HP (Hewlett-Packard) H4H3 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of HP (Hewlett-Packard) H4H3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of HP (Hewlett-Packard) H4H3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of HP (Hewlett-Packard) H4H3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of HP (Hewlett-Packard) H4H3 should contain:
- informations concerning technical data of HP (Hewlett-Packard) H4H3
- name of the manufacturer and a year of construction of the HP (Hewlett-Packard) H4H3 item
- rules of operation, control and maintenance of the HP (Hewlett-Packard) H4H3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of HP (Hewlett-Packard) H4H3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of HP (Hewlett-Packard) H4H3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the HP (Hewlett-Packard) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of HP (Hewlett-Packard) H4H3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the HP (Hewlett-Packard) H4H3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    506 01 5102 00 March 2008 INST ALLA TION INSTRUCTIONS 3-Phase R-410A Split System Heat Pump Product Fam ily: H4H3 These instructions must be read and understood completely before attempting installation. DANGER, W ARNING, CAUTION, and NOTE The signal words DANGER, W ARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The si[...]

  • Page 2

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 2 506 01 5102 00 INSPECT NEW UNIT After uncrating unit, inspect thoroughly for hidden damage. If damage is found, notify the transportation company immediately and file a concealed damage claim. SAFETY CONSIDERA TIONS Consult a qualified installer , service agency , or the dealer/dis[...]

  • Page 3

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 506 01 5102 00 3 Figure 1 Clearances (various examples) W all 6” 24” Service W all W all W all 6” 6” Post W all W all 18” 18” 18” 18” 6” 6” 6” 18” 18” 18” 18” 24” Service 24” Service 24” Service 24” Service 24” Service 24” Service 4” 4” w[...]

  • Page 4

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 4 506 01 5102 00 UNIT SUPPORT NOTE: Unit must be level  2 degrees (  inch rise or fall per foot of run) or compressor may not function properly . A. GROUND LEVEL INST ALLA TION The unit must be lev el and support ed above grade by beams, platfor m, or a pad. Platfor m or pad ca[...]

  • Page 5

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 506 01 5102 00 5 REFRIGERA TION SYSTEM A. COMPONENT MA TCHES Check to see that the proper system components are in place, especially the indoor coil. R-410A outdoor units can only be used with R-410A specific indoor coils. If there is a refrigerant mis-match, consult the indoor coil [...]

  • Page 6

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 6 506 01 5102 00 transmission between the tubing and the foundation or wall. Along floor or ceiling joists, suspend refrigerant lines so that they do not contact the building structure, water pipes, or ductwork. Use insulated or suspension type hangers. Metal straps must be at least [...]

  • Page 7

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 506 01 5102 00 7 F . SERVICE V AL VES Service valves are closed and plugged from the factory . Outdoor units are shipped with a refrigerant charge sealed i n the unit. Leave the service valves closed until al l other refrigerant system work is complete or the charge will b e lost. Le[...]

  • Page 8

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 8 506 01 5102 00 Figure 7 Deep V acuum Gauge Response and System Conditions 500 MINUTES 01 24 6 1000 1500 LEAK IN SYSTEM V ACUUM TIGHT T OO WET TIGHT DRY SYSTEM 2000 MICRONS 2500 3000 3500 4000 4500 5000 37 5 T riple Evacuation Method The triple evacuation method should only be used [...]

  • Page 9

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 506 01 5102 00 9 ELECTRICAL WIRING ! W ARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in per‐ sonal injury or death. Before installing, modifying or servicing system, turn OFF the main (remote) electrical disconnect device. There may be more than one dis[...]

  • Page 10

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 10 506 01 5102 00 Figure 1 1 T ypical Thermostat (Control Circuit) Connections LEGEND 24-V FACTORY WIRING 24-V FIELD WIRING FIELD SPLICE CONNECTION OUTDOOR THERMOST A T EMERGENCY HEA T RELA Y SUPPLEMENT AL HEA T RELA Y SHR EHR C W 2 L G Y E O R C W 2 L G Y E O R ODT EHR ODT ODT[...]

  • Page 11

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 506 01 5102 00 11 DEFROST SYSTEM A. DEFROST THERMOST A T The defrost thermostat is factory installed on a short tube stub extending from the coil end plate. Refer to Figure 12 and confirm that the thermostat is securely fastened in place on the tube stub. Figure 12 Defrost Thermostat[...]

  • Page 12

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 12 506 01 5102 00 ST ART-UP PROCEDURE 1. Set indoor thermostat selector switch to OFF . 2. T urn ON all electrical disconnect devices. 3. I f unit has a crankcase heater , energize the heater and wait 24 hours before proceeding. 4. Set indoor thermostat at desired temperature. Be sur[...]

  • Page 13

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 506 01 5102 00 13 Figure 14 R-410A Required Liquid Line T emperature ( ° F) - Cooling Mode Measured Liquid Pressure (psig) Rating Plate (required) Subcooling T emperature ( ° F) Measured Liquid Pressure (psig) Rating Plate (required) Subcooling T emperature ( ° F) 6 8 10 12 14 16 [...]

  • Page 14

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 14 506 01 5102 00 TROUBLESHOOTING Some models are factory equipped with the Comfort Alert t Diagnostics device in the control box (refer to Figure 15). Comfort Alert provides around-the-clock monitoring for common electrical problems, compressor defects, and broad system faults. If t[...]

  • Page 15

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 506 01 5102 00 15 Figure 16 Comfort Alert t Diagnostics (some models) Status LED Status LED Description Status LED T roubleshooting Information Green “POWER” Module has power Supply voltage is present at module terminals Red “TRIP” LED On Solid Thermostat demand signal Y1 is [...]

  • Page 16

    INST ALLA TION INSTRUCTIONS 3-phase R-410A Split System Heat Pump 16 506 01 5102 00 Figure 17 Comfort Alert t Diagnostics (some models) Miswired Module Indication T roubleshooting Information Green LED is not on, module does not power up Determine if both R and C module terminals are connected. V erify voltage is present at module' s R and C t[...]