Lathem DDC4 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lathem DDC4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lathem DDC4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lathem DDC4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lathem DDC4 should contain:
- informations concerning technical data of Lathem DDC4
- name of the manufacturer and a year of construction of the Lathem DDC4 item
- rules of operation, control and maintenance of the Lathem DDC4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lathem DDC4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lathem DDC4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lathem service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lathem DDC4.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lathem DDC4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Digital Display Wall Clock DDC2 / DDC4 Seri es Installation & User's Guide[...]

  • Page 2

    OMNI:CHRON, m ini:mast er, Lathem and the Lathem logo are regi stered tradem arks of Lathem Tim e Corporation. Other product nam es mentioned i n this m anual may be trademarks of their respective companies and are hereby ac knowledged. WARNING: C hanges or m odifications to this pro duct not exp ressly approve d by the pa rty responsi ble for comp[...]

  • Page 3

    Table of Contents Introduc tion................................................................................................................... .................................. 1 Clock Oper ation ................................................................................................................ .............................. 1 Abo[...]

  • Page 4

    DDC4 (Double Mo unt - Ce iling) .................................................................................................. ........ 19 Setting the Tim e ............................................................................................................... ............................. 20 Time Form ats ..............................[...]

  • Page 5

    As a Count U p Timer ............................................................................................................ ................ 52 As a Count D own Timer .......................................................................................................... ............. 52 Appendix E - LTR-GPS Satellite Recei ver / Clock Sy n[...]

  • Page 6

    [...]

  • Page 7

    Page 1 Digital Display W all Clock Guid e Introduction The Digital Display Series Wall Clocks are de signed with 2-inch or 4-inch red LED displays that can be viewed from great distances; the 4-inch model as far a w ay as 100 feet, the 2-inch m odel from as far awa y as 50 feet. The bri ght red di splay shows the hour an d minutes an d can be confi[...]

  • Page 8

    Digital Display W all Clock Gu ide Page 2 About this Manual This manual will guide you through the installation, setup and wiring of your DDC Series Wall Clock. This manual cove rs the four avai lable DDC Series m odels. The availa ble model s and their des criptions a re: DDC2-RS / DDC4-RS Equipped with a 2-inch or 4-in ch display, these models ca[...]

  • Page 9

    Page 3 Digital Display W all Clock Guid e Optional Accessories VSE0050 Power Cord, 6 feet. D DC Series Wall Clo cks are shipped w ithout power cords. SAM0626 Double Ceiling Mount Kit for DDC2 or DDC4 Series SAM0630 Double W all Mount Kit for DDC2 Series SAM0625 Double W all Mount Kit for DDC4 Series VSE0052 Mounting Bracket for 3510 Hz Electronic R[...]

  • Page 10

    Digital Display W all Clock Gu ide Page 4 4 - #6 Lock Washers 4 - #6 Hex Nuts SAM0625 Kit (right) In cludes: 1 - Mounting Plate Assembly 2 - Modified En d Caps 1 - End Cap Support 2 - Chase Nipples 4 - #10 Screws 8 - #10 Lock Washers 4 - #10 Hex Nuts 4 - #6 Screws SAM0630 Kit (middle) Includ es: 1 - Mounti ng Plate Assem bly 2 - Modifie d End Caps [...]

  • Page 11

    Page 5 Digital Display W all Clock Guid e Configuring the DDC Series W all Clock Setting the DIP Switches - DDC2 / DDC4 Series DDC2 Remove the four phillip s head screws from the left or the right end cap and remove. Slide th e lens and circuit board assembly out of the case. Place the lens aside and care fully flip the circuit board assembly over [...]

  • Page 12

    Digital Display W all Clock Gu ide Page 6 DIP Switch Settings Table 1 - S1 (1-5) Seconda ry Clock Correctio n 1 2 3 4 5 Secondary Clock Selection 0=Closed 1=Open *=Factory Default 0 0 0 0 0 Stand Alone * 1 0 0 0 0 3-Wire Synchrono us 0 1 0 0 0 3-Wire Minute Impulse (59 th Minute) 1 1 0 0 0 3-Wire Minute Impulse (59 th Minute) Wi th 12 Hour Co rrect[...]

