Honeywell VISTA-250FBP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell VISTA-250FBP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell VISTA-250FBP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell VISTA-250FBP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell VISTA-250FBP should contain:
- informations concerning technical data of Honeywell VISTA-250FBP
- name of the manufacturer and a year of construction of the Honeywell VISTA-250FBP item
- rules of operation, control and maintenance of the Honeywell VISTA-250FBP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell VISTA-250FBP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell VISTA-250FBP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell VISTA-250FBP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell VISTA-250FBP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    K0377V2 7/ 09 Rev. B VISTA-128FBP VISTA-250FBP Commercia l Fire and Burglar y Partitio ned S ecurity Syst ems wi th Schedu ling User Guide[...]

  • Page 2

    – 2 –[...]

  • Page 3

    – 3 – TABLE OF CONTENTS SYSTEM OVERVIE W ............................ 5 General ....................................................... 5 A Partit ioned S ystem .................................. 5 Zones .......................................................... 6 Fire Protec tion ............................................6 Burglar y Protecti[...]

  • Page 4

    – 4 – PANIC KEYS ....................................... 43 Using Panic Keys ..................................... 43 REL AY CON TROL ............................... 44 General Inf orm ation .................................. 44 Executing .................................................. 44 USIN G #70 REL AY M ENU MOD E ....... 45 General Inf [...]

  • Page 5

    – 5 – System Overv iew General Congratula tions on your ownership of a Honeywell pa rtitioned Securit y Syst em. You've made a wise decis ion in choosi ng it, for it repres ents the latest in se curity pro tection te chnolo gy today . Honeywe ll is the wo rld's largest manuf acturer o f security sy stems an d millions of premises are [...]

  • Page 6

    – 6 – System Overview (cont ’ d) Zones Your sy stem' s sensing dev ices hav e bee n assigne d to va rious "zo nes." Fo r example, t he sensing de vice on your Entry/Exi t door ma y have been a ssigned to zone 001, sensing d evices o n windo ws in the master bedro om to zon e 002, and so o n. These n umber s will app ear on the [...]

  • Page 7

    – 7 – System Overview (cont ’ d) Carbon Monoxide Protection Carbon m onoxide (C O) prot ection is availa ble wit h your system using the 580 0CO Carbon Monox ide Detec tor. The 5800C O is a 3V bat tery pow ered wireles s Carbon Monoxide D etect or used w ith w ireles s alarm system s that sup port 5800 ser ies devices. Car bon monox ide g as [...]

  • Page 8

    – 8 – System Overview (cont ’ d) Device Timers The sys tem provides up to 2 0 "timers" that can be used t o control various devices, s uch as light s or applia nces. These t imers are si milar in concept t o the indiv idual appli ance timers that mig ht be pu rchased at a d epartment store. T he devices th at can be control led are [...]

  • Page 9

    – 9 – System Overview (cont ’ d) Self-Help Featur e Abbreviated user in struct ions are buil t into the sy stem th at can be e asily viewed on the al pha keypad's mess age displa y screen. This feature wi ll prove particular ly useful if th is manual is no t conven iently access ible when you need to perform a s ystem procedure with whic[...]

  • Page 10

    – 10 – About The Keypads General IMPO RTANT: If the ke ypad beeps rapi dly upon ent ering the prem ises, it ind icates that an alar m has occurred dur ing your absence. LEAVE t he prem ises IMME DIATEL Y and CO NTACT THE PO LICE fr om a saf e location n earb y. Your ke ypads allo w you to contro l all system fu nction s. The key pads featu re a[...]

  • Page 11

    – 11 – Functions of the Keypad 1 4 7 2 5 8 0 3 6 9 # 6160CR2-001-V0 Primar y Fire Keyp ad 6160CR- 2 IMPOR TA NT! W hen using t he keypad to enter codes and commands, sequential key depressions must be m ade within 3 seconds of one another. If 3 seconds elapse w ithout a key depression, the entry is aborted and must be repeated from its be ginni[...]

  • Page 12

    – 12 – Functions of the Keypad (cont ’ d) 1 OFF 4 MAX 7 INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6 BYPASS 9 CHIME # ARMED READY 6160-00-001-V0 Burglar y Keypad 6160 IMPOR TA NT! W hen using t he keypad to enter codes and commands, sequential key depressions must be m ade within 3 seconds of one another. If 3 seconds elapse w ithout a key d[...]

  • Page 13

    – 13 – Functions of the Keypad (cont ’ d) ALPHA DI SPLAY WI NDOW: A 2-l ine, 32-character Liqu id Crystal D isplay (LCD). Displa ys protection poi nt identificat ion and system statu s, messa ges, and user instructions. 1 OFF : Disarms the burglary p ortion of the syste m, sile nces alar ms and audible trouble ind icators, and cl ears visual [...]

  • Page 14

    – 14 – Functions of the Keypad (cont ’ d) ✳ READY : When depressed prior t o arming the system, the keypad will display all open prot ection zo nes withi n the keypad 's home p artition. Th is key is also used to dis play all zone descript ors that have been progra mmed for your s ystem, by holding the key down f or at least 5 seco nds[...]

  • Page 15

    – 15 – Entry/Exit Delays General Information Your syst em has insta ller-programmed time del ays, k nown as exit delay and entry delay. Whenever you a rm your system, exit delay gives you time to leave through t he design ated exit door without setting off a n alarm. Exit delay be gins immediately af ter enterin g any arming command , and appli[...]

