Intel L440GX manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Intel L440GX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Intel L440GX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Intel L440GX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Intel L440GX should contain:
- informations concerning technical data of Intel L440GX
- name of the manufacturer and a year of construction of the Intel L440GX item
- rules of operation, control and maintenance of the Intel L440GX item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Intel L440GX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Intel L440GX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Intel service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Intel L440GX.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Intel L440GX item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    L440GX+ Server Board Product Guide Order Number: 722077-005[...]

  • Page 2

    Disclaimer Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may appear in this document. Intel makes no commitment to update nor to keep current the i[...]

  • Page 3

    iii Contents 1 Description Server Board Features .......................................................................................................... 7 Back Panel Connectors ................................................................................................ 8 Server Board Connector and Component Locations ........................[...]

  • Page 4

    iv Contents Setup Menus .............................................................................................................. 36 Main Menu ................................................................................................................. 37 Advanced Menu .......................................................................[...]

  • Page 5

    L440GX+ Server Board Product Guide v 4 Solving Problems Resetting the System .......................................................................................................... 85 Fault Resilient Booting ........................................................................................................ 85 Initial System Startup ........[...]

  • Page 6

    vi Contents Ensure Host Computer and Accessory Module Certifications ................................... 107 Prevent Power Supply Overload ............................................................................... 107 Place Battery Marking on Computer ......................................................................... 108 Use Only for In[...]

  • Page 7

    7 1 Description Server Board Features Table 1 . Server Board Features Feature Description Processor Installed: Up to two Intel ® Pentium ® II or Pentium III processors (with 100 MHz system bus) operating at 1.8 V to 3.5 V. The server board’s voltage regulator is automatically programmed by the processor’s VID pins to provide the required volt[...]

  • Page 8

    8 Description Back Panel Connectors Figure 1 . Back Panel Connectors A. Mouse connector B. Keyboard connector C. Parallel Port connector D. Serial Port connectors E. Network connector F. Green NIC LED G. Orange NIC LED H. USB connectors I. Video connector Table 2 . NIC LEDs NIC LED Color If it's on If it's blinking If it's off Orange[...]

  • Page 9

    L440GX+ Server Board Product Guide 9 Server Board Connector and Component Locations Figure 2 . Server Board Connector and Component Locations A. Fansink connector 2 B. Secondary processor C. Fansink connector 1 D. Primary processor E. DIMM slots F. Main power connector G. ATX Aux power connector H. Fan connector FAN2A I. Floppy connector J. IDE con[...]

  • Page 10

    10 Description Processor Each Pentium II or Pentium III processor is packaged in a cartridge. The cartridge includes the processor core with an integrated 16 KB primary (L1) cache, the secondary (L2) cache, and a back cover. The processor implements the MMX ™ technology and maintains full backward compatibility with the 8086, 80286, Intel386 ™ [...]

  • Page 11

    L440GX+ Server Board Product Guide 11 / NOTE Use DIMMs that have been tested for compatibility with the server board. Contact your sales representative or dealer for a current list of approved memory modules. Check the Intel Customer Support website for the latest tested memory list: http://support.intel.com/support/motherboards/server/l440gx/compa[...]

  • Page 12

    12 Description Add-in Board Slots The server board has one full length ISA bus connector. ISA features: • Bus speed up to 8.33 MHz • 16 bit memory addressing • Type A transfers at 5.33 Mbps • Type B transfers at 8 Mbps • 8 or 16 bit data transfers • Plug and Play ready The server board has four full length standard PCI (PCI-33/32 bit) c[...]

  • Page 13

    L440GX+ Server Board Product Guide 13 Video The onboard, integrated Cirrus Logic CL-GD5480 64 bit VGA chip contains an SVGA controller that is fully compatible with these video standards: CGA, EGA, Hercules † Graphics, MDA, and VGA. The standard configuration comes with 2 MB of 10 ns onboard Synchronous Graphics Memory (SGRAM). The video controll[...]

  • Page 14

    14 Description / NOTE 18 inch maximum length of IDE cable on each channel: You can connect an IDE signal cable, up to a maximum of 18 inches each, to each IDE connector on the server board. Each cable c an support two devices, one at the end of the cable and one 6 inches from the end of the cable. Network Controller The server board includes a 10BA[...]

  • Page 15

    L440GX+ Server Board Product Guide 15 future versions of Microsoft Windows NT † x that support ACPI, the BIOS will support sleep states s0, s1, s4, and s5. • s0: Normal running state. • s1: Processor sleep state. No context will be lost in this state and the processor caches will maintain coherency. • s4: Hibernate or Save to Disk: The memo[...]