  • Page 13

    Page 7 Digital Display W all Clock Guid e Configuring RS485 Communications - DDC2/4-RS Series When multiple DDC2 (4)-RS Series Wall Clocks are installed as slave units to either the Lathem LTR4- 512 or LTR 8-512 Master, LTR0 Mini-M aster, Term inal Manage r Software or the OM NI:CHRO N Time Clock, the last clock on the line must have a shu nt insta[...]

  • Page 14

    Digital Display W all Clock Gu ide Page 8 When used as a RS485 clock, the master clock will send a signal to the wall clo ck every minute. The 9- Volt alkaline battery (not included) is optional in these types of installations. Battery Inst allation - DDC2 / DDC4 Series DDC2 Remove the four phillip s head screws from the left or the right end cap a[...]

  • Page 15

    Page 9 Digital Display W all Clock Guid e AC Return) Attach the ground wir e of the cord (normally g reen) to the green ground screw lo cated on the inside back of the case. Slid e the lens and circuit bo ard assembly back into the case, repla ce the end cap and secure with the four phillip s head screws. DDC4-RS Remove the two phillip s head screw[...]

  • Page 16

    Digital Display W all Clock Gu ide Page 10 Replacing an Existing DDC4 Wall Clock When replacing an older style DDC4 Wall Clock it will be necessary to remove any connectors used by the older style cl ock and at tach the wires to the ne w DDC Serie s Wall Cloc k as describe d above. Board Layout Diagram J2 Factory Defaul t Off J2 Install shunt on la[...]

  • Page 17

    Page 11 Digital Display W all Clock Gu ide Mounting - DDC2 / DDC4 Series The DDC Series Wall Clocks can be mounted directly to a wall, to a single gang outlet box, double hung from the wall or double hung from the ceiling. When deciding where the clock will be mounted, keep in mind that 115VAC power may be requi red dependin g on the installati on [...]

  • Page 18

    Digital Display W all Clock Gu ide Page 12 » Slide the lens and circuit board assem bly back into the case, replace the e nd cap and secu re with the four phillips he ad screws. DDC4 » After deciding the location wh ere the clock will be mounted, m ake two marks 12" apa rt and horizontal. Note: If mounting near a ceiling, make sure the holes[...]

  • Page 19

    Page 13 Digital Display W all Clock Gu ide DDC2 Note: If mounting near a ceiling, make sure the top of the single gang box is at least 2 1/4" away from the ceiling. Note: Make su re you have at least 10 1/2 " of side cle arance on one si de in order t o remove t he lens and circuit board assembly. » Remove the four phillip s head screws [...]

  • Page 20

    Digital Display W all Clock Gu ide Page 14 » Slide the front panel display back int o the ca se, replace the end cap and se cure with the two phillips head screws. Figure 3 Keyholes for wall mount Vent holes For 1/2" conduit For single gang box mount Double Mount - W all DDC2 Requi res optional m ounting kit (SAM063 0) DDC4 Requi res optional[...]

  • Page 21

    Page 15 Digital Display W all Clock Gu ide Note: The long dimension of the mou nting plate m ust be perpendi cular to the ground to a ssure proper alignment of wall clocks. See page 15, figure 4 fo r DDC2 detail s. See page 16, figure 5 fo r DDC4 detail s. DDC2 (Double Mount - Wall) » Remove the four ph illips head screws from the left and th e ri[...]

  • Page 22

    Digital Display W all Clock Gu ide Page 16 DDC4 (Double Mount - Wall) » Remove the two phillip s head screws from the left and the right end caps of the two DDC4 clocks and remove. Slide the front panel assemblies out of the cases and set aside. » Place the two DDC4 clocks back to back and sec u re by inserting a #10 screw through t he two key ho[...]

