King Canada Mineral Hybrid manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of King Canada Mineral Hybrid, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of King Canada Mineral Hybrid one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of King Canada Mineral Hybrid. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of King Canada Mineral Hybrid should contain:
- informations concerning technical data of King Canada Mineral Hybrid
- name of the manufacturer and a year of construction of the King Canada Mineral Hybrid item
- rules of operation, control and maintenance of the King Canada Mineral Hybrid item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of King Canada Mineral Hybrid alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of King Canada Mineral Hybrid, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the King Canada service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of King Canada Mineral Hybrid.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the King Canada Mineral Hybrid item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    P ool F ROG Mineral HyBrid Operations Manual IMPORT ANT : This manual must be given to the homeowner to ensure warranty coverage. Customer Service 800-222-0169 www .kingtechnology .com[...]

  • Page 2

    When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: • It is recommended that a licensed electrician or certified electrical contractor perform the electrical connections. • DO NOT OPEN THE GENERATOR CONTROL PANEL – NOT A SERVICABLE UNIT. • READ AND FOLLOW ALL INST[...]

  • Page 3

    T ABLE OF CONTENTS 3 W arning-Safety First 2 Intr oduction 4 Star t-up 5 Adding Salt to the P ool 6 Inser ting POOL FR OG ® Mineral Reser v oir 7 Basic Operation 8 Contr ols 9 Easy Maintenance 10 POOL FR OG ® Mineral Hybrid Cell Cleaning 1 1 Winterizing 12 T r oubleshooting 13-15 Saturation Index 16 Glossary 17 POOL FR OG ® Mineral Hybrid Cyc le[...]

  • Page 4

    Par t 1 POOL FROG Mineral Hybrid Cycler The water treatment center that controls the flow of water through the system. Welcome to easier pool care courtesy of POOL FROG ® . With POOL FROG ® Mineral Hybrid, your pool water will look and feel better without a lot of work or a lot of chlorine. T his system controls bacteria using a combination of mi[...]

  • Page 5

    • Make sure the pool has adequate circulation. The pool water must completely circulate through the pump and filter at least 1 1/2 to 2 times per day . Check with your dealer for the proper circulation time for your pool. Star t-up WATER BALANCE GUIDELINES Minimum Ideal Maximum pH: 7.2 7.4 – 7.6 7.8 T otal Alkalinity: 60 ppm 80 – 100 ppm 120 [...]

  • Page 6

    Adding Salt to the Pool 6 5. ADDING THE SAL T A. Distribute the determined amount of salt evenly around the pool. To avoid clogging the filter or damaging the control panel and pump, do not add salt thr ough the skimmer or surge tank . Brushing the bottom helps dissolve the salt. B. Keep the pump on to circulate the water. C. The readout on the chl[...]

  • Page 7

    Inser ting POOL FROG ® Mineral Reser voir ( POOL FROG ® Mineral Reservoir s MUST be Replaced Ever y Season) SLO T IN POOL FROG ® MINERAL RESER V OIR FIN INSIDE OF POOL FROG ® CYCLER[...]

  • Page 8

    Basic Operation Periodically test your water and always maintain the following readings. (Use Saturation Index on page 16 to ensure proper balance.) Salt Level: 3000 - 4500 ppm Chlorine Level: 0.5 - 1.0 ppm pH: 7.2 - 7.8 IMPORT ANT : At least once a month have a professional test your water. Make sure there are no Nitrates or Phosphates in the wate[...]

  • Page 9

    CAUTION: Low Water Flow Power On/Off OUTPUT LEVEL 7 6 5 4 3 2 1 CAUTION: Salt Level High Set dial to achieve desired output level. IMPORTANT: Fine tuning is possible without indicator lights changing. See side panel or manual for additional directions. 9 Contr ols 1. OUTPUT LEVEL — The lights marked 1-7 indicate the system’s chlorine output. Th[...]

  • Page 10

    Easy Maintenance Replacing the Contr ol Dial O-Rings Kit Replacing Cap O-Ring • Hold cap in front of you upside down with the o-ring groove facing up. Place one end of o-ring into cap groove at the point closest to you. Hold o-ring down with the thumb and forefinger of one hand. • T ake hold of the far end of the o-ring with the thumb and index[...]