  • Page 16

    16 Description • Monitors the SDR/SEL timestamp clock • Manages the server board Field Replaceable Unit (FRU) information interface • Monitors the system management watchdog timer • Monitors the periodic SMI timer • Manages front panel NMI handling • Monitors the event receiver • Manages the ISA host and IMB interface • Controls sec[...]

  • Page 17

    L440GX+ Server Board Product Guide 17 Security To help prevent unauthorized entry or use of the server, Intel Server Control server management software monitors the system intrusion switch. Security with Mechanical Locks and Monitoring If installed, you can activate the chassis intrusion alarm switch. When the side door is opened, the switch transm[...]

  • Page 18

    18 Description • May enter either password to boot the server if Password on Boot is enabled in either the BIOS Setup or SSU. • May enter either password to exit secure mode. Secure Mode Configure and enable the secure boot mode by using the SSU. When secure mode is in effect: • You can boot the server and the operating system will run, but y[...]

  • Page 19

    L440GX+ Server Board Product Guide 19 Summary of Software Security Features The table below lists the software security features and describes what protection each offers. In general, to enable or set the features listed here, you must run the SSU and go to the Security Subsystem Group, menu. The table also refers to other SSU menus and to the Setu[...]

  • Page 20

    20 Description Table 3 . Software Security Features (continued) Feature Description Control access to the system other than SSU: set user password To control access to using the system, set a user password and enable it through Setup or the SSU. To disable a password, change it to a blank entry or press CTRL-D in the Change Password menu of the Use[...]

  • Page 21

    21 2 Upgrading Tools and Supplies Needed • Phillips (cross head) screwdriver (#1 bit and #2 bit) • Jumper removal tool or needle nosed pliers • Pen or pencil • Antistatic wrist strap and conductive foam pad (recommended) Warnings and Cautions These warnings and cautions apply throughout this chapter. Only a technically qualified person shou[...]

  • Page 22

    22 Upgrading top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jump[...]

  • Page 23

    L440GX+ Server Board Product Guide 23 Figure 3 . Server Board Screw Hole Locations Removing the Server Board CAUTION The server board can be extremely sensitive to ESD and always requires careful handling. After removing it from the server, place it component side up on a nonconductive, static free surface to prevent shorting out the battery leads.[...]

  • Page 24

    24 Upgrading Memor y Installing DIMMs CAUTIONS Use extreme care when installing a DIMM. Applying too much pressure can damage the socket. DIMMs are keyed and can be inserted in only one way. Mixing dissimilar metals may cause later memory failures resulting in data corruption. Only install DIMMs with gold-plated edge connectors in gold -plated sock[...]

  • Page 25

    L440GX+ Server Board Product Guide 25 Figure 4 . Installing DIMMs Removing DIMMs CAUTION Use extreme care when removing a DIMM. Too much pressure can damage the socket slot. Apply only enough pressure on the plastic ejector levers to release the DIMM. 1. Observe the safety and ESD precautions at the beginning of this chapter. 2. Open the server. 3.[...]

  • Page 26

    26 Upgrading Processors WARNING If the server has been running, any installed processor and heat sink on the processor board(s) will be hot. To avoid the possibility of a burn, be careful when removing or installing server board components that are located near processors. CAUTIONS Processor must be appropriate: You may damage the server if you ins[...]

  • Page 27

    L440GX+ Server Board Product Guide 27 CAUTION This is a difficult process. Do not pull the tab of the retention mechanism back too far, as damage to either the retention mechanism or server board can occur. Pull the tab of the retention mechanism back just far enough for the retention lock to free the processor. 4. Put the processor in a piece of c[...]

  • Page 28

    28 Upgrading Installing a Processor 1. Observe the safety and ESD precautions at the beginning of this chapter and the additional cautions given here. 2. If your server has one processor and you are ADDING a second, then you must remove the termination card from the secondary processor slot. Carefully pull back the tab of the retention mechanism wi[...]

  • Page 29

    L440GX+ Server Board Product Guide 29 3. If your server has one processor and you are REPLACING it, leave the termination board intact in the empty secondary slot. Remove the processor you want to replace. See “Removing a Processor” on page 26 . 4. If your server has two processors and you are REPLACING one or both, remove the appropriate one(s[...]

  • Page 30

    30 Upgrading Replacing the Back up Battery The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service repres[...]

  • Page 31

    L440GX+ Server Board Product Guide 31 Figure 7 . Replacing the Lithium Battery 1. Observe the safety and ESD precautions at the beginning of this chapter. 2. Open the chassis. 3. Insert the tip of a small flat bladed screwdriver, or equivalent, under the tab in the plastic retainer. 4. Gently push down on the screwdriver to lift the battery. 5. Rem[...]

