Lennox Hearth LMBV-36REN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lennox Hearth LMBV-36REN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lennox Hearth LMBV-36REN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lennox Hearth LMBV-36REN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lennox Hearth LMBV-36REN should contain:
- informations concerning technical data of Lennox Hearth LMBV-36REN
- name of the manufacturer and a year of construction of the Lennox Hearth LMBV-36REN item
- rules of operation, control and maintenance of the Lennox Hearth LMBV-36REN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lennox Hearth LMBV-36REN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lennox Hearth LMBV-36REN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lennox Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lennox Hearth LMBV-36REN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lennox Hearth LMBV-36REN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION INSTRUCTIONS MODELS Millivolt Models LMBV-36RMN LMBV-36RMP LMBV-36REN 3/22/2010 INST ALLER: Leave this manual with the appliance . CONSUMER: Retain this manual for future reference. INST ALLA TEUR: Laissez cette notice avec l'appareil. CONSOMMA TEUR: Conservez cette notice pour consul- tation ultérieure. WARNING: If the informa[...]

  • Page 2

    2 LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS T ABLE OF CONTENTS Introduction ...................................... page 2 Massachusetts and New Y ork Requirements .........................page 3 General Information .......................... page 3 Location .................................[...]

  • Page 3

    3 LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS Carbo n Monoxide Poisonin g: Early sign s of carbo n monoxid e poisonin g are simil ar to the flu wit h headac hes, diz zine ss and/ or nause a. If you have these signs, obtain fresh air immedi- ately . T urn off the gas supply to the appli ance [...]

  • Page 4

    4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS T ypical Locations See Figure 1 . In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to t[...]

  • Page 5

    5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS CLEARANCES Minimum clearance to combustibles for the appliance is as follows: sides and back - 0" (0 mm), oor - 0" (0 mm), adjacent wall - 0" (0 mm), ceiling - 64" (1625 [...]

  • Page 6

    6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS FRAMING SPECIFICA TIONS Figure 4 Figure 5 Figure 6 PRE-INST ALLA TION NOTES The fireplace may be installed directly on a combustible oor or raised on a platform of an appropriate height. Do[...]

  • Page 7

    7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS Figure 9 Figure 10 All appliances are equipped with a gas ex line and shutoff valve attached directly to the gas control valve. T o quickly and easily complete the gas line routing, use the [...]

  • Page 8

    8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS Figure 11 Figure 12 Step 6. Connect to Gas Line Make gas line connections. All codes require a shut -off valve moun ted in the supp ly line. Figure 15 illustrates two methods for connecting the[...]

  • Page 9

    9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS Figure 14 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be wired to a terminal that is opposite (across the outle[...]

  • Page 10

    10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS Electronic Appliance Checkout T o light the burner , turn ‘ON’ the optional remote wall switch and turn the gas control switch to the “ON” position. Ensure the ignitor lights the pilot[...]

  • Page 11

    11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS When satisfied that the appliance operates properly , proceed to finish the installation. Leave the control knob/lever in “ON” position and turn the remote switch “OFF .” Replace the[...]

  • Page 12

    12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS A TT A CH ING SAF ET Y IN OPE RA T ION WA RN IN GS It is required that the safety instructi[...]

  • Page 13

    13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS Figure 22 INST ALLA TION ACCESSORIES The following accessor y items are available for use in the installation of this appliance. Ou tsi de A ir K i ts M o de ls FO AK - 4 an d F OA K -4 LD Out[...]

  • Page 14

    14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS GAS CONVERSION KITS In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HA VING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS[...]

  • Page 15

    15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS Step 5. All Millivolt Systems – Attach manometer to the manifold side pressure test fitting and verify manifold pressure read s 3.5 inch es water column (0.87 kPa) for natural gas, and 10.0[...]

  • Page 16

    16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX MERIT ® SERIES B-VENT GAS FIREPLACES • 36" LMBV MODELS • INST ALLATION INSTRUCTIONS Printed in U.S.A. © 2006 by Lennox Hearth Products P/N 850040M Rev . C 07/2010 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, spe[...]