Lennox Hearth X-FIRES-1000-LP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lennox Hearth X-FIRES-1000-LP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lennox Hearth X-FIRES-1000-LP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lennox Hearth X-FIRES-1000-LP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lennox Hearth X-FIRES-1000-LP should contain:
- informations concerning technical data of Lennox Hearth X-FIRES-1000-LP
- name of the manufacturer and a year of construction of the Lennox Hearth X-FIRES-1000-LP item
- rules of operation, control and maintenance of the Lennox Hearth X-FIRES-1000-LP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lennox Hearth X-FIRES-1000-LP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lennox Hearth X-FIRES-1000-LP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lennox Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lennox Hearth X-FIRES-1000-LP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lennox Hearth X-FIRES-1000-LP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Report No. 317-F-10-5 IN ST AL LA TI ON AN D OP ER A TIO N MA NU AL W ARNINGS • Hot! Do not touch! This appliance will be hot during operation and will retain heat for a while after shutting off the appliance. Severe burns may result. • Carefully supervise children in the same room as appliance. • Due to high temperatures, the appliance shoul[...]

  • Page 2

    2 1. 0 IM P OR T AN T SA FE TY A ND W AR NI NG IN FO RM A TI ON W ARNINGS If th e info rmat ion in th is man ual is not fo l- low ed ex actl y , a fire or ex plo sion ma y resu lt cau sin g pro pert y da mage , per sona l in jury or los s of lif e. IMPOR T ANT Rea d and unde rst and the se inst ruc tion s c ompl etel y bef ore in stal ling or ope [...]

  • Page 3

    3 2.0 GENERAL INFORMA TION This appliance is a high efficiency , unvented, flame effect gas heater . It provides radiant and convected warmth both efficiently and safely utilizing the latest type catalytic convertor burner technology . The appliance does not require a flue system of any type as the catalytic converter cleans the flue products [...]

  • Page 4

    4 6.0 BURN-IN PERIOD On initial light up of a new appliance, the ‘newness’ will burn off within the first few hours of operation. During this period some smoke may be emitted from outlet grill, this should be no cause for concern. Accord- ingly , the room should be well ventilated with all windows and doors open during this period. Depending o[...]

  • Page 5

    5 8.0 COMBUSTION AND VENTILA TION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventil ation air . The heater may be located in unusually tight construction provided the space is unconfined, or if confined, is provided with two permanent openi[...]

  • Page 6

    6 9.0 SITE REQUIREMENTS This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall. This appliance may be installed in any room in a home except bathrooms - or areas where large amounts of steam are likely to be generated. This appliance is approved for installation into a bedroom . It should be noted that hea[...]

  • Page 7

    7 Non-concealed gas connections may be made using the entry points at either end of the firebox or the one in the bottom of the firebox. A concealed gas connection may be made using the knock out hole in the center back of the firebox. Select the most appropriate entry point and knock out the relevant hole in both the firebox and the outer casi[...]

  • Page 8

    8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE After having selected the final mounting position of the appliance, taking into account the site requirements as specified in these instructions, the integrity of the wall, and the feasibility of the proposed supply pipe routing, the firebox of appliance may be secured to the wall. 12.0 MOUN[...]

  • Page 9

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 9 It is recommended that the burner height, where possible, should be approximately 4 ft. from the floor . This will give the best viewing position. When selecting the height, ensure that the clearance to the ceiling is 32" minimum, as specified on Page 6 . After selecting the final mounting[...]

  • Page 10

    10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 14.0 CHECKING THE BURNER There are no imitation fuel bed components, such as logs or rocks, to install. The appliance features a ribbon burner which is designed to produce a continuous band of flame over its length. The burner should be visually inspected to ensure it is free from any foreign [...]

  • Page 11

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 11 Figure 7a Bur ner (Ma nifo ld) Pre ssur e Figure 7b - Manifold and Inlet Pressure T aps Reg ula tor (Inl et) Pre ssu re S etti ng If the pressure is too high, the gas supply meter may be set incorrectly . This should be checked with the appliance running and if necessary reset by the gas suppl[...]

  • Page 12

    12 W ARNING Any cha nge to thi s hea ter or its con trol s can be dan ger ous. W ARNING No ad just men ts are to be ma de to the OD S pilo t sy st em . T amp er in g wi th thi s sys te m ca n be ext re me ly haz ard ous. W ARNING Y ou mu st ke ep con tro l are as, bu rne rs and circ ulat - ing a ir pass age ways of ap pli ance cl ean . Fai lure t o[...]

  • Page 13

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 13 21.0 CA T AL YSTS W ARNING Do not blo ck the cat aly sts or the app lia nc e out le t gr ill . Blo cka ge may cau se high car bon mon oxi de leve ls and /or bre akag e o f th e gl ass doo r as sem bly . It is recommended that the catalysts are inspected for signs of damage and dirt during rout[...]

  • Page 14

    14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lit with a piezo spark igniter . When lighting the pilot, foll[...]

  • Page 15

    15 24.0 TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections. • Air not fully purged. Purge supply or wait longer . • Spark grounding to metal work, reset gap correctly . • Blocked pilot, clean out internally . Pilot lights but then goes out • Severe rest[...]

  • Page 16

    16 25.0 REPLACEMENT P ARTS - X-FIRES-1000 5 4 15 Hardware NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 12 1 2 5 6 7 8 10 11 13 14 See ordering instructions on Page 20 WARNING CLEARANCES FROMCOMBUSTIBLE MATERIALS F860041/A The following clearances must be maintained at all times. Failure to do so may result in the risk of a fire. For full i[...]

  • Page 17

    17 26.0 POSITIONING OF FIELD REMOV ABLE P ARTS W ARNING Fai lur e to posi tio n the par ts in acc ord ance wi th the se diag ram s or fai lur e to use onl y pa rts spe cifi- cal ly a ppro ved with this h eat er may res ult in prop erty dama ge or per sona l in jury . Figure 13 4 off burner installation positions Figure 12 Glass Door Removal: Remov[...]

  • Page 18

    18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 27.0 SPECIFICA TIONS X-FIRE-1000 Surround Kits Cat. No. Model Description S hi p . W t . Ship. Volume H7226 X-FIRE-1000-L Limestone Surround 5 5 l b . 4. 5 8 c u . f t . H7227 X-FIRE-1000-G Granite Surround 5 5 l b . 4. 5 8 c u . f t . 39-7/16” 11-1/4” 25-1/4” 21-3/16” 15-3/4” 23-3/4[...]

  • Page 19

    19 Note: The actual dimensions are shown in millimeters. The fractional dimensions are converted from millimeters and are rounded to the nearest 1/16”. KEY : D1 = Dis tance from moun ting surfa ce to rea r ent ry poin t D2 = Dis tance from moun ting surfa ce to cen ter o f sid e ent ry poin t D3 = Dis tance from moun ting surfa ce to reg ulato r [...]

  • Page 20

    Printed in U.S.A. © 2007 Lennox Hearth Products P/N 506023-01 REV . C 05/2009 Lennox Hearth Products reser ves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. WARRANTY Y our gas a[...]