  • Page 32

    32 Upgrading[...]

  • Page 33

    33 3 Configuration Software and Utilities This chapter describes the Power On Self Test (POST) and server configuration utilities. The table below briefly describes the utilities. Table 4 . Configuration Utilities Utility Description and brief procedure Page BIOS Setup If the system does not have a diskette drive, or the drive is disabled or miscon[...]

  • Page 34

    34 Configuration Software and Utilities Power On Self Test (POST) Each time you turn on the system, POST starts running. POST checks the server board, processor, memory, keyboard, and most installed peripheral devices. During the memory test, POST displays the amount of memory that it is able to access and test. The length of time needed to test me[...]

  • Page 35

    L440GX+ Server Board Product Guide 35 Using BIOS Setup This section describes the BIOS Setup options. Use Setup to change the server configuration defaults. You can run Setup with or without an operating system being present. Setup stores most of the configuration values in battery backed CMOS; the rest of the values are stored in flash memory. The[...]

  • Page 36

    36 Configuration Software and Utilities Starting Setup You can enter and start Setup under several conditions: • When you turn on the server, after POST completes the memory test • When you reboot the server by pressing <Ctrl+Alt+Del> while at the DOS operating system prompt • When you have moved the CMOS jumper on the server board to t[...]

  • Page 37

    L440GX+ Server Board Product Guide 37 Main Menu You can make the following selections on the Main Menu itself. Use the submenus for other selections. Feature Choices Description System Time HH:MM:SS Sets the system time. System Date MM/DD/YYYY Sets the system date. Legacy Diskette A: Disabled 360KB 1.2 MB 720KB 1.44/1.25 MB 2.88 MB Selects the disk[...]

  • Page 38

    38 Configuration Software and Utilities Primary/Secondary IDE Master and Slave Submenu Feature Choices Description Type Auto None CD-ROM IDE Removable ATAPI Removable User Auto forces the server to attempt autodetection of the drive type. None informs the server to ignore this drive. CD ROM allows the manual entry of some fields described below. ID[...]

  • Page 39

    L440GX+ Server Board Product Guide 39 Keyboard Submenu Feature Choices Description Num Lock On Off Selects the power on state for Num Lock. Key Click Disabled Enabled Enables or disables the audible key click. Keyboard auto-repeat rate 30/sec 26.7/sec 21.8/sec 18.5/sec 13.3/sec 10/sec 6/sec 2/sec Sets the numbers of time per second a key will repea[...]

  • Page 40

    40 Configuration Software and Utilities Advanced Menu You can make the following selections on the Advanced Menu itself. Use the submenus for the three other selections that appear on the Advanced Menu. Feature Choices Description Installed OS Other Win95 Select Win95 if you are booting a Plug and Play capable operating system. Reset Configuration [...]

  • Page 41

    L440GX+ Server Board Product Guide 41 PCI Device, Slot 1 - Slot 6 Submenus Feature Choices Description Enable Master Enabled Disabled Enables selected device as a PCI bus master. Latency Timer Default 020h 040h 060h 080h 0A0h 0C0h 0E0h Minimum guaranteed time, in units of PCI bus clocks, that a device may be master on a PCI bus. CAUTION Do not chan[...]

  • Page 42

    42 Configuration Software and Utilities Integrated Peripheral Configuration Submenu (continued) Feature Choices Description Interrupt IRQ 5 IRQ 7 Selects the IRQ for LPT port. DMA channel DMA 1 DMA 3 Selects the DMA for LPT port (only used for ECP mode). Floppy disk controller Disabled Enabled Enables onboard diskette controller. Advanced Chipset C[...]

  • Page 43

    L440GX+ Server Board Product Guide 43 Security Menu You can make the following selections on the Security Menu itself. Enabling the Supervisor Password field requires a password for entering Setup. The passwords are not case-sensitive. Feature Choices Description User Password is Clear Set Status only; user cannot modify. Once set, this can be disa[...]

  • Page 44

    44 Configuration Software and Utilities Server Menu You can make the following selections on the Server Menu itself. Feature Choices Description System Management Enters submenu. Console Redirection Enters submenu. PEP Management Enters submenu. Enable Sleep Button Disabled Enabled PCI IRQs to IO-APIC mappings Disabled Enabled Enabled - BIOS can de[...]

  • Page 45

    L440GX+ Server Board Product Guide 45 System Management Submenu (continued) Feature Choices Description EMP Hangup Line String ATH Sets the Hangup Line Sequence for the modem being used for EMP. Used in EMP modem mode. Modem Init String AT&F0S0=1S14=0&D Sets the initialization string for the modem being used for EMP. Used in EMP modem mode.[...]

