Liebert EM manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Liebert EM, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Liebert EM one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Liebert EM. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Liebert EM should contain:
- informations concerning technical data of Liebert EM
- name of the manufacturer and a year of construction of the Liebert EM item
- rules of operation, control and maintenance of the Liebert EM item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Liebert EM alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Liebert EM, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Liebert service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Liebert EM.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Liebert EM item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Monitoring For Bu siness-Critical Con tinuit y Li eb er t O p en Com m s ™ EM User Ma nual[...]

  • Page 2

    [...]

  • Page 3

    i T ABLE OF CONTENTS 1.0 I NTRODUCTI ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.1.1 Dimensions and Mounting Overview - EM[...]

  • Page 4

    ii 5.0 G ETTING S TA R T E D W ITH THE W EB I NTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5.1 Open the Web Interface and Log In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5.2 View Summary Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 5

    iii FIGURES Figure 1 Front view (EM PDU & vEM-14 controlle rs shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 2 Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 3 Indicators on front of unit .[...]

  • Page 6

    iv[...]

  • Page 7

    Introd uction 1 1.0 I NTRODUCTION The Liebert OpenComms™ EM is a compact, half-duplex de vice designed t o mo nitor temperature, humidity, water dete ction and contact closure and not ify pe rsonnel when those con ditions exceed user-defined limits. The OpenComms EM is available in several models, whic h vary in size and number and types of ports[...]

  • Page 8

    Introd uction 2 1.1 Overview The OpenComms EM features indicator li ghts on the front, as shown in Figure 1 . Figure 1 Front view (EM PDU & vEM-14 contr ollers shown) 1.1.1 Dimensions and Mounting Overview - EM & EM PDU Controll ers • The unit is 4.75" wide, x 2.5" deep x 1.625" high (120.7 x 63.5 x 41.3mm). • The unit ma[...]

  • Page 9

    Introd uction 3 1.1.3 Connectors on Back of Unit The back of the OpenComms E M, shown in Figure 2 , has an input p ower so urce, sensor ports, a modem port and an Ethernet port. The EM PDU an d vEM-14 controllers have serial ports, and vEM-14 controllers also have 10 dry contact inputs. Figure 2 Rear view T able 1 Description of indicators and co n[...]

  • Page 10

    Introd uction 4 1.2 Indicators The front of the OpenComms EM has in dicators that show input power to the unit and the status of various connections, as shown in Figure 3 and descri bed in Table 2 . Figure 3 Indicators on front of unit EM CONTROLLER EM PDU CONTROLLER vEM-14 CONTROLLER T able 2 Indicators summary Indicator Type Indicator Label on Mo[...]

  • Page 11

    Installation 5 2.0 I NST ALLATION This section provides instru ctions for installing, mounting and connecting power and other cables to the OpenComms EM. 2.1 Inst allation Considerations The OpenComms EM must be installed indoors where el ectrical service is available. The unit sho uld be placed where it can be easily accessed for connecti ng the u[...]

  • Page 12

    Installation 6 2.2 Decide on Placement of the OpenComms EM The unit may either be placed on a level surface or mounted on a w all, depending on the user’s appli- cation and the location of equipm ent to be connected and monitored. vEM-14 controllers may also be mounted in a rack. • If placing the unit on a level surface, such as a shelf or a de[...]

  • Page 13

    Installation 7 2.2.2 Mounting the Unit on a W all or in a Ra ck (vEM-14 Controllers) The vEM-14 controller may be mounted on a wall or in a rack, such as the Liebert Foundation. The unit has four holes on each side, as shown in Figure 5 . Figure 5 Mounting - vEM-14 Controllers After dete rmining wh ere to place the unit, check to ensure that yo u h[...]

  • Page 14

    Installation 8 2.3 Make Connections All ports are on the back of the OpenComms EM. The port placement and port labels diff er for each model. Refer to Figure 2 for your mode l. 2.3.1 Connect Power to the Unit • Connect the DC power adapter to the DCN/Powe r po rt on the back of the OpenComms EM, as shown in Figure 2 . When power is connected, the[...]

