Hubbell Electric Heater Company 238-44422-00L manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hubbell Electric Heater Company 238-44422-00L, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hubbell Electric Heater Company 238-44422-00L one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hubbell Electric Heater Company 238-44422-00L. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hubbell Electric Heater Company 238-44422-00L should contain:
- informations concerning technical data of Hubbell Electric Heater Company 238-44422-00L
- name of the manufacturer and a year of construction of the Hubbell Electric Heater Company 238-44422-00L item
- rules of operation, control and maintenance of the Hubbell Electric Heater Company 238-44422-00L item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hubbell Electric Heater Company 238-44422-00L alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hubbell Electric Heater Company 238-44422-00L, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hubbell Electric Heater Company service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hubbell Electric Heater Company 238-44422-00L.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hubbell Electric Heater Company 238-44422-00L item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    238-44422-00L REV 3/12 ELECTRIC WATER HEATER THE WARRANTY ON THIS WATER HEATER IS IN EFFECT ONLY WHEN THE WATER HEATER IS INSTALLED AND OPERATED IN ACCORDANCE WITH LOCAL CODES AND THESE INSTRUCTIONS. THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGE RESULTING FROM FAILURE TO COMPLY WITH THESE INSTRUCTIONS. READ THESE INSTRUCTIONS TH[...]

  • Page 2

    2 TABLE OF CONTENTS General Info rmation ........................................................ 3 Installati on ....................................................................... 4 Locating The Wate r Heater ......................................... 4 Water Connect ions ...................................................... 6 Electrical Conn[...]

  • Page 3

    3 GENERAL INFORMATION This electric water heater’s design is certified by INTERTEK (ETL) and listed in accordance with UL 174. CETL listed in accordance with Canadian National Standard C22.2, No. 110-M90. Water heaters with a capacity of 19 gallons through 119 gallons are evaluated by INTERTEK in accordanc e with Part 280.707(d) (1) of HUD Mobile[...]

  • Page 4

    4 General Information continued- A sacrificial anode is used to extend tank life. Removal of this anode, for any reason, will nullify the warranty. In ar eas where water is unusually active, an odor may occur at the hot water faucet due to a reaction between the sacrificial anode and impurities in the water. If this should happen, an alternative an[...]

  • Page 5

    5 Locating The Water Hea ter continued- DO NOT locate the w ater heater w here water lines could be subjected to freezing temperatures. Locate the w ater heater so that access panels and drain valves are accessible. Some models are not equipped with a drain valve. For those models, inst all a drain tee in the cold water inlet as close as practical [...]

  • Page 6

    6 Water Connections NOTE: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting the main water supply valve, open a faucet to relieve the water line pressure to prevent any water from leaking out of the pipes while making the water connections to the water heater. After the pressure has been relieved, close the [...]

  • Page 7

    7 Water Connections continue d- WARNING For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of product[...]

  • Page 8

    8 Water Connections continue d- WARNING Hydrogen gas can be produced in a hot water system served by this w ater heater that has not been used for a long period of time (generally two w eeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot w ater faucet be opened for [...]

  • Page 9

    9 Water Connections continue d- This water heater can deliver scalding te mperature water at any faucet in the system. Be careful whenever using hot water to avoid scalding injury. Certain appliances, such as dishwashers and automatic clothes washers, may require increased temperature water. By setting the thermostat on this water heater to obtain [...]

  • Page 10

    10 Water Connections continue d- Upright Models (See Figures 1A & 1B) The hot and cold water connections are identified on the top of the water heater (See figure 1A). For bottom inlet models (-503 models), the cold water inlet is located on the side of the drain valve (see figure 1B). Connect the hot and cold water lines to the installed nippl[...]

  • Page 11

    11 Water Connections continue d- Utility Models (See Figure 2) All utility models are supplied with inlet and outlet nipples located in a plastic bag attached to the water heater. The hot and cold water locations are identified on the side of the water heater. Apply appropriate amount of thread sealant to the provided nipples and install nipples in[...]

  • Page 12

    12 Water Connections continue d- Table Top Models (See Figure 3) The hot water outlet and cold water inlet are identified on the back panel of the water heater. Referring to figure 3, remove the two screws that are holdi ng the service access panel in place. Remove front panel for access. Wedge a flat bladed screwdriver into the front joint between[...]

  • Page 13

    13 Electrical Connections Before any electrical connections are made, be sure that the water heater is full of water and that the manual shut-off valve in the cold water supply line is open. Check the rating plate and wiring diagram before proceeding. This electric water heater was built and wired in accordance with the INTERTEK testing approvals r[...]

  • Page 14

    14 GENERAL OPERATION When the switch is closed, the operati on of this electric water heater is automatic. The thermostats are preset to the “HOT” setting to provide a water temperature of approximately 120°F (49°C) to reduce the risk of scald injury. Care must be taken whenever using hot water to avoid scalding injury. Certain appliances req[...]

  • Page 15

    15 Thermostat Adjustment The temperature of the water can be c hanged by adjusting the thermostat(s). Before any work is done on the wate r heater, disconnect all power to the water heater by opening the switch at the main electrical circuit breaker or fuse box. Remove the access panels or front panel on table tops, fold the insulation outward away[...]

  • Page 16

    16 MAINTENANCE Shut off the electric power whenever t he water supply to the water heater is off. Shut off the electric power and water supply, drain the water heater completely to prevent freezing w henever the building is left unoccupied during the cold weather months. In order to insure efficient operation and long tank life, drain the water hea[...]

  • Page 17

    17 Maintenance c ontinued- 3. At least once a year, check the combination temperature and pressure relief valve to insure that the valv e has not become encrusted with lime. Lift the lever at the top of the tem perature-pressure relief valve several times until the valve seats properly without leaking and operates freely. 4. If the combination temp[...]

  • Page 18

    18 Maintenance continue d- Contact your local plumbing supplier or plumbing professional for replacement parts or contact the company at the address displayed on the rating plate of the water heater. For faster and better service, pleas e provide the part name, model, and serial number(s) of the water heater(s) when ordering parts. READ THE WARRANT[...]

  • Page 19

    19 NOTES[...]

  • Page 20

    20 NOTES[...]