  • Page 46

    46 Configuration Software and Utilities Console Redirection Submenu Feature Choices Description COM Port Address Disabled 3F8 2F8 3E8 When enabled, console redirection uses the I/O port specified. 3F8 - typically is COM1 2F8 - typically is COM2 All keyboard/mouse and video will be directed to this port. This is designed to be used only under DOS in[...]

  • Page 47

    L440GX+ Server Board Product Guide 47 PEP Management Submenu Verify in BIOS Setup of your server board whether or not your system BIOS includes PEP. If not, when it becomes available, you can download it from the Intel Customer Support website: http://support.intel.com/support/motherboards/server/l440gx Feature Choices Description PEP Filter Events[...]

  • Page 48

    48 Configuration Software and Utilities PEP Filter Submenu This submenu allows you to set which events or error conditions cause the system to page you. Feature Choices Description PEF Enable Disable Enable Enables the Platform Event Filtering. If this is enabled, and one of the events you enable below occurs, the server will page you using the Pag[...]

  • Page 49

    L440GX+ Server Board Product Guide 49 Extended RAM Step Choice Description 1 MB Tests extended memory once per MegaByte 1 KB Tests extended memory once per KiloByte Every Location Tests all extended memory No Memory test No extended memory is tested Boot Device Priority Use the up or down arrow keys to select a device; then press the <+> or &[...]

  • Page 50

    50 Configuration Software and Utilities Removable Devices For options on this menu, use the up or down arrow keys to select a device, then press the <+> or < - > keys to move the device higher or lower in the boot priority list. Option Description 1. Legacy Floppy Drive Refers to the onboard 3.5” floppy drive. Removable IDE media may [...]

  • Page 51

    L440GX+ Server Board Product Guide 51 When to Run the System Setup Utility The SSU is a DOS-based utility that supports extended system configuration operations for onboard resources and add-in boards. You can also view the system event log and to set system boot and security options. Use the SSU when you need to • add and remove boards affecting[...]

  • Page 52

    52 Configuration Software and Utilities Running the SSU • Running the SSU Locally Running the ssu.bat file provided on the SSU media starts the SSU. If the server boots directly from the SSU media, the ssu.bat file is automatically run. If it boots from a different media, the SSU can be started manually or by another application. When the SSU sta[...]

  • Page 53

    L440GX+ Server Board Product Guide 53 5. This message appears: Please wait while the Application Framework loads.... 6. When the main window of the SSU appears, you can customize the user interface before continuing. Figure 8 . System Setup Utility Main Window[...]

  • Page 54

    54 Configuration Software and Utilities Customizing the SSU The SSU lets you customize the user interface according to your preferences. The AF sets these preferences and saves them in the AF.INI file so that they take effect the next time you start the SSU. There are four user customizable settings: • Color - this button lets you change the defa[...]

  • Page 55

    L440GX+ Server Board Product Guide 55 Resource Configuration Add-in (RCA) Window The RCA provides three major functions: • Creates representations of devices that cannot be di s covered by the system (ISA cards) • Modifies the contents of the system by adding and removing devices • Modifies the resources used by devices You can use the RCA wi[...]

  • Page 56

    56 Configuration Software and Utilities Adding and Removing ISA Cards Adding and removing cards through the RCA provides a way for the RCA to run its conflict detection algorithms on the resources requested by the cards. This alerts you to any possible problems with that particular card in the current configuration. • To add an ISA card: 1. Click[...]

  • Page 57

    L440GX+ Server Board Product Guide 57 Security Add-in Under this window, you can set the User and Administrator passwords, and security options. To Set the User Password 1. Click on the user password button. 2. Enter the password in the first field. 3. Confirm the password by entering it again in the second field. To Change or Clear the User Passwo[...]

  • Page 58

    58 Configuration Software and Utilities SEL Manager Add-in Clicking on the SEL Manager Add-in task brings up the Server Event Log (SEL) viewer. You can load and view the current SEL data stored in the BMC, save the currently loaded SEL data to a file, view previously saved SEL data, or clear the SEL. The SEL Viewer has the following menus: File The[...]

  • Page 59

    L440GX+ Server Board Product Guide 59 FRU Manager Add-in Clicking on the FRU Manager Add-in task brings up the Field Replaceable Unit (FRU) viewer. You can load and view the current FRU data stored in the BMC, save the currently loaded FRU data to a file, view previously saved FRU data. The FRU Viewer has the following menus: File The File menu has[...]

  • Page 60

    60 Configuration Software and Utilities SDR Manager Add-in Clicking on the SDR Manager Add-in task brings up the Sensor Data Record (SDR) viewer. You can load and view the current SDR data stored in the BMC, save the currently loaded SDR data to a file, view previously saved SDR data. The SDR Viewer has the following menus: File The File menu has t[...]

