Intel C50277-001 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Intel C50277-001, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Intel C50277-001 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Intel C50277-001. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Intel C50277-001 should contain:
- informations concerning technical data of Intel C50277-001
- name of the manufacturer and a year of construction of the Intel C50277-001 item
- rules of operation, control and maintenance of the Intel C50277-001 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Intel C50277-001 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Intel C50277-001, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Intel service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Intel C50277-001.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Intel C50277-001 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Intel® Entry Server Chassis SC5275-E User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number: C50277-001[...]

  • Page 2

    Intel® Entry Server Chassis SC5275-E User Guide ii Disclaimer Information in this document is provided in connection with Intel ® products. No license, expres s or implied, by estoppel or otherwise, to any intellectual property rights i s granted by this document. Except a s provided in Intel’s Terms and Conditions of Sale for such products, In[...]

  • Page 3

    Preface Intel® Entry Server Chas sis SC5275-E User Guide iii Preface About this Manual Thank you for purchasing and using the Intel ® Entry Server Chassis SC5275-E. This manual is written for system technicians w ho are responsible for tr oubleshooting, upgrading, and reparing this server chassis. This document provides a brief overview of the fe[...]

  • Page 4

    Preface Intel® Entry Server Chassis SC5275-E User Guide iv Additional Information and Software If you need more information about this product or inf ormation about the accessories that can be used with this server chassis, use the following resources: For in-depth technical information ab out this product, including BIOS settings and chipset info[...]

  • Page 5

    Preface Intel® Entry Server Chas sis SC5275-E User Guide v Safety Informa tion WARNING Before working with your server product, whet her you are using this guide or any other resource as a reference, pay close attention to th e safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with ex[...]

  • Page 6

    Preface Intel® Entry Server Chassis SC5275-E User Guide vi strap attached to chassis ground  any unpainted metal surface  on your server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or f[...]

  • Page 7

    Preface Intel® Entry Server Chassis SC5275-E User Guide vii 5. Provide some electrostatic discharge (ESD ) protection by wearing an antistatic wrist strap attached to chassis ground of the system—any unpai nted metal surface—when handling components. 6. Do not operate the system wit h the chassis covers removed. After you have completed the si[...]

  • Page 8

    Preface Intel® Entry Server Chassis SC5275-E User Guide viii Benutzer können am Netzgerät dieses Prod ukts keine R eparaturen vornehmen. Das Produkt enthält möglicherweis e mehrer e Netzgeräte. Wartungsarbeiten müssen von qualifizierten Technikern ausgeführt werden. Versuchen Sie nicht, das mitgelieferte Netzk abel zu ändern oder zu verw e[...]

  • Page 9

    Preface Intel® Entry Server Chassis SC5275-E Us er Guide ix durch denselben oder ein en entsprechenden, vom Herstell er empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisun gen des Herstellers entsprechend. Das System wurde für den Betrieb in einer normalen Bür o umgebung entwickelt. Der Standort sollte: saube[...]

  • Page 10

    Preface Intel® Entry Server Chassis SC5275-E User Guide x CONSIGNES DE SÉCURITÉ -Lorsque vous ouvrez le boîtier pour accéder à l’intéri eur du système, suivez les consignes suivantes: 1. Mettez hors tension tous les périphériques conn ectés au s ystème. 2. Mettez le système hors tension en mettant l’interrupteur génér al en posit[...]

  • Page 11

    Preface Intel® Entry Server Chassi s SC5275-E Us er Guide xi télécommunications de votre modem d urant un orage. Muni d'une prise murale correctement mise à la terre. Suffisamment spacieux pour vous permettre d' accéder a ux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Instrucciones d[...]

  • Page 12

    Preface Intel® Entry Server Chassis SC5275-E User Guide xii sistema. 2. Compruebe que los cables, las placas a dici onales y otros componentes s e haya n instalado correctamente. 3. Incorpore las tapas al chasis mediante lo s tornillos extraído s anteriormente, tensándol os firmemente. 4. Inserte el bloqueo de seguridad en e l sistema y bloquée[...]