  • Page 15

    Assign an IP Address 9 3.0 A SSIGN AN IP A DDRESS After connecting the OpenComms EM device to your networ k, the next step is to iden tify the device to the network by assigning an IP address. Consult Y our Network Administrator Consult your network administrator to obtain an IP address that is appropriate for your network, as well as a subnet mask[...]

  • Page 16

    Assign an IP Address 10 3.2 Use ARP to Assi gn an IP Address This method may be preferable if you are not usi ng a Microsoft host. To use the ARP command: 1. Open a command prompt. In Wind ows, one way to do this is: • Click on the Start button, then on Run . • In the Run window, enter cmd in the Open box, then click OK . 2. At the command prom[...]

  • Page 17

    Web Interface Overview 11 4.0 W EB I NT ERFACE O VERVIEW This section provid es a quick look at th e OpenComms EM Web interface and the viewing and con figu- ration functions accessi ble through tabs at th e top of the window. For step-by-step instruct ions on using the Web interface, proceed to 5.0 - Getting Started With the Web Interface . 4.1 Ma[...]

  • Page 18

    Web Interface Overview 12 4.2 T abs The tabs at the to p right of the Web inte rface wi ndow provide access to al l the functions of the OpenComms EM device. Table 5 summarizes these functions and wh ere to find more info rmation. 4.3 Color-Coded S t atus The Web interface uses color coding to indicate the status of sensors co nnected to the unit, [...]

  • Page 19

    Web Interface Overview 13 4.4 Thresholds in the W eb Interface The OpenComms EM collects data from conne cted se nsors at regular intervals. When a reading crosses a user-defined threshold: • The sensor’s status changes. • Alerts are sent—if the unit is confi gured for e-mail, pager or SNMP trap alerts. 4.4.1 T emperature/Humidity Se nsor T[...]

  • Page 20

    Web Interface Overview 14 4.4.3 MP Advanced Power S trip Thresholds When using the OpenComms EM to monitor MP Advanc ed Power Strips, you ma y set thresholds that will trigger alerts for power, voltage, current and temperatur e sensors in each power strip. Each sensor has four thresholds: High Critical, High Warnin g, Low Warning and Low Critic al.[...]

  • Page 21

    Web Interface Overview 15 4.5 Sensor Names and S t atus The Web interface displays four items ab out sensor s in all windows available through the Summary, Sensors and Power tabs, as shown in Table 10 . The sensor’s Name is an optional user-d efined description; the Description is created at the factory and cannot be changed. The Status and Curre[...]

  • Page 22

    Getting Started W ith the W eb Interface 16 5.0 G ETTING S T ARTED W ITH THE W EB I NTERFACE Once the unit is properly installed, you can view its Web interface usin g an Internet browser. This section provides step -by-step instructions on how to open the Web interface, log in, v iew monitoring data and v iew or change conf igur ation settings for[...]

  • Page 23

    Getting Started W ith the W eb Interface 17 5.2 V iew Summary Dat a The Summary window provides a quic k look at the current status of all conn ected devices, as shown below. This window also has a Log Out button to exit the Web interface. To access the Summary window, log in (see 5.1 - Open the Web Interface and Log In ) and: •C l i c k o n t h [...]

  • Page 24

    Getting Started W ith the W eb Interface 18 5.3 Sensors Window The Sensors tab provides acces s to sens or-related data and settings, in cluding: • Setting thresholds that will tr igger alerts for each sensor (see 5.3.1 - Configure Sensors ) • Creating displa y names for any sensor (see 5.3.2 - Create or Change Sensor Names ) • Viewing graphs[...]

  • Page 25

    Getting Started W ith the W eb Interface 19 5.3.2 Create or Change Sensor Names The Sensor Names feature allo ws you to create a name to help identify a sens or. This name is dis- played throughout the Web interface an d in notifications sent by pager or e-mail. To access the Sensor Names wind ow, log in (see 5.1 - Open the Web Interface and Log In[...]

