Kathrein VGO 939-1G/VGF 939-1G manual

1
2
3
4
5
6
7
8
9
10
11

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Kathrein VGO 939-1G/VGF 939-1G, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Kathrein VGO 939-1G/VGF 939-1G one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Kathrein VGO 939-1G/VGF 939-1G. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Kathrein VGO 939-1G/VGF 939-1G should contain:
- informations concerning technical data of Kathrein VGO 939-1G/VGF 939-1G
- name of the manufacturer and a year of construction of the Kathrein VGO 939-1G/VGF 939-1G item
- rules of operation, control and maintenance of the Kathrein VGO 939-1G/VGF 939-1G item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Kathrein VGO 939-1G/VGF 939-1G alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Kathrein VGO 939-1G/VGF 939-1G, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Kathrein service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Kathrein VGO 939-1G/VGF 939-1G.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Kathrein VGO 939-1G/VGF 939-1G item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Antennen · Electr onic Compact amplifier s VGP 9033-1G/9041 VGF 9030/9040 VGO 939-1G/VGF 939-1G VOS 952-1G/953-1G[...]

  • Page 2

    3 "Plug-and-Play" r edefined Ele ctronic setting of all important parameters, automatic levelling (only for VGP 9033-1G/9041) as well as remote configuration via HMS or DOCSIS monitoring ensure the shortest start-up and maintenance times. The copy function enables one to copy all settings and transfer them to another device at the press[...]

  • Page 3

    DET AILS, ACCESSORIES, BLOCK DIAGRAM, DELIVER Y ST A TUS 4 Delivery status F-type test socket internal (-20 dB) F-type test socket internal (-20 dB) Output insert position Insert position "Forward 1" e.g. for additional C-line pre-emphasis Connection socket for hand-held unit HTE 10 Insert position for monitoring transponder (not included[...]

  • Page 4

    6 7 T echnical Data DESCRIPTION VGO 939-1G/ VGF 939-1G DA T A T ype VGF 9030 VGF 9040 VGP 9033-1G VGP 9041 Order no. 24410108 24410109 24410103 24410054 FORW ARD P A TH Frequency range MHz 85-862 85-862 85-1000 85-862 Gain (at 1000 MHz) dB 33 40 33 40 Return loss dB 19-1.5 dB/oct. Frequency r esponse (85-1000 MHz at 25 °C) dB ± 0.5 Max. output le[...]

  • Page 5

    Attenuation or pre-emphasis Current T emperature Ub ICS Monitoring transponder 2 / 0 / 4 dB 2 / 0 / 4 dB 6 / 0 / 12 dB 6 / 0 / 12 dB 5 - 65 MHz 85 - 1006 MHz 85 - 1006 MHz 5 - 65 MHz 4 / 0 / 8 dB T est 3 -10 dB 4 / 0 / 8 dB 0 / -8 dB / "switched-off" Interstage Pre-emphasis Pre-emphasis dB Pre-emphasis 5-65 MHz Internal Attenuation Attenu[...]

  • Page 6

    1 1 T echnical Data DESCRIPTION VOS 952-1G/953-1G DA T A T ype VGO 939-1G VGF 939-1G Notes Order no. 24410101 24410100 Locally fed Remotely fed FORW ARD P A TH Frequency range MHz 85-1000 Gain dB 40 Gain setting range, interstage ³ ) dB 32-40 Amplitude response dB ±0.5 85-1000 MHz, at 25 °C Amplitude response (additional, 862-1000 MHz) dB -0.5 a[...]

  • Page 7

    1 2 DET AILS, ACCESSORIES, BLOCK DIAGRAM, DELIVER Y ST A TUS Accessories Delivery status 1 3 LED (Power supply function) ) Input insert position e.g. for de-emphasis equaliser Insert position for monitoring transponder (not included in delivery scope) F-type test socket for the return path (-10 dB) F-type test socket bidirectional on input (-20 dB)[...]

  • Page 8

    1 4 1 5 DA T A T echnical Data 1) Adjustable with 2 slide switches in 1 dB steps 2) CENELEC: 42 channels 3) When the 15 MHz high pass is connected, the dynamic range increases by 3 dB T ype VOS 952-1G VOS 953-1G Notes Order no. 24410098 24410099 Locally fed Remotely fed FORW ARD P A TH Frequency range MHz 47/85-1000 47/85-1000 Gain ¹) dB 40-32 40-[...]

  • Page 9

    1 6 1 7 HTE 10 - Hand-held unit With the HTE 10 hand-held unit one is able to adjust correspondingly equipped devices on site. Using the 'Up' and 'Down', 'Menu' and 'Enter' buttons, one is able to change and set the values on the 4-line display . The display is illuminated and easy to read. Accessories Monito[...]

  • Page 10

    EAC 90-1G, 93-1G, 94-1G – T ap-of f cards 1 8 1 9 T ype EAC 90-1G EAC 93-1G EAC 94-1G EBC 90 -1G Order no. 24510116 24510115 24510114 24510113 Frequency range MHz 5-1000 5-1000 5-1000 5-1000 Through loss ¹) 5- 610 MHz dB < 1.3 < 2.1 < 0.5 < 3.6 Through loss ¹) 61 0-8 62 MHz dB < 1.3 < 2.3 < 0.6 < 3.8 Through loss ¹) 86 [...]

  • Page 11

    W e are pleased to advise you: 99811514/1/0810/JH/Pf T echnical data subject to modification. T echnical data repr esent typical values. Antennen · Electr onic The pr oducts described must only be installed by qualified specialists. Please consult the provided instruction manuals for the safety instructions that are to be considered during use. KA[...]