  • Page 61

    L440GX+ Server Board Product Guide 61 Platform Event Paging With Platform Event Paging (PEP), your server can be configured to automatically dial up a paging service and page you when a server management related event occurs. Platform events include temperature out-of-range, voltage out-of-range, chassis intrusion, and fan failure. If PEP is enable[...]

  • Page 62

    62 Configuration Software and Utilities Emergency Management Port Console The Emergency Management Port (EMP) Console is a software application designed to run on a Windows 95 or Windows NT 4.0 workstation and provides a server administrator’s interface to the Emergency Management Port (EMP) of the L440GX+ server. This interface allows remote ser[...]

  • Page 63

    L440GX+ Server Board Product Guide 63 How EMP Console Works The EMP shares use of the COM2 port with the system on the server. When the EMP has control of the port, the port operates in command mode. When the system has control, the port operates in console redirect mode. When connecting to a server, the EMP Console checks to determine the mode of [...]

  • Page 64

    64 Configuration Software and Utilities Figure 10 . EMP Console in Redirect State Figure 10 shows EMP Console window in redirect mode with the terminal window. The text that appears on the server monitor displays in the Redirect window. Availability of the various EMP Console features are determined by two factors: the BIOS EMP access mode and if t[...]

  • Page 65

    L440GX+ Server Board Product Guide 65 Table 7 . EMP Console Access Modes (Server not configured for console redirection) Mode Server is powered off During BIOS POST After OS boots Disabled Redirect window appears, but is blank Redirect window appears, but is blank Redirect window appears, but is blank Pre-boot EMP commands available EMP commands av[...]

  • Page 66

    66 Configuration Software and Utilities Setting up the Server for the EMP To use the EMP, you must configure the server's BIOS with specific settings. These settings are found in two submenus of the BIOS Server menu, the System Management Submenu and the Console Redirection submenu. The BIOS settings section, found earlier in this document, sh[...]

  • Page 67

    L440GX+ Server Board Product Guide 67 Main EMP Console Window The main EMP Console window provides a graphical user interface (GUI) to access server control operations and to launch the management plug-ins. At the top of the window is the menu and tool bar. These provide the options to initiate plug-ins and other support features. A status bar at t[...]

  • Page 68

    68 Configuration Software and Utilities EMP Console Main Menu • File  Exit - exits EMP Console. • Connect  Disconnect - disconnects the server connection.  [Re]Connect - displays the connect dialog.  A list of the five most recent modem connections. Click on one of these server names to initiate a connection. • Action  Power On[...]

  • Page 69

    L440GX+ Server Board Product Guide 69 Connect When [Re]Connect is selected from the Connect menu, the Connect dialog in Figure 11 is displayed. This dialog allows you to connect to a server. If the client machine is already connected to a server, initiating connection generates a warning message. The message indicates that the existing connection w[...]

  • Page 70

    70 Configuration Software and Utilities Power On/Off Selecting Power On/Off from the Action menu displays the Power on/off dialog. This dialog provides commands to remotely power on or power off the server. Figure 12 . Power On/Off Dialog Options available in the dialog are: • Power ON - powers on the server. • Power OFF - powers off the server[...]

  • Page 71

    L440GX+ Server Board Product Guide 71 Options available in the dialog are: • System Reset - resets the server with the selected post-reset options. This operation is not allowed if the server is configured in RESTRICTED mode for EMP operations. • Post-reset option - sets the post-reset option that will be in effect after reset. The options are [...]

  • Page 72

    72 Configuration Software and Utilities • Connect - displays the Connect dialog with the server from the Phonebook's Server dropdown list box already populating the Connect dialog's Server field. • Cancel - exits the Connect dialog without taking any action. • Help - displays the help information for this dialog. Management Plug-ins[...]

  • Page 73

    L440GX+ Server Board Product Guide 73  By Event - displays all the events in the SEL of a particular event type; for example, threshold, digital, or discrete. A pop-up menu lets you select the event type to be displayed.  Settings - changes several operating parameters for the SEL Viewer. This menu displays the following suboptions: • Displ[...]

  • Page 74

    74 Configuration Software and Utilities FRU Viewer The FRU Viewer allows you to view the server's FRU (Field Replaceable Unit) data from the server's Front Panel FRU information area. The options available in the FRU Viewer are: • View all FRU records • View FRU summary info • Set FRU display mode to either Hex or verbose mode • C[...]

  • Page 75

    L440GX+ Server Board Product Guide 75 FRUSDR Load Utility The Field Replacement Unit (FRU) and Sensor Data Record (SDR) Load Utility is a DOS-based program used to update the server management subsystem’s product level FRU, SDR, and the Desktop Management Interface (DMI) nonvolatile storage components (EEPROMs). The load utility • discovers the[...]

