Intel MPRTM4808 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Intel MPRTM4808, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Intel MPRTM4808 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Intel MPRTM4808. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Intel MPRTM4808 should contain:
- informations concerning technical data of Intel MPRTM4808
- name of the manufacturer and a year of construction of the Intel MPRTM4808 item
- rules of operation, control and maintenance of the Intel MPRTM4808 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Intel MPRTM4808 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Intel MPRTM4808, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Intel service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Intel MPRTM4808.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Intel MPRTM4808 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Order Number: 301370-002 Intel ® NetS tructure™ MPRTM4808 Rear T ransition Board Installation Guide December 2004[...]

  • Page 2

    2I n t e l ® NetStructure ™ MPRTM480 8 Rear Transit ion Board Installation Guide INFORMA TION IN THIS DOCUMENT IS PRO VIDED IN CONNEC TION WITH INTE LR PRODUCTS. E XCEPT AS PROVIDED IN INTEL ’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LI ABILITY WHA TSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELA TING [...]

  • Page 3

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 3 Contents Contents 1 Using This Guide ................. ............. ................ ................ ............. ................ ................ ... ............... 6 1.1 Terms and Definitions .................. ................ ................ ................[...]

  • Page 4

    4I n t e l ® NetStructure ™ MPRTM480 8 Rear Transit ion Board Installation Guide Contents 5 Warranty Information ....... ................ ................ ................. ............. ................ ................ ..... ........... 30 5.1 Intel ® NetStructure™ Compute Boards & Platfo rm Products Limited Warranty ....... .......... [...]

  • Page 5

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 5 Contents Revision History Date Revision Description May 2004 001 Initial release of this manual December 2004 002 Modified Serial Connectors information[...]

  • Page 6

    6I n t e l ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Using This Guide Using This Guide 1 The Intel ® NetStructure™ MPR TM4808 Rear Transition Board Installation Guide i s intended for users qualified in electronics or electrical engineering. Users shou ld have a w orking understanding of PCI, CompactCPCI, an d telecom[...]

  • Page 7

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 7 Operating Sa fety Operating Safety 2 This section provides safety precau tions to follow when installing, operating, and maintaining the Intel ® NetStructure™ MPR TM4808 Rear Transition Board. Intel intends to provide all n ecessary information to install and handl[...]

  • Page 8

    8I n t e l ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Operating Safety 2.3 Inst allation Electrostatic dischar ge and incorr ect bo ard installation and rem oval can damage circuits o r shorten their life. Therefore: • Make sure that you are working in an ESD- safe environment before touchi ng boards or electronic compo[...]

  • Page 9

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 9 Operating Sa fety 2.6 RJ-45 Connector The Intel MPR T M4808 board provides several RJ-45 connectors that commonly serve as different interfaces (RS-485, twisted-pair Ethernet, and te lephone). Connecting diff erent interfaces (e.g., Ethernet and RS-485) may damage the[...]

  • Page 10

    10 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Installation Installation 3 3.1 Introduction The Intel ® NetStructure™ MPR TM4808 Rear T ransition Board provides easy access to I/O signals of boards via the CompactPCI backplane. Backplane I/O signals are available at connector J5. T o connect System Management Bus [...]

  • Page 11

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 11 Installation 3.2 St andard Compliances The Intel MPR TM4808 board meets th e following standards: 3.3 On-Board Connectors The Intel MPR TM4808 board provid es the following on-board connectors: T able 2. St andard Compliances St andard D escription EN 60950 UL/cUL 19[...]

  • Page 12

    12 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Installation 3.3.1 Secondary EIDE Interface The Intel MPR TM4808 board provides the secondary EIDE interface via CompactPC I connector J5. The secondary EIDE in terface can be used for: • One EIDE device • T wo EIDE devices • One EIDE device and one CompactFlash di[...]

  • Page 13

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 13 Installation Note: CompactFlash disks of types I and II are supported. 3.3.1.3 Inst allation Procedure Note: T o configure the card to the supported true-IDE mo de, the card must alread y be inserted when the board’ s power is turned on. Inserting the CompactFlash [...]

  • Page 14

    14 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Installation 3.3.1.4 Removal Procedure 1. T urn off CPU power . 2. Press ejector pin. The ejector pin loosens the CompactFlash disk from the socket. 3. Remove CompactFlash disk from In tel MPR TM4808 board. 4. T urn on CPU power . 3.3.2 Floppy Disk Drive Note: The board [...]

  • Page 15

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 15 Installation 3.3.4 PMC I/O Signals The I/O signals of PMC Sl ots 1 and 2 of the CP U board are routed to tw o 64-pin connectors. Figure 8 and Figure 9 show the pinouts. Figure 8. PMC 1 Connector Pinout[...]

  • Page 16

    16 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Installation Figure 9. PMC 2 Connector Pinout[...]