  • Page 23

    Page 17 Digital Display W all Clock Gu ide Double Mount - Ceiling Requires opt ional mount ing kit (SAM0626) Tools requi red for m ounting the cl ock: Flat blade screwdriver Phillips head screwdriver 15/16" o pen end wrench The double ceiling m ount plate attaches to a double or si ngle gang box installed securely in the ceiling. Required wiri[...]

  • Page 24

    Digital Display W all Clock Gu ide Page 18 DDC2 (Double Mount - Ceiling) Note: Make sure yo u have at least 10 1/2" of side cleara nce on one si de in order to remove the le ns and circuit board assembly. » Remove the four ph illips head screws from the left and th e right end caps of the two DDC2 clocks and remove. Slide the le nses and circ[...]

  • Page 25

    Page 19 Digital Display W all Clock Gu ide DDC4 (Double Mount - Ceiling) Note: Make sure you have at least 16" of side clear ance on one side in order to remove t he front panel assembly. » Remove the two phillip s head screws from the left and the right end caps of the two DDC4 clocks and remove. Slide the front panel assemblies out of the c[...]

  • Page 26

    Digital Display W all Clock Gu ide Page 20 Setting the T ime Time is set on the DDC Seri es Wall Cl ocks by de pressing buttons located on the left side of the front panel. There are tw o setting but tons, "H" for hour and "M' for mi nute. » To advance t he hour or m inute to the correct tim e one digit at a tim e press and rel[...]

  • Page 27

    Page 21 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring Appendix A - DDC2-RS / 4-RS Seco ndary Clock W iring Diagrams Note: See Ap pendix B for DDC2-RS- 24 / DDC4 -RS-24 wi ring. Stand-Alone (115VAC) GRND AC IN AC RTN BLK BLK Hour and Mi nutes must be se t manually. Us e of a 9Volt alkali ne battery is recom mended to a void resets after pow[...]

  • Page 28

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 22 3-Wire Synchronous (115VAC) H M BLU / WHT Run BRN / WHT BLK BLK Correction AC Return 115VAC From Master Cloc k To Other Cloc ks 6 7 8 Clock will correct minutes hourly at HH:59 and hour and m inutes twice daily at 5:59. Wiring applies to second ary wall clocks such as: Lathem type SS Ci[...]

  • Page 29

    Page 23 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring 3-Wire Synchronous (24VAC) 5 6 7 8 OPEN 1 2 3 4 Set switches 1-5 of S1 as shown. Indicates depr essed side of s witch To Other Cloc ks Clock will correct minutes hourly at HH:59 and hour and m inutes twice daily at 5:59. 24VAC From Master Cloc k H M BLU / WHT Correction BRN / WHT Return[...]

  • Page 30

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 24 3-Wire minute Impulse (59 th Minute) BRN / WHT GRND AC IN A C RTN A VIO / WHT YEL / WHT BLK BLK B C To Other Cloc ks 24VDC From Master Cloc k H M 115VAC Local Powe r OPEN 1 2 3 4 5 Clock must be set within 20 m inutes of actual time for master to synchronize. Use of a 9Volt alkaline bat[...]

  • Page 31

    Page 25 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring 3-Wire Minute Impulse (59 th Minute With 1 2 Hour Correction) B C 1 2 3 4 5 6 Clock will correct minutes hourly at HH:58 and hour and m inutes twice daily at 5:58. BRN / WHT GRND AC IN A C RTN A VIO / WHT YEL / WHT BLK BLK Wiring applies to second ary wall clocks such as: Lathem ISC 3-W[...]

  • Page 32

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 26 Standard Electric Synchronous 115VAC From Master Cloc k To Other Cloc ks H M BLU / WHT Run Correction BRN / WHT BLK BLK AC Return Clock will correct minutes hourly at HH:59 and hour and m inutes twice daily at 5:12. For 24VAC ap plications, us e wiring sh own on pa ge 18 6 7 8 Set switc[...]

  • Page 33

    Page 27 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring Standard Electric AR-2A 2-Wire Dual Voltage PC OPEN 1 2 3 4 5 6 Clock must be set to actual tim e. Use of a 9Vol t alkaline battery is recommended to avoid resets after power failures. 7 8 Set switches 1-5 of S1 as shown. Indicates depr essed side of s witch 24VDC / 48VDC From Master Cl[...]