  • Page 76

    76 Configuration Software and Utilities How You Use the FRUSDR Load Utility This utility is compatible with ROM-DOS Ver. 6.22, MS-DOS † Ver. 6.22, and later versions. The utility accepts CFG, SDR and FRU load files. The executable file for the utility is frusdr.exe. The utility requires the following supporting files: • one or more .fru files d[...]

  • Page 77

    L440GX+ Server Board Product Guide 77 Displaying DMI Area The DMI area is displayed in ASCII format when the field is ASCII or as a number when the field is a number. Each DMI area displayed is headed with the DMI area designated name. Each field has a field name header followed by the field in ASCII or as a number. Displaying FRU Area The FRU area[...]

  • Page 78

    78 Configuration Software and Utilities Updating the SDR Nonvolatile Storage Area After the utility validates the header area of the supplied SDR file, it updates the SDR repository area. Before programming, the utility clears the SDR repository area. The SDR file is loaded via the .cfg File. Then the utility filters all tagged SDRs depending on th[...]

  • Page 79

    L440GX+ Server Board Product Guide 79 Upgrading the BIOS Preparing for the Upgrade Before you upgrade the BIOS, prepare for the upgrade by recording the current BIOS settings, obtaining the upgrade utility, and making a copy of the current BIOS. Recording the Current BIOS Settings 1. Boot the computer and press <F2> when you see the message: [...]

  • Page 80

    80 Configuration Software and Utilities Creating the BIOS Upgrade Floppy Diskette The BIOS upgrade file is a compressed self-extracting archive that contains the files you need to upgrade the BIOS. 1. Copy the BIOS upgrade file to a temporary directory on your hard disk. 2. From the C: prompt, change to the temporary directory. 3. To extract the f[...]

  • Page 81

    L440GX+ Server Board Product Guide 81 Recovering the BIOS It is unlikely that anything will interrupt the BIOS upgrade; however, if an interruption occurs, the BIOS could be damaged. The following steps explain how to recover the BIOS if an upgrade fails. The following procedure use recovery mode for the Setup program. / NOTE Because of the small a[...]

  • Page 82

    82 Configuration Software and Utilities Using the Firmware Update Utility The Firmware Update Utility is a DOS-based program used to update the Baseboard Management Controller’s firmware code. You only need to run the Firmware Update Utility if new firmware code becomes necessary. Running the Firmware Update Utility 1. Create a DOS bootable diske[...]

  • Page 83

    L440GX+ Server Board Product Guide 83 Using the Adaptec SCSI Utility The Adaptec SCSI utility detects the SCSI host adapters on the server board. The utility runs out of BIOS and is used to • Change default values • Check and/or change SCSI device settings that may conflict with those of other devices in the server Running the SCSI Utility 1. W[...]

  • Page 84

    84 Configuration Software and Utilities[...]

  • Page 85

    85 4 Solving Problems This chapter helps you identify and solve problems that might occur while you are using the system. Resetting the System To do this: Press: Soft boot reset, which clears system memory and reloads the operating system. <Ctrl+Alt+Del> Clear system memory, restart POST, and reload the operating system. Reset button Cold boo[...]

  • Page 86

    86 Solving Problems Checklist q Are all cables correctly connected and secured? q Are the processors or processor termination board fully seated in their slots on the server board? q Are all add-in ISA and PCI boards fully seated in their slots on the server board? q Are all switch and jumper settings on the server board correct? q Are all jumper a[...]

  • Page 87

    L440GX+ Server Board Product Guide 87 After the System Has Been Running Correctly Problems that occur after the system hardware and software have been running correctly often indicate equipment failure. Many situations that are easy to correct, however, can also cause such problems. Checklist q If you are running the software from a diskette, try a[...]

  • Page 88

    88 Solving Problems More Problem Solving Procedures This section provides a more detailed approach to identifying a problem and locating its source. Preparing the System for Diagnostic Testing CAUTION Turn off devices before disconnecting cables: Before disconnecting any peripheral cables from the system, turn off the system and any external periph[...]

  • Page 89

    L440GX+ Server Board Product Guide 89 Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • There is no beep or an incorrect beep pattern. • No characters appear on screen. • Characters on the screen appear distorted or incorrect. • System cooling fan[...]

  • Page 90

    90 Solving Problems 3. If there are still no characters on the screen after you reboot the system and POST emits a beep code, write down the beep code you hear. This information is useful for your service representative. See “ Port-80 Codes and Countdown Codes ” on page 94 . 4. If you do not receive a beep code and characters do not appear, the[...]

  • Page 91

    L440GX+ Server Board Product Guide 91 Diskette Drive Activity Light Does Not Light Check the following: q Are the diskette drive power and signal cables properly installed? q Are all relevant switches and jumpers on the diskette drive set correctly? q Is the diskette drive properly configured? q Is the diskette drive activity light always on? If so[...]