  • Page 17

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 17 Installation 3.4 Switch Settings Caution: The Intel MPR TM4808 board provid es two on-board switches and one FP reset switch. The switches must be set to OFF to avoid damage to attached PMC modules. 3.5 Inst alling and Removing the Board Caution: • T o prevent boar[...]

  • Page 18

    18 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Installation • Before touching integrated circu its, make sure that you are working in an ESD-safe environment. • When plugging the board in or removing it, use the handles; do not press on the front panel. 3.5.1 Inst allation Procedure Note: Connect interface cables[...]

  • Page 19

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 19 Installation 3.5.2 Removal Procedure 1. Check all installed boards for steps to perform before turn ing off power . 2. T urn off system power . 3. Unfasten screws of front panel until Intel MP R TM4808 board is detached from rack frame. 4. Unlock handles by pressing [...]

  • Page 20

    20 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Installation Figure 13. J3 Connector Pinout (Rows D and E) Figure 14. J5 Connector Pinout (Rows A-C)[...]

  • Page 21

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 21 Installation Figure 15. J5 Connector Pinout (Rows D and E)[...]

  • Page 22

    22 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Installation 3.7 Front Panel Connectors and Controls The Intel MPR TM4808 board front panel provides the follow ing connectors and controls: Caution: The Intel MPR TM4808 board provides several RJ-45 connectors that commonl y serve as different interfaces (RS-485, twiste[...]

  • Page 23

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 23 Installation 3.7.1 ICMB Connector The ICMB connector can be used to attach the Intel NetStructure MPCBL5525 System Master Board via the Int el MPR TM480 8 board to other syst ems based on the IPM I. T o monitor the o verall system, the chassis can be connected via th[...]

  • Page 24

    24 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Installation 3.7.3 Serial Connectors T wo serial devices can be connected via the tw o COM connectors, and one USB device (e.g., USB keyboard, USB mouse) can be connected via the USB connector . Note: The two COM ports are only available if the Intel MPR TM4808 board i s[...]

  • Page 25

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 25 Installation The translation between the DB-9 and RJ-45 conn ectors is llustrated in the following diagram: 3.7.4 Reset Key The Intel MPR TM4808 bo ard provides a reset key on the front panel to execut e a reset on the Intel NetStructure MPCBL5525 Sys tem Ma ster Boa[...]

  • Page 26

    26 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Agency Approvals Agency Approvals 4 4.1 CE Certification The Intel ® NetStructure™ MPR TM4808 Rear Transition Board meets intent of Directive 89/336/ EEC for Electromagnetic Compatibility and Low -V oltage Directive 73/23/EEC for Product Safety . The Intel MPR TM4808 [...]

  • Page 27

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 27 Agency Approvals 4.3.2 EN 55024 Immunity GR-1089-CORE Sections 2 and 3 EN 61000 4-2 Electro-Static Discharge (ESD) EN 61000 4-3 Radiated Susceptibilit y EN 61000 4-4 Electrical Fast T ransient Burst EN 61000 4 -5 Power Line Surge EN 61000 4-6 Frequency Magnetic Field[...]

  • Page 28

    28 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Agency Approvals 4.5 Product Safety Information 4.5.1 Safety Precautions Review the following precautions to avoid injury and prevent dama ge to this product, or any products to which it is connected . T o avoid potential hazards, use the product only as specified. Read [...]

  • Page 29

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 29 Agency Approvals 4.6 AC and/or DC Power Safety W arning (AC and/or DC Powered Unit s) The AC and/or DC power cord is you r unit's main AC and/or DC disconnecting device, and must be easily accessible at all times. Au xiliary AC and/or DC On/Off sw itches and/or [...]

  • Page 30

    30 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Warranty Information W arranty Information 5 5.1 Intel ® NetS tructure™ Compute Boards & Platform Product s Limited W arranty Intel warrants to the original owner that the product deli vered in this package will be free from defects in material and workmanship for[...]

  • Page 31

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 31 Warranty Information 5.1.1.1 For the Americas Return Material Authorization (RMA) credi t re quests e-mail address: requests.rma@intel.com Direct Return Auth orization (DRA) repai r requ ests e-mail address: uspss.repair@intel.com DRA on-line form: htt p://support.in[...]

  • Page 32

    32 Intel ® NetStructure™ MPRTM4808 Rear Transition Board Installation Guide Warranty Information If the Customer Support Group veri fies that the product is defective, they w ill have the Direct Return Authorization/Retu rn Material Authorization Department issue yo u a DRA/RMA number to place on the outer package of the pro duct. Intel cannot a[...]

  • Page 33

    Intel ® NetStructur e™ MPRTM4 808 Rear T ransition Boar d Installation Guide 33 Customer Support Customer Support 6 This section offers technical and sales assistan ce information for this product, and info rmation on returning an Intel ® NetStructure™ product for service. 6.1 T echnical Support and Return for Service Assist ance For all prod[...]