  • Page 34

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 28 Standard Electric AR-2 2-Wire Dual Voltage PC OPEN 1 2 3 4 5 6 Clock must be set to actual tim e. Use of a 9Vol t alkaline battery is recommended to avoid resets after power failures. 7 8 Set switches 1-5 of S1 as shown. Indicates depr essed side of s witch 24VDC / 48VDC From Master Clo[...]

  • Page 35

    Page 29 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring Synchronous Wired 115VAC From Master Cloc k To Other Cloc ks H M BLU / WHT Run Correction BRN / WHT BLK BLK AC Return 6 7 8 OPEN 1 2 3 4 5 Set switches 1-5 of S1 as shown. Indicates depr essed side of s witch Clock will correct minutes hourly at HH:58 and hour and m inutes twice daily b[...]

  • Page 36

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 30 Simplex 59 th Minute Dual Motor 115VAC From Master Cloc k To Other Cloc ks H M BLU / WHT Run Correction BRN / WHT BLK BLK AC Return Clock must be set to proper hour. Clock will correct minutes hourly at HH:58. . Use of a 9Volt alkaline battery is recommended to avoid resets For 24VAC ap[...]

  • Page 37

    Page 31 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring Simplex 45 th Minute Dual Motor 115VAC From Master Cloc k To Other Cloc ks H M BLU / WHT Run Correction BRN / WHT BLK BLK AC Return Clock must be set to proper hour. Clock will correct minutes hourly at HH:45. . Use of a 9Volt alkaline battery is recommended to avoid resets For 24VAC ap[...]

  • Page 38

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 32 Edwards Dual Motor 115VAC From Master Cloc k To Other Cloc ks H M BLU / WHT Run Correction BRN / WHT BLK BLK AC Return Clock must be set to actual tim e. Use of a 9Vol t alkaline battery is recommended to avoid resets after power failures. For 24VAC ap plications, us e wiring sh own on [...]

  • Page 39

    Page 33 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring Standard Electric AR-3 3-Wire Minute Impulse To Other Cloc ks 24VDC / 48VDC From Master Cloc k BRN/ WHT 24 VDC Pulse Common YEL / WHT 48 VDC Correction GRND AC IN AC RTN BLK BLK VIO / WHT H M 115VAC Local Powe r Clock must be set to actual tim e. Use of a 9Vol t alkaline battery is reco[...]

  • Page 40

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 34 National Synchronous Wired 115VAC From Master Cloc k To Other Cloc ks H M BLU / WHT Run Correction BRN / WHT BLK BLK AC Return Clock will correct minutes hourly at HH:00 and hour and m inutes twice daily at 6:00. For 24VAC ap plications, us e wiring sh own on pa ge 18 7 8 Set switches 1[...]

  • Page 41

    Page 35 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring Stromberg Synchronous Wired (56 th Minute) To Other Cloc ks H M BLU / WHT Run Correction BRN / WHT BLK BLK AC Return 115VAC From Master Cloc k Clock will correct minutes hourly at HH:56 and hour and m inutes twice daily at 11:56 . For 24VAC ap plications, us e wiring sh own on pa ge 18 [...]

  • Page 42

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 36 Cincinnati D1 COMMON 1 2 3 4 5 Clock must be set within 20 m inutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is rec ommended t o avoid resets after power failures. OPEN 6 7 8 Set switches 1-5 of S1 as shown. Indicates depr essed side of s witch 24VDC / 6[...]

  • Page 43

    Page 37 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring Cincinnati D6, Edwards 2406 AB YEL / WHT GRND AC IN AC RTN BLK BLK VIO / WHT H M To Other Cloc ks PC 24-36VDC From Master Cloc k 115VAC Local Powe r Clock must be set within 20 m inutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is rec ommended t o avoid r[...]

