Ingersoll-Rand PD15X-XXX-XXX manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PD15X-XXX-XXX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PD15X-XXX-XXX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PD15X-XXX-XXX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ingersoll-Rand PD15X-XXX-XXX should contain:
- informations concerning technical data of Ingersoll-Rand PD15X-XXX-XXX
- name of the manufacturer and a year of construction of the Ingersoll-Rand PD15X-XXX-XXX item
- rules of operation, control and maintenance of the Ingersoll-Rand PD15X-XXX-XXX item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PD15X-XXX-XXX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PD15X-XXX-XXX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PD15X-XXX-XXX.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PD15X-XXX-XXX item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    E 2010 CCN 15197213  (800) 495-0276 D F AX (800) 892-6276 INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET - - BRY AN, OHIO 43506 1 - 1/2” DIAPHRAGM PUMP OPERA T OR’S MANUAL PD15X - XXX - XXX RE LE A SE D: 8 -7 -0 3 REVISED: 5-12-10 (REV . 16 ) INCLUDING: OPERA TION, INST ALLA TION & MAINTENANCE 1:1 RA TIO (MET ALLIC) READ THIS MANUAL [...]

  • Page 2

    PD15X-XXX-XXX (en) Page 2 of 8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND, AND FOLLOW THIS INFORMA TION TO A VOID INJURY AND PROPERTY DAMAGE. EXCESSIVE AIR PRESSURE ST A TIC SPARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EXCESSIVE AIR PRESSURE. Can cause person - al injury , pump damage or property damage. S Do not exceed the maxim[...]

  • Page 3

    Page 3 of 8 PD15X -XXX-XXX ( en) GENERAL DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / fluid sections. Air operated double diaphragm pumps utilize[...]

  • Page 4

    MA TERIAL CODE [A] = Aluminum [B] = Nitrile [C] = Carbon Steel [CI] = Cast Iron [Co] = Copper [E] = E.P .R. [H] = Hytrel [Ha] = Hastelloy-C [K] = Kynar R PVDF [MSp] = M edical Grade Santoprene [P] = Polypropylene [SH] = Hard Stainless Steel [Sp] = Santoprene [SS] = Stainless Steel [T] = PTFE [V] = Viton PD15X-XXX-XXX (en) Page 4 of 8 P ARTS LIST / [...]

  • Page 5

    Page 5 of 8 PD15X -XXX-XXX ( en) P ARTS LIST / PX15X -XXX-XXX FLUID SECTION COLOR CODE 15 FOR THE AIR MOTOR SECTION SEE P AGES 6 & 7 Santoprene 8 PTFE 7 131 , x 175 k Figure 2 View of two piece PTFE diaphragm 29 , 144 k 70 k . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. (14) screw , tighten to 50 - 55 f[...]

  • Page 6

    PD15X-XXX-XXX (en) Page 6 of 8 P ARTS LIST / PX15X -XXX-XXX AIR SECTION n Indicates parts included in 637389 Air Section Service Kit shown below and items (70), (144), (175) and (180) shown on page 4. AIR MOTOR P ARTS Item Description (size) Qty Part No. [Mtl] Item Description (size) Qty Part No. [Mtl] 101 Center Body (PX15A -X) (1) 95888 [A] (PX15[...]

  • Page 7

    Page 7 of 8 PD15X -XXX-XXX ( en) P ARTS LIST / PX15X -XXX-XXX AIR SECTION 168 k . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. PX15A -XXX-XXX and PX15S -XXX-XXX: T orque (105 and 134) screws to 40 - 50 in. lbs (4.5 - 5.6 Nm). PX15R -XXX-XXX: T orque (134) screw to 30 - 40 in. lbs (3.4 - 4.5 Nm) and (236) nut[...]

  • Page 8

    PD15X-XXX-XXX (en) Page 8 of 8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of (14) diaphragm screw . Air bubbles in product discharge. S Check connections of suction plumbing. S Check “O” rings between intake manifold and inlet side fluid caps. S Check tightness of (14) diaphragm scr[...]