  • Page 92

    92 Solving Problems / NOTE Front panel hard disk LED indicates IDE and SCSI devices : The hard disk drive activity light on the front panel lights when either an IDE hard disk drive, or a SCSI device controlled by the onboard SCSI host controller, is in use. This LED does not display CD-ROM activity. Cannot Connect to a Server q Make sure you are u[...]

  • Page 93

    L440GX+ Server Board Product Guide 93 The controller stopped working when an add-in adapter was installed. q Make sure the cable is connected to the port from the onboard network controller. q Make sure your PCI BIOS is current. Try the “PCI Installation Tips” below. q Make sure the other adapter supports shared interrupts. Also, make sure your[...]

  • Page 94

    94 Solving Problems Error and Informational Messages When you turn on the system, POST displays messages that provide information about the system. If a failure occurs, POST emits beep codes that indicate errors in hardware, software, or firmware. If POST can display a message on the video display screen, it causes the speaker to beep twice as the [...]

  • Page 95

    95 5 Technical Reference This chapter includes the following: • Environmental specifications • Board interrupts • Electromagnetic Compatibility (EMC) notices[...]

  • Page 96

    96 Technical Reference Connectors The figure shows connector locations on the server board. This section provides pin information about the connectors. Figure 15 . Connector Locations A. Fansink connector 2 I. ISOL IMB B. Fansink connector 1 J. Fan connector 1 C. Main power connector K. Server monitor module (SMM) connector D. ATX Aux power connect[...]

  • Page 97

    L440GX+ Server Board Product Guide 97 ATX Style Front Panel Connector Figure 16 . ATX Style Front Panel Connector Table 8 . ATX Style Front Panel Connector Pinout Connector Pin Signal A. Power switch 1 2 3 Power switch GND N/C B. Hard drive activity LED 4 5 6 7 Current limited +5V Key HD activity LED Current limited +5V C. Speaker 8 9 10 11 GND N/C[...]

  • Page 98

    98 Technical Reference Main Power Connector Table 9 . Main Power Connector Pinout Pin Signal Pin Signal 1 +3.3V 13 +3.3V 2 +3.3V 14 -12V 3 COM 15 COM 4 +5V 16 PS_ON 5 COM 17 COM 6 +5V 18 COM 7 COM 19 COM 8 PWR_OK 20 -5V 9 +5VSB 21 +5V 10 +12V 22 +5V 11 +12V 23 +5V 12 +3.3V 24 COM Fan Interface The server board has five 3-pin fan connectors that are[...]

  • Page 99

    L440GX+ Server Board Product Guide 99 Server Board Jumpers Figure 17 . Jumper Locations Table 11 . Server Board Jum per Summary Jumper Block Jumper Name Pins (default in bold) What it does at system reset J5A2 WOL ENABLE 1-2, Disabled Disables Wake On LAN. If your power supply does not provide 0.8 A of +5 V Standby current, you must move the WOL En[...]

  • Page 100

    100 Technical Reference Table 11 . Server Board Jumper Summary (continued) Jumper Block Jumper Name Pins (default in bold) What it does at system reset J2J1 CMOS CLR 1-2, Protect Preserves the contents of NVRAM. 2-3, Erase Replaces the contents of NVRAM with the manufacturing default settings. J2J1 PSWD CLR 5-6, Protect Maintains the current system[...]

  • Page 101

    L440GX+ Server Board Product Guide 101 CMOS Jumper The jumper at pins 1, 2, and 3 controls whether settings stored in CMOS nonvolatile memory (NVRAM) are retained during a system reset. Procedure to restore the system’s CMOS and RTC to default values: 1. See “ General Procedure to Change Jumper Setting ” on page 100 . 2. Move the CMOS jumper [...]

  • Page 102

    102 Technical Reference Recovery Boot Jumper The jumper at pins 9, 10, and 11 controls whether the system attempts to boot using the BIOS programmed in the boot block area of the FLASH memory. This should be used only if the operational area of the BIOS is corrupted or needs to be upgraded. Contact your local service representative before doing thi[...]

  • Page 103

    L440GX+ Server Board Product Guide 103 Procedure to permit boot block erasing and programming: 1. See “ General Procedure to Change Jumper Setting ” on page 100 . 2. Move the boot block jumper from pins 13 and 14 to pins 14 and 15 to erase and program the BIOS boot block. 3. Reinstall the side cover for your safety, and connect the power cord t[...]