  • Page 44

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 38 2-Wire Pulse Alternating (24VDC) A YEL / WHT GRND AC IN AC RTN BLK BLK VIO / WHT B To Other Cloc ks 24VDC From Master Cloc k H M 115VAC Local Powe r Clock must be set within 20 m inutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is rec ommended t o avoid r[...]

  • Page 45

    Page 39 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring Electronic Coded WHT Reciever 1 2 3 4 5 6 Clock will correct minutes hourly at HH:57 and hour and m inutes twice daily at 5:57. Requires 3510Hz receiver (not supplied) Set switches 1-5 of S1 as shown. Indicates depr essed side of s witch OPEN 7 8 BRN / WHT GRND AC IN A C RTN BLU / WHT B[...]

  • Page 46

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 40 Straight Frequency WHT Reciever 1 2 3 4 5 6 Clock will correct minutes hourly at HH:57 and hour and m inutes twice daily at 5:57. Requires 3510Hz receiver (not supplied) Set switches 1-5 of S1 as shown. Indicates depr essed side of s witch OPEN 7 8 BRN / WHT GRND AC IN A C RTN BLU / WHT[...]

  • Page 47

    Page 41 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring 3-Wire Minute Impulse (58 th Minute) B C 1 2 3 4 5 Clock must be set within 20 m inutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is rec ommended t o avoid resets after power failures. OPEN 6 7 8 Set switches 1-5 of S1 as shown. Indicates depr essed side [...]

  • Page 48

    DDC2 / 4-RS W iring Digital Display W all Clock Guid e Page 42 3-Wire Minute Impulse (44 th Minute) B C 1 2 3 4 5 Clock must be set within 20 m inutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is rec ommended t o avoid resets after power failures. OPEN 6 7 8 Set switches 1-5 of S1 as shown. Indicates depr essed side [...]

  • Page 49

    Page 43 Digital Display W all Clock Gu ide DDC2 / 4-RS W iring 2-Wire Reverse Polari ty Minute Impulse (59 th Minute) AB PC YEL / WHT GRND AC IN AC RTN BLK BLK VIO / WHT H M 24VDC From Master Cloc k 115VAC Local Powe r To Other Cloc ks Clock must be set within 20 m inutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is [...]

  • Page 50

    DDC2 / 4-RS -2 4 Wiring Digital Display W all Clock Guide Page 44 Appendix B - DDC2-RS-24 / DDC4 -RS-24 Wiring The DDC2-RS-24 and the DDC4-RS-24 allow for 24VAC supplied f rom the Master Clock or Power Supply to power it for normal operation. These models can be used in installations where local 115 VAC power m ay not be avai lable. Whe n shipped, [...]

  • Page 51

    Page 45 Digital Display W all Clock Gu ide DDC2 / 4-RS -24 Wiring DDC2-RS-24 / DDC4-RS-24 Wiring M BLU / WHT Run BRN / WHT BLK BLK H O P EN 1 2 3 4 5 6 7 8 Correction AC Return To Other Cloc ks Set switches 1-5 of S1 as shown. Indicates depr essed side of s witch 24VAC From Master Cloc k[...]

  • Page 52

    DDC2 / 4-RS -4 85 Wiring Digital Display W all Clock Guide Page 46 Appendix C - RS485 Wiring Diagrams RS485 Data Format The data string that sends the time to the DDC2 / DDC4 Series Wall Clocks is formatted in such a manner that a utility can be written to achieve tim e updates fr om a personal computer. The following table shows the layout and exp[...]

  • Page 53

    Page 47 Digital Display W all Clock Guid e DDC2 / 4-RS -485 Wiring OMCII to DDC2-RS / 4-RS Pin Signal Signal JP4 Connection 1 Transmit Data (-) Transmit Data (-) D- 2 Transmit Data (+ ) Transmit Data (+) D+ 8 Signal Ground Signal Ground GND To Other Cloc ks BLK BLK 115VAC Local Powe r OMCII DB 9 Femal e Plug Cable should be RS232 twisted pair / CAT[...]