  • Page 26

    Getting Started W ith the W eb Interface 20 5.3.3 View Sens or Graphs The OpenComms EM sensor data may be viewed in gr aphic format, along wi th the sensor’s upper and lower alarm limits, as described i n 5.3.1 - Configure Sensors . The OpenComms EM stores up to 1,440 data sample s for each sensor. Sensor data samples can be stored at intervals o[...]

  • Page 27

    Getting Started W ith the W eb Interface 21 Figure 6 Sensor graph - humidit y sensor example The line graph shows the selected senso r’s readings (black) chronologically from left to right—the most current reading is on the fa r right—as well as Warning (yellow) and Critical (red) limits. •U s e t h e All or Limit button to change the scale[...]

  • Page 28

    Getting Started W ith the W eb Interface 22 5.4 Power Window (EM PDU & vEM-14 Controllers) The Power tab provides access to MP Advanced Po wer Strips connected to the OpenComms EM, including : • Turning receptacles on or off—all at once, individually or in pairs (see 5.4.1 - Control Receptacles ) • Setting thresholds that will trigger ale[...]

  • Page 29

    Getting Started W ith the W eb Interface 23 Link the Controls of T wo Receptacles Two receptacles may be linked for simultan eous cont rol. The receptacles may be on the same power strip or on two different power strips. When two receptacles are linked, th e Connections column dis- plays the link as x: y , where x is the OpenComms EM serial port n [...]

  • Page 30

    Getting Started W ith the W eb Interface 24 5.4.2 Configure Thresholds You may set thresholds that will tr igger alerts for power, voltage, current and temperature sensors in each power strip. To do this: • In the left side of the Power Data window, shown above, select a po wer strip (Port 1 or 2) . • Click on one of the blue links— Power , V[...]

  • Page 31

    Getting Started W ith the W eb Interface 25 5.4.3 View Power S trip Graphs Power strip data may be viewed in graph ic format, similar to those of sens or data. To access the Power Strip Graphs window (see 5.4.1 - Control Receptacles for more details): • Click on the Power tab at the top of the Web interfac e. • Select a port from the left s ide[...]

  • Page 32

    Getting Started W ith the W eb Interface 26 5.4.4 Create or Change Port Names The Port Names fe ature allows you to create a name to help iden tify a serial port. This name is dis- played throughout the Web interface an d in notifications sent by pager or e-mail. To access the Port Names window, log in (see 5.1 - Open the Web Interface and Log In )[...]

  • Page 33

    Getting Started W ith the W eb Interface 27 5.5 Alert s Window The OpenComms EM may be configured to send alerts by e-mail or dial page rs to notify personnel when a sensor reading crosses a thre shold, either entering a warning or critical state or returning to normal status. See 4.4 - Thresholds in the Web Interface for more information. The Aler[...]

  • Page 34

    Getting Started W ith the W eb Interface 28 5.5.2 Modem Setup The OpenComms EM may be configured to send a numeric message to a pager. Note: The unit requires an ext ernal modem to send pager alerts. The modem port is set at 9600 baud, no parity, 8 data bits and 1 stop bit. For de tails on co nnecting the unit to a modem, see 6.1 - Modem Setup and [...]

  • Page 35

    Getting Started W ith the W eb Interface 29 5.5.3 SNMP T rap Alert s Setup The OpenComms EM may be configured to send SNMP trap alerts to a computer whenever the status of a sensor changes from normal to a warning or critical state, a s well as a return-to-normal alert when the reading fall s within the normal range. Thes e alerts may be sent to up[...]

  • Page 36

    Getting Started W ith the W eb Interface 30 5.6 Security Window To protect configuration settings from unauthorized users, the Web interface allows you to set up users with different levels of access. • A user with Administration privileges has full access, including creatin g and modifying other user accounts. •U s e r s w i t h Read/Write acc[...]

