The rules should oblige the seller to give the purchaser an operating instrucion of Karcher 600 LP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Karcher 600 LP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Karcher 600 LP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Karcher 600 LP should contain:
- informations concerning technical data of Karcher 600 LP
- name of the manufacturer and a year of construction of the Karcher 600 LP item
- rules of operation, control and maintenance of the Karcher 600 LP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Karcher 600 LP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Karcher 600 LP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Karcher service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Karcher 600 LP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Karcher 600 LP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    BTA 5.960-505 .0 ETL 5.970-054.0 (LP 400V) 5.970-055.0 (MP 400V) 5.970-156.0 (LP 230V) 5.970-157.0 (MP 230V) A 2011201 Operating Instructions WATERCLEAN 600 LP / MP[...]

  • Page 2

    WTC 600 LP / MP 2 Version 06/05 1 2 3 4 6 7 18 19 8 9 20 10 13 14 17 16 12 11 15 5[...]

  • Page 3

    WTC 600 LP / MP 3 Safety Notes Version 06/05 Contents Equipment Components 1 Sand filte r 2 Activated carbon filter 3 Control, activated carbon filter 4 Control, sand filter 5 Manometer, sand filter supp ly pressure 6 Manometer, acti vated carbon filt er supply pressure 7 RO filter unit 8 Switch box 9 Operating mode switch 10 Control panel 11 Manom[...]

  • Page 4

    WTC 600 LP / MP 4 Maintenance and Care Version 06/05 3 Maintenance and Care 3.1 Starting Operation Before starting operation : • Make sure that the equipment is conne cted to the untreated wa ter source and the respective transporting ge ar, e. g., admission-pressure unit. • Ensure the unrestrict ed flow of the drink ing water into a tank or a [...]

  • Page 5

    WTC 600 LP / MP 5 Maintenance and Care Version 06/05 3.1.3 Switching On the Equipmen t • Check if the pumps of the metering station, sand and activat ed carbon filter are co nnected to the respective power out lets (18 / 19) at the switch b ox (8). • Check if the operati ng mode switch (9) is in the correct position “Automatic” or “Hand?[...]

  • Page 6

    WTC 600 LP / MP 6 Maintenance and Care Version 06/05 3.2 During Operation 3.2.1 Control and Correct ive Action Intervals d…daily, w…weekly, m… mont hly 3.2.2 Sand and Activat ed Carbon Fi lter During operation, th e sand and activated carbon filter control indi cates the actual time. To cha nge the indicati on: • Press button (32) for appro[...]

  • Page 7

    WTC 600 LP / MP 7 Maintenance and Care Version 06/05 • After a while the indication moves ba ck to the current tim e. 3.2.3 Bleeding th e Metering Pump The meter ing pump m ust be bled when the pump has drawn in air (e. g., because the metering con- tainer is comple tely em pty). • The system stops; the “Motor / hard water“ mal- function in[...]

  • Page 8

    WTC 600 LP / MP 8 Maintenance and Care Version 06/05 • Before screwing on the fil ter bowl, check t he sealing ring (39) for da mage. • Screw on the filter bowl an d tighten with the fil- ter wrench. • Open the untreated water supply again and start the system with th e main swit ch. 3.2.5 Fine Adjustment of the Operating Pressures (1) Flo w [...]

  • Page 9

    WTC 600 LP / MP 9 Maintenance and Care Version 06/05 Notice: The amount of concentrate will in- crease. This is correct. Observe the maximum pressure of 21 bar (MP) or 14 bar (LP) at the manometer (11)! • Repeat the adjustment steps, if req uired. The original dr inking water amount may possibly not quite be reached. (3) The difference between pu[...]

  • Page 10

    WTC 600 LP / MP 10 Consumption Material s Version 06/05 (2) Metered Addition The metered addit ion is carried out dependent of the level in the meterin g container. Complete ly emptied m etering conta iner: • Fill 10 l of drinking water into the metering con- tainer. • With a measuring cup, measure the 7.5 -fold amount mentioned in the “10 Li[...]

  • Page 11

    WTC 600 LP / MP 11 Malfunctions Version 06/05 5 Malfunctions Malfunctions o f the RO system are signal ed with LEDs at the control pane l (10) and indicated at the display. Malfunctions on the admission-pre ssure unit are indicated wit h the red LED (26) on t he control unit of the admission-pressu re unit. i In case of a malfunc tion, the system i[...]

  • Page 12

    WTC 600 LP / MP 12 Technical Data Version 06/05 6 Technical Data Parameter WTC 600 LP WTC 600 MP Ambient temperature +1 °C – +50 °C Storage temperature (upon delivery) to –10 °C Humidity <100 % r.F. Supply voltage 3*400 V 50 Hz * 1*230 V 50 Hz * * depending on supply by the customer Pre-filter controls: pr im. / sec. 230 V/12 V 50 Hz Mete[...]

  • Page 13

    WTC 600 LP / MP 13 EU Declaration of Confo rmity Version 06/05 7 EU Declaration of Conformity We hereby declare that the equipment described below conforms to the rele vant fundamental safety an d health requirements of the appropriat e EU Directive, both in its basi c design and const ruction as well as in the version marketed by us. This declarat[...]