allows e[...]

  • Page 21

    19 4.4 CONSOLE ARM/DISARM PURPOSE: T o select which modes any remote arm/disar m transmitters will s witch to . Also f or selection of fi ve arm/disar m options. USER RESPONSE: ARM/DISARM ✦ T OGGLE-ARM TO: Select either HOME or A W A Y to choose the mode that any remote arm/disar m transmitters will arm the Console to. ✦ T OGGLE-DISARM TO: Sel[...]

  • Page 22

    20 4.5 CONSOLE ENTR Y/EXIT PURPOSE: T o select dela y times and other options for the Console’ s exit and entry dela ys. USER RESPONSE: ENTRY/EXIT ✦ ENTR Y DELA Y : T o change the entr y delay , enter a dela y time from 20 to 255 seconds. ✦ EXIT DELA Y : T o change the exit dela y , enter a delay time from 20 to 255 seconds. ✦ BEEP DURING E[...]

  • Page 23

    21 4.6 CONSOLE AL ARMS PURPOSE: F or setting the wa y the burglar y , emergency and fi re sirens w ork. Also sets the options f or the home-automation output dur ing and after alarms. USER RESPONSE: ALARMS ✦ BURGLAR Y ALARM: Select SILENT to disable the b urglar y siren or select SIREN FOR SET TIME for a timed siren after activ ation. With timed[...]

  • Page 24

    22 4. 7 CONSOLE HOME-AUT OMA TION OUTPUT PURPOSE: F or setting the wa y the home-automation output functions. USER RESPONSE: HOME AUTOMA TION-OUTPUT ✦ WHEN TRIGGERED: Select T OGGLES to cause the home-automation output to s witch between on & off with each activation. Select A CTIVE FOR SET DURA TION f or a timed home-automation output and en[...]

  • Page 25

    23 4.8 CONSOLE AUDIO PURPOSE: T o select how the V oice Board operates . NO TE: The Model VB-2 (for 2-way audio) or VB-3 V oice Board must be installed to use these options . Selects the audio mode f or monitoring with the Console’ s microphone and communicating through the Console’ s speak er to the subscriber. Controls the human voice prompts[...]

  • Page 26

    24 4.9 SENSORS PURPOSE: T o displa y and edit sensors installed in the Console’ s memor y . Up to 24 sensors ma y be installed, each with its own type, restore and supervision options. The status of the sensor selected is also display ed. ☞ NOTE: T o display and edit sensors installed in the Console , the sensor data must fi rst be receiv ed f[...]

  • Page 27

    25 4.9 SENSORS (CONTINUED) PERIMETER: Sensor will instantly trigger the burglary siren and repor t the burglary code to the Central Station in Home or A way Mode . Sensor will sound chime in Chime Mode . ENTR Y/EXIT: Sensor uses the e xit/entr y delay and can trigger the b urglar y siren and repor t the burglary code to the Central Station in Home [...]

  • Page 28

    26 4. 1 0 COMMUNICA T OR MAIN PURPOSE: F or confi guring the Console’ s communicator f or mat, dialing method, remote access pass word, dialing delay , and auto ans wer options. USER RESPONSE: COMMUNICA TOR MAIN ✦ Check the ON box to enable the comm unicator in the Console. ☞ NO TE: Y ou may want to turn the communicator off while testing th[...]

  • Page 29

    27 4. 1 1 COMMUNICA TOR ROUTING AND NUMBERS PURPOSE: F or confi guring the Console’ s communicator account number , trouble repor t routing, and telephone numbers. USER RESPONSE: ACCOUNT NUMBERS ✦ Enter a four digit account number f or the communicator f or mat used. TROUBLE REPORT ROUTING ✦ Select TROUBLE REPORTS TO PRIMAR Y AND SECOND ARY [...]

