Johnson Controls 356486-UUM-E-0109 manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Johnson Controls 356486-UUM-E-0109, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Johnson Controls 356486-UUM-E-0109 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Johnson Controls 356486-UUM-E-0109. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Johnson Controls 356486-UUM-E-0109 should contain:
- informations concerning technical data of Johnson Controls 356486-UUM-E-0109
- name of the manufacturer and a year of construction of the Johnson Controls 356486-UUM-E-0109 item
- rules of operation, control and maintenance of the Johnson Controls 356486-UUM-E-0109 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Johnson Controls 356486-UUM-E-0109 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Johnson Controls 356486-UUM-E-0109, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Johnson Controls service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Johnson Controls 356486-UUM-E-0109.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Johnson Controls 356486-UUM-E-0109 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    356486-UUM-E-0109 USER’S INFORMA TION MANU AL MODELS: All Residential Multi- position Gas Furnaces (33” Models) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System We recommend that the user read all sections of this manual and keep the manu al for future reference. SECTION I: SAFETY This is a safety alert symbol . When you[...]

  • Page 2

    356486-UUM-E-0109 2 Johnson Controls Unitary Products SECTION II: INSTRUCTIONS FOR EXAMINING THE FURNA CE INST ALLA TION It is the owner ’s responsibility to ensure that an annual inspection of the entire heating portion of the unit is made by a qualified service agency . Examine the furnace as outlined below in steps “1 - 8” before each heat[...]

  • Page 3

    356486-UUM-E-0109 Johnson Controls Unitary Products 3 1. Examine the heat exchanger , vent pipe, combustion air passages, vent connectors and chimney to be sure they are clear and free of obstructions. 2. Examine the vent pipe making sure it is firmly in place, that it slopes slightly upward and is phy sically sound without holes and all of the con[...]

  • Page 4

    356486-UUM-E-0109 4 Johnson Controls Unitary Products OPERA TING INSTRUCTIONS 1. STOP! Read the safety inform ation above for your protection. 2. Set the thermostat to the lowest setting in the heat mode. 3. T urn off all electric power to the appliance. 4. Remove furnace burner access panel/door . 5. Move gas control switch to the “OFF” positi[...]

  • Page 5

    356486-UUM-E-0109 Johnson Controls Unitary Products 5 Every time the external air filters are changed the following items should be visually inspected: • Check combustion air and vent pipe for blockage or leakage. • Check all components to be sure they are in good condition and that there are no obvious signs of deterioration. • Check the dra[...]

  • Page 6

    Subject to change without notice. Printed in U.S.A. 356486-UUM-E-0109 Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 356486-UUM-D-1108 Johnson Co ntro ls Unit ary Product s 5005 Y ork Drive Norman, OK 73069 Limited Warranty UPG warrant s this produc t to be free from defec ts in factory wo rkmanship and ma terial under[...]