  • Page 13

    Preface Intel® Entry Server Chassi s SC5275-E User Guide xiii PASSI DI SICUREZZA: Qualora si rimuovano le coperture del tel aio per accedere all’interno del sistema, seguire i segue nti passi: 1. Spegnere tutti i dispositivi perif erici collegati al sistema. 2. Spegnere il sistema, usando il pulsante sp ento/acceso dell’inte rruttore del siste[...]

  • Page 14

    Preface Intel® Entry Server Chassis SC5275-E User Guide xiv[...]

  • Page 15

    Contents Intel® Entry Server Chas sis SC5275-E User Guide xv Contents Warnings ......................................................................................................... v 1 Chassis Description ....................................................................................... 1 Kit Contents......................................[...]

  • Page 16

    Contents Intel® Entry Server Chassis SC5275-E User Guide xvi Replacing a Front System Fan ..................................................................................... 31 Replacing a Rear System Fan ..................................................................................... 32 Replacing the Power Supply ..........................[...]

  • Page 17

    Contents Intel® Entry Server Chassis SC5275-E User Guide xvii Figure 6. Removing the 3.5-inch EMI Shield ............................................................................. 14 Figure 7. Installing a Floppy Drive ........................................................................................... .. 15 Figure 8. Removing EMI Shield[...]

  • Page 18

    Contents Intel® Entry Server Chassis SC5275-E User Guide xviii[...]

  • Page 19

    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 1 1 Chassis Description Kit Contents The chassis subassembly kit includes this product guide and a box that includes two pair of 5. 25- inch external drive rails, four different types of mounting screws, and two brackets for the optional SCSI hot-swap hard drive bay (SCSI hot-s [...]

  • Page 20

    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 2 Chassis Front View TP00053 A B C E F D A. Front panel controls and indicators B. 5.25-inch removable media dri ve bays C. 3.5-inch removable medi a drive bay D. Internal hard drive bay cage (behind do or) E. Security lock F. USB port[...]

  • Page 21

    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 3 Front Panel Controls and Indicators TP00080 A C E G I B D F H A. Power / sleep LED B. Power button C. NMI button D. Reset button E. Sleep button F. NIC 1 activity LED G. NIC 2 activity LED H. Hard drive activity LED I. Status LED * Some items may not be su ppo rted by all serv[...]

  • Page 22

    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 4 Chassis Rear View TP00834 B A F D E C A. Alternate Serial B port knockout B. Alternate ICMB or external SCSI knockout C. AC input power connector D. Power supply E. Fan F. I/O ports* G. Expansion slot covers H. ICMB or external SCSI knockout I. Serial B port knockout J. Locati[...]

  • Page 23

    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 5 Peripherals 5.25-inch Removable Media Drive Bays The upper bays are designed for removable medi a peripherals. You can install up to two half-height peripherals. 3.5-inch Hard Drive Bays The chassis supports up six drives depending on the power budget. The drives are installed[...]

  • Page 24

    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 6 Power Supply The 600-Watt PFC non-redundant power supply is auto ranging for either 100-127 VAC or 200-240 VAC operation. Checking the Power Cord WARNING Do not attempt to modify or use a supplied AC power cord if it is not the exact type required. The power supply cord is the[...]

  • Page 25

    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 7 Mechanical Locks The front bezel has a two-position lock to prevent access to the hard drives and the interior of the chassis. A padlock loop is included with the chassis and can be installed at the rear of the chassis. TP00055 B A A. Location to install padlock loo p B. Front[...]

  • Page 26

    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 8[...]

  • Page 27

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 9 2 Setting Up the Chassis This chapter describes how to set the server up fo r the first time. With the exception of replacing the front panel board (discussed in Chapter 4), it is necessary to remove only the left access cover, not the cover at the right. Tools and Supplies[...]

  • Page 28

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 10 Warnings and Cautions These warnings and cautions apply whenever you remove the access cover(s) to access components inside the server. Only a technically qualified person should integrate and configure the server. WARNINGS The power button on the front panel DOES NOT turn[...]