  • Page 30

    28 4. 1 2 COMMUNICA T OR ENABLED REPORT S PURPOSE: F or confi guring the Console condition repor ting options. USER RESPONSE: ENABLED REPORTS ✦ FORCE-ARM: Check this bo x to cause the communicator to report arming of the Console to Aw ay Mode with an open and b ypassed sensor . ✦ CONSOLE TROUBLE: Chec k this box to report low Console backup ba[...]

  • Page 31

    29 4. 1 3 COMMUNICA T OR 4 BY 2 F ORMA T ☞ NOTE: Section 4.13 per tains to the 4 by 2 communicator f or mat only . PURPOSE: F or confi guring how the 4 by 2 f ormat will repor t to the Central Station. General repor ting or P oint-to-P oint reporting methods are availab le for the 4 by 2 f ormat. GENERAL REPORTING: General reporting can send fi[...]

  • Page 32

    30 4. 1 3. 1 4 B Y 2 POINT-T O-POINT AL ARM CODES PURPOSE: T o view and edit the 24 sensor/z one alar m repor t codes. ☞ NOTE: 4 by 2 P oint-to-P oint Repor ting must be selected (see Section 4.13) f or these codes to repor t. USER RESPONSE: ZONE CODES ✦ Enter a new two-digit alarm code for an y sensor/zone that needs to be changed. ☞ NOTE: E[...]

  • Page 33

    31 4. 1 3.2 4 B Y 2 POINT-T O-POINT TROUBLE CODES PURPOSE: T o view and edit the 24 sensor/z one trouble repor t codes. ☞ NOTE: 4 by 2 P oint-to-P oint Repor ting must be selected (see Section 4.13) f or these codes to repor t. USER RESPONSE: ZONE CODES ✦ Enter a new two-digit troub le code for an y sensor/zone that needs to be changed. ☞ NOT[...]

  • Page 34

    32 4. 1 3.3 4 B Y 2 POINT-T O-POINT ARMING (CLOSING) CODES PURPOSE: T o view and edit the f orce arming repor t code. This repor t is sent when f orce ar m is enabled (Section 4.12) and the system is armed with any open sensors that hav e been bypassed. ☞ NOTE: With either reporting method, the force arming code is the same. USER RESPONSE: ACCESS[...]

  • Page 35

    33 4. 1 3.4 4 B Y 2 POINT-T O-POINT DISARMING (OPENING) CODES PURPOSE: T o view and edit the duress report code. This repor t is sent when the system is armed or disar med using the duress access code. ☞ NOTE: With either reporting method, the duress code is the same. USER RESPONSE: ACCESS CODES (OPEN) ✦ DURESS: Enter a new tw o-digit duress co[...]

  • Page 36

    34 4. 1 3.5 4 B Y 2 CONSOLE AL ARM CODES PURPOSE: T o view and edit the fi ve Console report codes. These codes are sent f or Console ev ents such as the Console emergency button, fi re b utton, Console low battery and batter y restore. The cancel report occurs when the Console is disarmed dur ing an alar m. ☞ NOTE: These repor t codes are sent[...]

  • Page 37

    35 4. 1 3.6 4 B Y 2 G ENERAL AL ARM CODES PURPOSE: T o view and edit the f our general alarm codes and the general trouble code. ☞ NOTE: 4 by 2 General Reporting must be selected (see Section 4.13) f or these codes to repor t. USER RESPONSE: 4 BY 2 GENERAL ALARM CODES ✦ Enter a new one or two-digit repor t code for an y general alarm code that [...]

  • Page 38

    36 4. 1 4 ADEMCO CONT AC T-ID REPORT CODES The Ademco Contact-ID repor ting codes are pre-defi ned and cannot be changed. These repor ting codes are provided as ref erence. The Ademco Contact-ID e xtended repor t codes indicate the sensor number that triggered the ev ent. Console e vents report with a “000” e xtended code. ☞ NOTE: Ademco Con[...]