  • Page 37

    Getting Started W ith the W eb Interface 31 5.6.2 Create a New User Account (Administrators Onl y) An administrator may create user accounts for up to 50 users, includ ing th e administrator account. Only users with administrative pr ivileges may create user accounts. To do this, log in as an adminis trator (see 5.1 - Open the Web Interface and Log[...]

  • Page 38

    Getting Started W ith the W eb Interface 32 5.6.3 Modify an Existing Account (Administrators Only) Users with adm inistrative priv ileges may change all options on all users’ accounts , including their own. Users without administrative access are preven ted from chan ging anything except their ow n password; for details, see 5.6.4 - Change Passwo[...]

  • Page 39

    Getting Started W ith the W eb Interface 33 5.6.4 Change Password (Users with Read/Wr ite access) Users with Read or Read & Write access may change their password but no other user account infor- mation for their own accounts or those of other users. To change your own password, log in (see 5.1 - Open the Web Interface and Log In ) and: • Cli[...]

  • Page 40

    Getting Started W ith the W eb Interface 34 5.7 Sys Info Window The OpenComms EM may be configured to send alerts by e-mail or dial page rs to notify personnel when a sensor reading crosses a thre shold, either entering a warning or critical state or returning to normal status. See 4.4 - Thresholds in the Web Interface for more information. The Sys[...]

  • Page 41

    Getting Started W ith the W eb Interface 35 5.7.2 SNMP Information To access the SNMP Information window, log in (see 5.1 - Open the Web Interface and Log In ) and: • Click on the Sys Info tab at the top of the Web interface, as shown below. • Click on the SNMP Information link on the left side of the wind ow. The right side of the window displ[...]

  • Page 42

    Getting Started W ith the W eb Interface 36 5.7.3 Dat a Present ation To access the Data Presentatio n window, log in (see 5.1 - Open the Web Interface and Log In ) and: • Click on the Sys Info tab at the top of the Web interface, as shown below. •C l i c k o n t h e Data Presentation link on the left side of the wind ow. The right side of the [...]

  • Page 43

    Getting Started W ith the W eb Interface 37 5.7.4 Serial Ports To view the Serial Port 1 and 2 windows, log in (see 5.1 - Open the Web Interfac e and Log In ) an d: • Click on the Sys Info tab at the top of the Web interface, as shown below. •T h e Se rial Port 1 and Serial Port 2 links on the left side of the w indow determine which port infor[...]

  • Page 44

    Pinout Guides 38 6.0 P INOUT G UIDES 6.1 Modem Setup and Pinout Guide The OpenComms EM must be connected to a modem to send pa ger alerts when a se nsor reading crosses a user-defined threshold (see 5.5.2 - Modem Setup for more information). The unit is compatible with modems that have DB9 or DB25 serial COM ports. A proper cable must be constructe[...]

  • Page 45

    Downloadin g Firmware Updates 39 7.0 D OWNLOADING F IRMWARE U PD AT E S This section explains how to update the unit’s firmware. 1. The first step is to download the upgrade text file. To d o this, visi t Liebert’s Web site at http://www.liebert.com and go to the OpenComms EM section. Or contac t Li ebert Monitoring Application Supp ort at 1-80[...]

  • Page 46

    Specifications 40 8.0 S PECIFICATIONS T able 16 OpenComms EM specifications Power Requirement s EM & EM PDU controller vEM-14 controller NOTE Input 120 V AC, 60 Hz 12 0 V AC, 60 Hz If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Output 9 VDC, 500 mA, unregulated 9[...]

  • Page 47

    [...]

  • Page 48

    Ensuring The Hi gh Av ail abilit y 0f Mission-Critic al Dat a And Appli c ations. Emerson Net work P ower , the global leader in enabling business-critical continuity , ensures net work resiliency and adaptability through a family of technologies—inc luding Lieber t pow er and cooling technologies—that prot ect and suppor t business-critical sy[...]