  • Page 11

    Cleaning POOL FROG ® Mineral Hybrid Cell 11 CELL WIRING DIAGRAM Our clear cell allows for easy regular inspections for calcium build up. Visually check the cell periodically, and clean it as necessary (1 to 2 times per year). Advanced self-cleaning with shake plates helps the cell stay cleaner than other self-cleaning cells, but minimal biannual c[...]

  • Page 12

    Winterizing • T urn pump off and turn dial to 0. • Remove cap. • Unscrew knob in the back of POOL FROG ® Mineral Hybrid Cycler . Allow all water to drain. • Remove the POOL FROG ® Mineral Reservoir and discard in trash. Even if you hear spent minerals inside, it is no longer effective. Replace with a new POOL FROG ® Mineral Reservoir in [...]

  • Page 13

    Insufficient water flow from pump This is normal for a few minutes at initial to flow sensor and cell. startup or if air is in the lines. Clean filters and strainers. Check for closed valves, faulty pump, etc. 4. CAUTION: Low Flow Light Obstruction or scale buildup in cell. Clean cell according to instructions on page 11. is Solid Red Flow sensor w[...]

  • Page 14

    B. Red caution light is solid or Salt level is very high. The generator could Drain part of the water and refill the pool. output lights 1-7 go up completely turn off and no longer produce It is also recommended to periodically test and down quickly. chlorine until the situation is rectified. the salt level by a professional. If above 5500 ppm, che[...]

  • Page 15

    Have your water tested for chlorine levels, pH, phosphates and nitrates. 12. Algae May be due to low chlorine levels Use a nonmetallic (polyquat) algaecide per or a chemical imbalance. the directions on the bottle and brush the sides of the pool often. Clean the filter and shock the pool with chlorine daily until water clarity returns. See “Chlor[...]

  • Page 16

    Saturation Index 16 Test the water for pH, Alkalinity, Calcium Hardness and Temperature, then follow the simple steps below: 1. Write your pool’s pH level here: pH: ________ 2. Find your Alkalinity level in the chart below, and write the corresponding Alkalinity Factor here: Alkalinity Factor: ________ Pool Alkalinity 5 25 50 75 100 150 200 300 4[...]

  • Page 17

    Glossary 17 Salt: To ensure maximum benefits with the use of the system, the ideal salt level is 4000 ppm (parts per million). A low concentration of salt can hinder the generator’s effectiveness. A concentration of salt above 5500 ppm may cause corrosion damage to the pool fixtures. See Adding Salt on page 6. Total Dissolved Solids (TDS) are dif[...]

  • Page 18

    POOL FROG ® Mineral Hybrid Cycler Parts List DIAGRAM/P ARTS LIST REF . # P ART No. DESCRIPTION QTY . REQ. 1 & 2 01-22-9412 Cap w/O-Ring 1 2 01-22-9920 Cap O-Ring 1 3 N/A Body 1 4 01-22-9480 Pressure Relief V alve 1 5, 6, 7 01-22-9440 Control Dial with Assembly Kit 1 6 & 7 01-22-9450 Control Dial O-Ring Kit 1 8 & 9 01-22-9940 Knob with [...]

  • Page 19

    19 King T echnology , Inc. w arrants to the original purchaser this unit will be free from any def ects in workmanship and/or material, for a period of two (2) years from the date of original purchase. This w arranty cov ers body , cap and control dial, but specifically e xcludes o-r ings. King T echnology at its option may replace an y def ective [...]

  • Page 20

    Manufactured b y: KING TECHNOLOGY , INC. 530 11th A venue South, Hopkins, MN 55343 U .S.A. 952-933-6118 . 800-222-0169 . F AX 952-933-2206 www.kingtechnology.com Assembled from components made in the U.S.A. and Israel. Covered by one or more of the following U.S. Patent Numbers: 4,662,387; 5,076,315; 5,218,983; 6,190,547; 6,210,566; 6,217,892; 6,38[...]