  • Page 39

    37 5. SENDING AND RE CEIVING CONSOLE D A T A 5.1 ACCESSING THE SEND/RECEIVE WINDOW . . . . . . . . . . . . . . . . 38 5.2 CHOOSING AN ACCOUNT PROFILE . . . . . . . . . . . . . . . . . . . . 39 5.3 CONNECTING T O A CONSOLE . . . . . . . . . . . . . . . . . . . . . . . 40 5.4 SENDING DA T A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 40

    38 5. 1 ACCESSING THE SEND/RE CEIVE WINDOW PURPOSE: F or enter ing data required to connect to a D VS-2400 Console and to control the connection. Monitors the status of the communication between the RA-2400 and the D VS-2400. USER RESPONSE: ✦ An Account Profi le fi le m ust be open before the Send/Receiv e window can be accessed. Use the OPEN..[...]

  • Page 41

    39 5.2 CHOOSING AN ACCOUNT PROFILE PURPOSE: F or selecting which Account Profi le open in the workspace will be used when connecting to a Console. The Account Profi le selected automatically fi lls in the Console’ s Phone Number and P assword Fields using inf or mation already entered in the profi le (see Section 2.4). USER RESPONSE: CHOOSE A[...]

  • Page 42

    40 5.3 CONNE C TING T O A CONSOLE PURPOSE: Causes the RA-2400 to connect to the D VS-2400 Console. The RA-2400 will tr y to connect to the Console either locally or remotely , depending on the Communications Setup (see Section 3.3). ☞ NOTE: The Communications Setup can be revie wed b y pressing the COMM SETUP ... button in the Send/Receiv e windo[...]

  • Page 43

    41 5.3 CONNE C TING T O A CONSOLE (CONTINUED) CONNECTING LOCALL Y ✦ V er ify that the modem’ s LINE jack is connected to the Console’ s T&R T erminals with a cable. ✦ V er ify that the Console is in T est Mode. ✦ Click the CONNECT button. The Communication Status area will show the progress of the connection. W AIT UNTIL THE TIMEOUT T[...]

  • Page 44

    42 5.4 SENDING D A T A PURPOSE: F or transferring data from an Account Profi le to a D VS-2400 Console. ☞ CA UTION: Receiving the data from the Console will ov erwr ite the data in the Account Profi le. If you ha ve made changes to the Account Profi le, sa ve the profi le , then send the profi le to the Console bef ore receiving the data int[...]

  • Page 45

    43 5.5 RE CEIVING D A T A PURPOSE: F or transferring data from a D VS-2400 Console to an Account Profi le. ☞ CA UTION: Receiving the data from the Console will ov erwr ite the data in the Account Profi le. USER RESPONSE: RECEIVING ✦ Click the RECEIVE D A T A FROM CONSOLE b utton. The Communications Status area will indicate the progress and s[...]

  • Page 46

    44 5.6 CHANGING THE CONSOLE’S MODE PURPOSE: T o remotely view and change the oper ating mode of the Console. USER RESPONSE: ARMING MODE ✦ View the current operating mode of the Console in the ARMING MODE displa y area. ✦ T o change the current operating mode of the Console, select the desired mode button ( OFF , CHIME , HOME , or AWA Y ) in t[...]

  • Page 47

    45 5. 7 DISCONNE C TING FROM THE CONSOLE PURPOSE: T o end the programming session and disconnect the modem from the Console. USER RESPONSE: DISCONNECTING ✦ When fi nished communicating with the Console, clic k on the DISCONNECT button. The Communications Status area will show Not Connected when the Console has been disconnected. DISCONNECT BUTT [...]

  • Page 48

    46 5.8 CLOSING RA-2400 PURPOSE: T o sav e the active Account Profi le(s) and quit the RA-2400 program. USER RESPONSE: ✦ F rom the FILE menu, choose EXIT . ✦ T o sav e while exiting, in the SA VE CHANGES? window clic k YES . If the active Account Profi le is the def ault template, select a location and new name for the fi le and clic k SA VE [...]