  • Page 104

    104 Technical Reference[...]

  • Page 105

    105 6 Regulatory and Integration Information Regulatory Compliance This server baseboard complies with the following safety and EMC regulations when correctly installed in a compatible host system. Table 12 . Safety Regulations Regulation Title UL 1950/CSA950, 3 rd edition, Dated 07-28-95 Bi-National Standard for Safety of Information Technology Eq[...]

  • Page 106

    106 Regulatory and Integration Information Installation Instructions CAUTION Follow these guidelines to meet safety and regulatory requirements when installing this board assembly. Read and adhere to all of these instructions and the instructions supplied with the host computer and associated modules. If the instructions for the host computer are i[...]

  • Page 107

    L440GX+ Server Board Product Guide 107 Ensure Host Computer and Accessory Module Certifications Make sure that the host computer, any added subassembly (such as a board or drive assembly, including internal or external wiring), are certified for the region(s) where the end product will be used. Marks on the product are proof of certification. Certi[...]

  • Page 108

    108 Regulatory and Integration Information Place Battery Marking on Computer There is insufficient space on this server board to provide instructions for replacing and disposing of the battery. The following warning must be placed permanently and legibly on the host computer as near as possible to the battery. WARNING Danger of explosion if battery[...]

  • Page 109

    109 7 Equipment Log and Power Consumption Worksheets Equipment Log Use the blank equipment log provided here to record information about your system. You will need some of this information when you run the SSU. Item Manufacturer Name and Model Number Serial Number Date Installed System Server board Primary Processor speed and cache Secondary Proces[...]

  • Page 110

    110 Equipment Log and Power Consumption Worksheets Equipment Log (continued) Item Manufacturer Name and Model Number Serial Number Date Installed[...]

  • Page 111

    L440GX+ Server Board Product Guide 111 Current Usage As an overall current usage limitation on the power supply, do not exceed a combined power output of 167 watts for the +5 and +3.3 volt outputs. The ISA slots on the server board are rated at a maximum of 4.5 amperes per slot. The ISA specification recommends supporting an average of 2.0 amperes [...]

  • Page 112

    112 Equipment Log and Power Consumption Worksheets Worksheet, Calculating DC Power Usage 1. List the current for each board and device in the appropriate voltage level column. 2. Add the currents in each column. Then go to the next worksheet. Table 14 . Power Usage Worksheet 1 Current (maximum) at voltage level: Device +3.3 V +5 V –5 V +12 V –1[...]

  • Page 113

    L440GX+ Server Board Product Guide 113 Worksheet, Total Combined Power Used by the System 1. From the previous worksheet, enter the total current for each column. 2. Multiply the voltage by the total current to get the total wattage for each voltage level. 3. Add the total wattage for each voltage level to arrive at a total combined power usage on [...]

  • Page 114

    114 Equipment Log and Power Consumption Worksheets[...]

  • Page 115

    L440GX+ Server Board Product Guide 115 Index A Add-in boards IDE bus slots, 12 ISA, 51 ISA slots, 12 PCI, 51 administrative password, 17 limiting access to SCU, 19 Advanced Menu, configuring in Setup, 40 audible beep error codes, 34 B Back Panel Connectors, 8 battery disposing of safely, 30 installing, 31 removing, 30 beep codes, 34 BIOS changing t[...]

  • Page 116

    116 Index D diagnostics, preparing system for testing, 88 DIMM (memory) installing, 24 removing, 25 diskette drive controller, 13 enabling/disabling floppy writes, 19 no booting in secure mode without password, 19 reconfiguring if cannot enter Setup, 35 running SCU from, 33, 34 E Emergency Management Port FRU viewer, 74 main console window, 67 phon[...]

  • Page 117

    L440GX+ Server Board Product Guide 117 M - N Main power supply, connector, 98 memory amount tested, POST, 34 capacity, 7 DIMM requirements, 11 DIMM size, 10 expansion, 10 installing DIMM, 24 removing DIMM, 25 video amount, 7 video size, 13 what type to install, 7 messages, error and informational, 94 monitoring server status, 15 mouse compatibility[...]

  • Page 118

    118 Index S SCI files, 51 SCSI, bus termination requirements, 13 SCSI controller, 13 SCU administrative password limits access to, 19 changing configuration, 33 diskette drive required to run SCU, 33 inactivity (lockout) timer, 14 software locking feature, 17 secure mode, 18 affects boot sequence, 20 enter by setting passwords, 19 locking reset and[...]

  • Page 119

    L440GX+ Server Board Product Guide 119 System setup utility CFG files, 51 customizing, 54 defining an ISA card, 55 exiting, 60 launching a task, 54 location, 50 removing an ISA card, 56 running, 52 locally, 52 remotely, 52 SCI files, 51 when to run, 51 T - U termination board, removing, 28 timer keyboard or mouse inactive, 14 lockout (inactivity), [...]

  • Page 120

    120 Index[...]