  • Page 54

    DDC2 / 4-RS -4 85 Wiring Digital Display W all Clock Guide Page 48 LTR0 to DDC2-RS / 4-RS Wire Signal Signal JP4 Connection Gray Transmit Data (-) Transmit Data (-) D- Orange Transmit Data (+) Transmit Data (+) D+ Black Signal Ground Signal Ground GND 1 2 3 4 5 6 7 BLK BLK 115VAC Local Powe r To Other Cloc ks LTR0 Fly Leads LTR 0 BLK ORN GRY GND of[...]

  • Page 55

    Page 49 Digital Display W all Clock Guid e DDC2 / 4-RS -485 Wiring LTR4 / 8-512 to DDC2-RS / 4-RS Terminal # Signal Signal JP4 Connection 9 (D-) Transmit Data (-) Transmit Data (-) D- 8 (D+) Transmit Data (+) Transmit Data (+) D+ BLK BLK LTR4 / 8-512 Term inal Connections Cable should be RS232 twisted pair / CAT3 or CAT5 type. Maximum distance to l[...]

  • Page 56

    DDC-TC Timer Control Panel Digital Display Wall Clock Guide Page 50 Appendix D - DDC-TC Timer Control Panel Wiring The DDC-TC can be connected to the DDC Series Wall Clock wit h a 6 cond uctor CAT3 or CAT5 networ k cable. The DDC-TC can be mounted up t o 200 feet from the DDC Series Wall Clock. The DDC-TC comes with 6 wire nuts to connect the netwo[...]

  • Page 57

    Page 51 Digital Display Wall Clock Guide DDC-TC Timer Control Panel Installation The DDC-TC m ounts directly to a standard , double-gang wall box. (n ot included) Once the wirin g has been attached, place t he wires insid e the double- gang wall bo x and mount the DDC-TC to the box wi th the four screws supplied with the DDC-TC by inserting them th[...]

  • Page 58

    DDC-TC Timer Control Panel Digital Display Wall Clock Guide Page 52 Operation As a Count Up Timer To start the c ount: press Count Up To pause the c ount: press Stop / Continue To continue the count: press Stop / Continue To return to cl ock mode: press Quit As a Count Down Timer To set hours: press Set Hours (defualt is 00: ) To set minut es: pres[...]

  • Page 59

    Page 53 Digital Display W all Clock Guid e Specifications Appendix E - L TR-GPS Satellite Re ceiver / Clock Synchronizer Lathem’s LTR-GPS is a Global Positioni ng Satellite r eceiver using 12-channels to access the accurate date and time signal transm itted each second by 24 satellite s in geosynchronous orbit around the globe. The package includ[...]

  • Page 60

    Warranty Digital Display W all Clock Guide Page 54 The LTR-GPS package includes: LTR-GPS Satellite Synchronizer 115vAC, 2 . 7w, 50/6 0Hz Power Adapter Active GPS Antenna with 2 5ft. Cable Antenna M ounting B racket and Hardware Installation and Set-Up Guide Separately, from Lathem, for Installer convenience: GPS-INSTALL-T OOLS: Battery / Beeper ass[...]

  • Page 61

    Page 55 Digital Display W all Clock Guid e Specifications Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clock DDC2-R S / DDC4-R S[...]

  • Page 62

    Warranty Digital Display W all Clock Guide Page 56 Appendix F - S pecifications Dimensi ons DDC2 4 7/8" H X 10 1/4" W X 3 1/8" D 12.4 cm H X 26.2 cm W X 7.9 cm D DDC4 6 3/4" H X 15 1/2" W X 3 1/8" D 17.1 cm H X 39 cm W X 7.9 cm D Weight DDC2 3.2 lbs (1.4 51 kg) DDC4 9 lbs. (4.086 kg) Display DDC2 1 3/4-Inch Red 7 Segm [...]

  • Page 63

    Page 57 Digital Display W all Clock Guid e Specifications Appendix G - W arranty Limited One-Year Limited Warranty Lathem warrants the hard ware products descri bed in this guide against defects in material and workmanship for a period of one year from date of original purchase from Lathem or from an authorized Lathem reselle r. The conditions of t[...]