  • Page 29

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 11 Remove the Access Cover Observe the safety and ESD precautions at the beginn ing of this chapter. For ease of installation, before beginning lay the chassis on its right si de, with the left access cover facing up. 1. If the shipping screws are installed, re move them (num[...]

  • Page 30

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 12 Remove the Front Bezel 1. Pull the left side of the bezel forward to disengage the tabs (facing up in the following figure). See number 1 in the figure. 2. Remove the bezel from the tabs at the right side of the chassis (facing down in the following figure). See number 2 i[...]

  • Page 31

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 13 Install the I/O Shield ✏ NOTE An ATX 2.03-compliant I/O shield should be provided with your s erver board. The shield is required by Electromagnetic Interference (EMI) regulations. It minimizes EMI and ensures proper cooling of the server. The shield fits the rectangular[...]

  • Page 32

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 14 Install the Server Board Standoffs and Bumpers The location of the standoffs and bumpers varies by server board. Read and follow the instructions provided with the server board Quick Start User’s Guide for proper standoff and bumper placement. Install a 3.5-inch Floppy D[...]

  • Page 33

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 15 8. Slide the drive into the chassis. When prope rly positioned, the holes in the side of the drive align with the threaded holes in the chassis frame. 9. Secure the drive to the side of the chassis w ith two screws. Note that only two screws are required at the left side o[...]

  • Page 34

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 16 IDE Requirements If no drives are present on an IDE channel, the cab le must be removed. If only one drive is installed, it should be connected at the end of the cable. ✏ NOTE To disable the IDE controller: If you plan to disable the IDE controller to reuse the interrupt[...]

  • Page 35

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 17 3. Remove the drive from its protective wr apper and place it on an antistatic surface. 4. Record the drive model and seri al numbers in your equipment log. 5. Set any jumpers or switches on the drive accord ing to the drive manufacturer’s instructions. 6. Using four scr[...]

  • Page 36

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 18 7. Position the drive so the slide rails engage in th e chassis bay guide rails. Push the drive into the bay until the slide rails are flush with the chassis. 8. Use two screws for each slide rail to attach the device at the front of the chassis. 9. Connect the data and po[...]

  • Page 37

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 19 Install the Server Board 1. Remove and save the four screws that secure th e drive cage to the chassis. Two screws are at the front of the chassis and two are at the side of it. 2. Slide the drive cage out of the chassis. You ma y need to push the cage out from the inside [...]

  • Page 38

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 20 Installing 3.5-inch Hard Drive Six 3.5-inch half-height bays provide space for ha rd drives. For proper cooling, always install drives into the four center bays first ✏ NOTE The drive bay cage can only be fully populated with six hard drives if the power budget has the c[...]

  • Page 39

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 21 6. Slide the drive into the back of the drive cage along the rails in the cage. Install the drive with the component side facing down. The drive power and data connectors must face out the open side of the cage. 7. Push the drive in until the drive connect ors are flush wi[...]

  • Page 40

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 22 10. After all drives are installed into the cage, slid e the cage into the chassis, making sure the arrow and the screw tabs point toward the top of the chassis. 11. Insert and tighten the four screws removed in Step 1. 12. Attach data and power cables to the drive(s). TP0[...]

  • Page 41

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 23 Connect Cables to the Server Board See your server board product guide or Quick Start User’s Guide for connector locations. 1. Connect the power cables to the server board. • The large plug labeled P1 plugs into the main power connector on the server board • The plug[...]

  • Page 42

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 24 Installing an Add-in Board You may want to install an operating system before installing any add-in boards. If so, skip this step and return to it when you are ready. CAUTIONS Do not overload the server board by installing add-in boards that dr aw excessive current. Add-in[...]

  • Page 43

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 25 OM11961 A B C A. Snap-in slot cover B. Tapered foot C. Slot Figure 14. Installing an Add-in Board[...]

  • Page 44

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 26 Install the Front Bezel 1. Angle the bezel toward the chassis as shown by number 1 in the figure below. 2. Insert the latches on the right side of the bezel (facing down in the figure below) into the corresponding slots in the chassis. See number 2 in the figure. 3. Rotate[...]

