JVC LYT1053-001B manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of JVC LYT1053-001B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of JVC LYT1053-001B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of JVC LYT1053-001B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of JVC LYT1053-001B should contain:
- informations concerning technical data of JVC LYT1053-001B
- name of the manufacturer and a year of construction of the JVC LYT1053-001B item
- rules of operation, control and maintenance of the JVC LYT1053-001B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of JVC LYT1053-001B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of JVC LYT1053-001B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the JVC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of JVC LYT1053-001B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the JVC LYT1053-001B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Instructions MICRO HD CAMERA DZ-VCA3U LYT1053-001B Serial No. Model No.[...]

  • Page 2

    2 Feature Contents Applications .......................................................................... 3 Precautions on installing medical electrical equipment (Safety and hazar d prevention) ........................................ 3 Safety precautions ............................................................... 4 Important product safety i[...]

  • Page 3

    3 Applications Micro HD camera system can be used f or follo wing application; Endoscope operation in OR. (This system should only be operated b y doctors or authorized persons.) Abov e application, the system can supply HD and SD signals to HD/SD monitor f or display and to HD/SD VTR f or recording/pla yback. F or the safe use of this equipment, a[...]

  • Page 4

    4 Safety precautions Please Read Bef ore Use W ARNING: This MICR O HD CAMERA should be used with a power suppl y of AC 120 V , 60 Hz only . To prevent electric shoc ks and fire hazar ds, DO NO T use an y other po wer supply . W ARNING: This camera head with camera cable and camera contr ol unit are not sterilized. Bef ore using, please conduct the [...]

  • Page 5

    5 Impor tant pr oduct saf ety instructions PORTABLE CART WARNING (Symbol provided by RETAC) INST ALLA TION AND DISPOSAL 1. Grounding or P olarization Precautions should be taken so that the g rounding or polarization of an appliance is not defeated. 2. P ower Sources Operate y our product only from the type of power source indicated on the marking [...]

  • Page 6

    6 SER VICING 1. Servicing Should the product f ail to work nor mally , do not attempt to fix it yourself . Please rely on a qualified ser vice person. Note: Bef ore returning the camera head, endoscope adapter , be sure to sterilize the camera head with cable and endoscope . 2. Damage Requiring Service Unplug this product from the wall outlet and r[...]

  • Page 7

    7 If a prob lem develops concerning the opera- tion of this pr oduct while it is being employed as an endoscopy system during sur gery , etc., take the appropriate action as described below: L Problem with the endoscope The lamp f or the light source ma y hav e been bur ned out. Please read the operating manual f or details on replacing the lamp . [...]

  • Page 8

    8 Phenomena peculiar to CCDs Monitor screen Pale, vertical streaks appear in the picture. High-intensity subject (electric light, lamp, the sunlight, etc.) The f ollowing CCD-related phenomena ma y appear on the view screen during shooting. These are caused by the CCD and are not malfunctions . Smear Phenomenon Occurs when a luminescent subject is [...]

  • Page 9

    9 Connections Notes: • Use the abov e composition of device or its equiv alent. • Do not connect this camera to equipment other than that depicted in these connection diag rams. • When connecting monitors, VTR, etc to the camera control unit, please rely on a qualified serviceman to check that the increased current leakage does not surpass th[...]

  • Page 10

    10 Name of par ts and their functions Camera control unit (fr ont panel) 1 [PO WER] power s witch and power indication LED When s witching power on again after it is just s witched off: W ait for more than 5 seconds bef ore switching it on. 2 [CAMERA] camera cable connector Connect to camera head. 3 [OUTPUT LEVEL] output level contr oller section S[...]

  • Page 11

    11 Camera control unit (rear panel) 1 Lens mount ring Standard C mount is used. Flange back will be 17.526mm in air . 2 Camera cable connector (plug) Connect to camera control unit. Camera head ~AC IN NTSC OUT SXGA OUT GBR DV Y PB PR Y/C (S) VBS HD OUT GENLOCK IN/OUT 6 7 5 3 1 2 4 2 1 [A C INPUT] power input connector To input AC120V . 2 Equal-pote[...]

  • Page 12

    12 Names of par ts and their functions (continued) Output level contr ol section 4 SHUTTER UP/SHUTTER DO WN button Using the [SHUTTER UP] / [SHUTTER DO WN] button, the f ollowing setting is possib le: 1/60, 1/100, 1/175, 1/250, 1/375, 1/500, 1/1000, 1/2000, 1/4000, 1/10000. Enabled only when [GAIN] s witch 1 is set to [MANU AL]. • When looking at[...]

  • Page 13

    13 White balance control section ON I O OFF POWER CAMERA SETTING RED BLUE WHITE BALANCE AUTO M ANUAL ON OFF ENHANCE FREEZE BAR MENU SETTING GAIN SHUTTER OUTPUT LEVEL ADJUST AUTO M ANUAL SETTING RED BLUE WHITE BALANCE AU TO MANUAL 7 5 6 5 WHITE B ALANCE switch 6 SETTING button 7 R/B button [A UT O] When set to this position, the camera is automatica[...]