  • Page 45

    2 Setting Up the Chassis Intel® Entry Server Chassis SC5275-E User Guide 27 Install the Access Cover 1. Place the cover so the tabs on the cover fit in to the slots on the server. The cover should be flush against the chassis. 2. Slide the cover forward until it stops (letter A in the figure below). 3. Slide the two thumb latches to the right to t[...]

  • Page 46

    [...]

  • Page 47

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 29 3 Maintaining Y our Server This chapter describes how to replace components in your server after it has been set up. Tools and Supplies Needed  Phillips (cross head) screwdriver (#2 bit)  Small flathead screwdriver  Antistatic wrist strap (recommended)  Needle[...]

  • Page 48

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 30 CAUTIONS ESD can damage disk drives, boards, and other parts. Perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antista tic wrist strap attached to chassis ground  any unpainted metal s[...]

  • Page 49

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 31 Replacing Fans The chassis contains two replaceable system fans . The power supply fan(s) are not replaceable. Your replacement fan should be the same size and type as the fan you are removing. Replacing a Front System Fan Standard Hard Drive Bay Cage The front system fan[...]

  • Page 50

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 32 9. Slide the new fan in through the fan opening. Make sure the airflow is towards the server board. This means the label should face the server board. 10. Replace the nylon rivets to attach the fan to the hard drive bay cage. 11. Replace the hard drive bay cage in the cha[...]

  • Page 51

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 33 Replacing the Power Supply WARNINGS Hazardous conditions, power supply : Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servic ing should be done by technically qualified personnel. To repl[...]

  • Page 52

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 34 Replacing the Front Panel Board 1. Remove the left access cover. 2. Remove the bezel. 3. Remove the two screws at the rear of the chassis that hold the right access cover in place. 4. Remove the right access cover. A rectangular opening at the right side of the chassis pr[...]

  • Page 53

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 35 8. Slide the end of front panel board cable throug h the front panel opening and attach it to the ne w front panel board. Attach the cable before inst alling the new front panel board into the chassis to ensure the cable pins line up correctly. TP00082 Figure 21. Attachin[...]

  • Page 54

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 36 Replacing the USB Cable 1. Remove the left access cover. 2. Remove the bezel. 3. Disconnect the existing USB cable from the server board. 4. Disconnect the bracket the attaches the USB cable to the front of the chassis. 5. Remove all add-in boards. ✏ NOTE When removing [...]

  • Page 55

    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 37[...]

  • Page 56

    [...]

  • Page 57

    4 Technical Reference Intel® Entry Server Chassis SC5275-E User Guide 39 4 T echnical Reference Power Supply Specifications 600 Watt Single Power Supply Input Voltages 600 Watt Power Supply  100-127 V ∼ at 50/60 Hz; 6.5 A max.  200-240 V ∼ at 50/60 Hz; 3.2 A max. 600 Watt Single Power Supply Output Voltages 600 Watt Power Supply The tabl[...]

  • Page 58

    4 Technical Reference Intel® Entry Server Chassis SC5275-E User Guide 40 System Environmental Specifications Table 5. Environmental Specifications Temperature Non-operating Operating –40 ° to 70 °C. 5 ° to 35 °C; derated 0.5 °C for every 1000 ft (305 m) to a maximum of 10,000 ft. Humidity Non-operating 95% relative humidity (non-condensing)[...]

  • Page 59

    Equipment Log and Worksheets Intel® Entry Server Chassis SC5275-E User Guide 41 Equipment Log and W orksheets Equipment Log Use the blank equipment log provided here to reco rd information about your ser ver. You will need some of this information when you run the SSU. Item Manufacturer Name and Model Nu mber Serial Number Date Installed Chassis S[...]

  • Page 60

    Equipment Log and Worksheets Intel® Entry Server Chassis SC5275-E User Guide 42 Equipment Log (continued) Item Manufacturer Name and Model Nu mber Serial Number Date Installed[...]