  • Page 14

    14 Names of par ts and their functions (continued) Mode control section Menu contr ol section 8 ENHANCE button To set enhance. By pressing this button, LED will light up , and the enhance will be functional. Press it again, then LED will light off and the emphasis will disappear . 9 FREEZE b utton By pressing this button, LED will light up , and fr[...]

  • Page 15

    15 IN D I C A T IO N 1 IN D I C A T IO N 2 IN D I C A T IO N 3 ID / C O D E GA I N& S H U T OF F ID / C O D E . DA T E SY N C &T I M E [INDICA TION1] menu Set the displa y on the top left of HD OUT and SXGA OUT screen. Selection items and functions are as f ollows: Selection items Functions ID/CODE Displa ys the content set under ID/CODE me[...]

  • Page 16

    16 Names of par ts and their functions (continued) [ID/CODE] menu Edit ID/CODE that can be displa yed on the screen. • Select from INDICA TION 1, 3 menu to see if it can be display ed. • Message is up to 22 alphanumeric characters. • Characters that can be used: A-Z, 0-9, ., :, -, /, and space. [D A TE&TIME] menu To change date and time s[...]

  • Page 17

    17 Basic operation White balance adjustment a AU TO SETTING RED BLUE WHITE BALANCE AU TO MANUAL SETTING RED BLUE WHITE BALANCE AU TO MANUAL SETTING button WHITE BALANCE s witch R/B volume control WHITE BALANCE s witch a MANU AL Connect a measur ing instrument such as a wav eform monitor to the HD output jack, and adjust the white balance while w at[...]

  • Page 18

    18 System operation AC 120V Connector Connector Cap Mark (Red) Camera head CCU Camera control unit DZ-VCA3U SR-W7MAU (W-VHS) (Optional) DT-V1900CG (Optional) Isolation transformer AA-V31U (Optional) ON I O OFF POWER CAMERA SETTING RED BLUE WHITE BALANCE AU TO MANUAL ON OFF ENHANCE FREEZE BAR MENU SETTING GAIN SHUTTER OUTPUT LEVEL ADJUST AU TO MANUA[...]

  • Page 19

    19 Connector a Camera cable connector input/output terminals (CCU side) 10 16 13 11 12 1 15 2 3 14 4 17 5 6 7 19 8 9 18 Attention, consult ACCOMPANYING DOCUMENTS Alternating current Off (power: disconnection from the mains) On (power: connection to the mains) Protective earth (ground) Earth (ground) TYPE OF APPLIED CF EQUIPMENT Equipotentiality Vid[...]

  • Page 20

    20 Design and specifications subject to change without notice. MICRO HD CAMERA DZ-VCA3U Camera head section L Image sensing device : 1/3-inch PS-CCD (350,000 pix els) L Shooting system : 3-CCD system L Color separation optical system : 1/3-inch F1.4 3-color separation prism L Number of effective pixels : 659 (horizontal) x 494 (v er tical), 330,000[...]

  • Page 21

    21 L Outer dimensions Camera head 27.4 44 57.2 57.7 43 12.7 51.4 1.5 (Top) (Rear) (Side) (Front) (Bottom) (Side) (Front) (Rear) ~AC IN NTSC OUT SXGA OUT GBR DV Y PB PR Y/C (S) VBS HD OUT GENLOCK IN/OUT ON I O OFF POWER CAMERA SETTING RED BLUE WHITE BALANCE AU TO MANUAL ON OFF ENHANCE FREEZE B AR MENU SETTING GAIN SHUTTER OUTPUT LEVEL ADJUST AU TO M[...]

  • Page 22

    22 Optional Equipments Isolation transformer AA-V31U L Input : 120 V AC 3.1 A 60 Hz L Output : 120 V AC 3.0 A 60 Hz L We ight : 6.7kg L Accessories : Plug retainer brack et x 3 T orx head screw x 8 Cov er plate x 3 Flat washer x 3 Split locking w asher x 3 HD monitor DT -V1900CG L Po w er requirements : 120 V AC 60 Hz L Po w er consumption : 1.6 A [...]

  • Page 23

    23 W arranty record confirmation and safekeeping This product is sold with a warranty card attached. W arranty card has been delivered to sales dealer of this product. Please check y our par ticulars and the record after filling, and keep it properly . L W arranty period: W arranty per iod is one year from the date of purchase . Thereafter , ser vi[...]

  • Page 24

    DZ-VCA3U COPYRIGHT 2002 VICTOR COMPANY OF JAPAN, LTD. U Printed in Japan VICTOR COMP ANY OF JAPAN, LIMITED 0902-MN-SW-SW[...]