  • Page 61

    Equipment Log and Worksheets Intel® Entry Server Chassis SC5275-E User Guide 43 Current Usage Calculating Power Usage The total combined wattage for your configuration must be less than the wattage rating for your power supply. Use the two worksheets in this section to calculate the total used by your configuration. For current and voltage require[...]

  • Page 62

    Equipment Log and Worksheets Intel® Entry Server Chassis SC5275-E User Guide 44 Worksheet, Total Combined Power Used by the Server 1. From the previous worksheet, ente r the total current for each column. 2. Multiply the voltage by the total current to get the total wattage for each voltage level. 3. Add the total wattage for each voltage level to[...]

  • Page 63

    Regulatory and Compliance Information Intel® Entry Server Chassis SC5275-E User Guide 45 Regulator y and Compliance Inf ormation Product Regulatory Compliance Product Safety Compliance The Intel® Entry Server Chassis SC5275-E complies with the following safety requirements:  UL60950 – CSA 60950(USA / Canada)  EN60950 (Europe)  IEC60950[...]

  • Page 64

    Regulatory and Compliance Information Intel® Entry Server Chassis SC5275-E User Guide 46  GB 17625 - (Harmonics) CNCA Certification (China) Certifications / Registrations / Declarations  UL Certification (US/Canada)  CE Declaration of Conformity (CENELEC Europe)  FCC/ICES-003 Class A Attestation (USA/Canada)  VCCI Certification (Jap[...]

  • Page 65

    Regulatory and Compliance Information Intel® Entry Server Chassis SC5275-E User Guide 47 Regulatory Compliance Country Marking BSMI Certification Number & Class A Warning Taiwan GOST R Marking Russia RRL MIC Mark Korea China Compulsory Certification Mark China Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of[...]

  • Page 66

    Regulatory and Compliance Information Intel® Entry Server Chassis SC5275-E User Guide 48 This equipment has been tested and found to comp ly with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These lim its are designed to provide reasonable protection against harmful interference in a residential insta llation. Thi[...]

  • Page 67

    Regulatory and Compliance Information Intel® Entry Server Chassis SC5275-E User Guide 49 VCCI (Japan) English translation of the notice above: This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment. If th is is used near a radio or television receiver in a dome[...]

  • Page 68

    Regulatory and Compliance Information Intel® Entry Server Chassis SC5275-E User Guide 50 Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to. Interchanging or use of other component will void the UL[...]

  • Page 69

    Getting Help Intel® Entry Server Chassis SC5275-E User Guide 51 Getting Help World Wide Web http://support.intel.com/support/mot herboards/server/chassis/SC5275E Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card e x c h a n g e r a t e p l u s a p p l i c a b l e t a x e s . (Intel reserv[...]

  • Page 70

    Getting Help Intel® Entry Server Chassis SC5275-E User Guide 52 In Latin America Brazil 001-916-377- 0180 Mexico contact AT&T USA by dialing 001-800-462- 4240; once connected, dial 8 00-8 43-4481 Colombia contact AT&T USA by dialing 01-800-911- 0010; once connected, dial 8 00-8 43-4481 Costa Rica contact AT&T U SA by dialing 0-800- 0-1[...]

  • Page 71

    Warranty Intel ® Entry Server Platform SR1325TP1-E User Guide 53 W arranty Limited Warranty for Intel ® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel ® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly u[...]

  • Page 72

    Warranty Intel® Entry Server Chassis SC5275-E User Guide 54 Warranty Limitations and Exclusions These warranties replace al l other warra nties, expr essed or implied including, but not limited to, the implied warranties of merchantability and fitne ss for a particular purpose. Intel makes no expressed warranties beyond those stat ed here. Intel d[...]

  • Page 73

    Warranty Intel ® Entry Server Platform SR1325TP1-E User Guide 55 How to Obtain Warranty Service To obtain warranty service for this Product, you ma y contact Intel or your authorized distributor. North America and Latin America  To obtain warranty repair for the product, please go to the following Web site to obtain instructions: http://support[...]