  • Page 16

    – 16 – Security Codes and Authority Levels General Information At the time o f install ation, y ou were assig ned an au thority le vel and a personal four-digit security code, known only to you and yours. The s ecurity code must be ent ered when a rming and dis arming the sys tem. The a uthority leve l defin es the sy stem fu nction s that yo u[...]

  • Page 17

    – 17 – Security Codes and Authority Levels (cont ’ d) A uthorit y Lev els Authorit y levels define the sys tem functions a particula r user can perform. Depending on t he auth ority as signed to you, t here are c ertain s ystem functions you ma y be pro hibited from performi ng. I n summary, there a re six authority levels, each having certai[...]

  • Page 18

    – 18 – Security Codes and Authority Levels (cont ’ d) General Rules on Authority Levels and Changes • A user may not delete or chan ge the user code of t he SAME or H IGHER authority than w hich he is assigned . • A user may only ADD users to a LO WER authority le vel. • A user may as sign access codes only to thos e partitions to which[...]

  • Page 19

    – 19 – Security Codes and Authority Levels (cont ’ d) To Add a User IMPORTANT: Temporary users s hould not be s hown how to use any syst em function they do not need to k now (e.g. bypas sing protecti on zones). CODE 1. Ent er Master or Manager code and press the 8 key. 2. Enter the n ew user's 3- digit Use r Number (0 02-250) . 3. Enter[...]

  • Page 20

    – 20 – Security Codes and Authority Levels (cont ’ d) MULTI-ACCESS ? 0 = NO , 1 = Y ES If you as a user have a ccess to other partitions, the keypad will promp t for abili ty of th is new user to access (GOTO) those pa rtitions . Press 0 (NO) or 1 (YES). If no, the system ac tivates th is user co de and exits “ Add a User” mode. If yes, t[...]

  • Page 21

    – 21 – Security Codes and Authority Levels (cont ’ d) To Change a User's Code CODE 1. Ent er Master or Manager code and press the 8 key + user number to be chang ed. 2. Enter the new code for th at user. ADD NEW USER? 0 = NO , 1 = Y ES The syste m will recog nize that the user numbe r is already in use and will p romp t whether o r not t[...]

  • Page 22

    – 22 – Security Codes and Authority Levels (cont ’ d) To Delete a User CODE 1. Ent er Master or Manager code and press the 8 key + user number to be de leted. 2. Enter Master or Manager code first ent ered. OK TO D ELE TE 0 = NO , 1 = Y ES The sys tem will reco gnize that the User numbe r is already in use and w ill pro mpt to conf irm that i[...]

  • Page 23

    – 23 – Accessing Other Partitions To A ccess another Partit ion Each keypad is assi gned a default partiti on for display purpos es, and will show o nly that partitio n's inf ormation. But, if the user is authorize d, a keypad in on e partiti on can be used to perform sys tem functions in other partition s by using the GOTO command. Note t[...]

  • Page 24

    – 24 – Accessing Other Partitions (cont ’ d) Global A rming Notes: • When performing a Global Arm, if th ere are faul ts in a ny of the s elected partitio ns, the sys tem wil l ente r a Summary Mode. Fau lted zone s in all the selected partitions will be displayed. These faults must be corrected or byp assed. Thi s Summa ry Mode will end in[...]

  • Page 25

    – 25 – Accessing Other Partitions (cont ’ d) The followi ng is an example of what would be displayed for a fa ult condition on Zo ne 002 (Load ing Dock Win dow) o n Partit ion 1 (Wareho use) wh en logging on from a k eypad on Pa rtition 9: W HSE DISARM ED HIT ✴ FOR FAULTS This is the normal di splay that appear s at Par tition 1's keyp[...]

  • Page 26

    – 26 – Accessing Other Partitions (cont ’ d) Common Lobby Operation When an insta llation cons ists of a partit ion that is sha red by users of other partition s in a building , th e shared partit ion may be assign ed as a “co mmon lobby” pa rtition for t he syst em. An example of this mi ght be in a medical buildi ng where there are two [...]

  • Page 27

    – 27 – Accessing Other Partitions (cont ’ d) How User Codes A ffect the Common Lobby Codes with “Global” Arming If your cod e is given “g lobal arming” w hen it is de fined, the syste m display s a prompt that allows you to pick a nd choose the parti tions to be ar med or disa rmed. This eli minates th e “automat ic” operati on of[...]

  • Page 28

    – 28 – Checking For Open Zones Using the ✴ ✴ ✴ ✴ RE ADY Key Before arming your syst em, all prot ected doors, win dows and ot her protect ion zones must b e closed or bypass ed (see BYPASSING secti on). Otherwise the keypad will displ ay a "No t Ready" messag e. Us ing the READY key wil l displa y all zones that ar e faulted, [...]

  • Page 29

    – 29 – Displaying All Zone Descriptors Using the ✳ ✳ ✳ ✳ READY Key The Alp ha Key pads can also di splay all the z one d escripto rs that ar e programme d in you r system. The abbreviate d instru ctions for the READY key will ap pear first , followe d by the zo ne descriptors. D isplay ing all descriptors is useful when you need t o kno[...]

  • Page 30

    – 30 – Bypassing Protection Zone s Using the 6 BYP A SS Key This key is used when you wa nt to arm your s ystem with one or mor e zones intenti onally unprotected. Bypass ed zones are unprotected an d will not cause an alarm when violated while y our syste m is armed. All bypasses are removed when an OF F sequence (s ecurity code pl us OFF ) is[...]

  • Page 31

    – 31 – Bypassing Protection Zone s (cont ’ d) Quick By pass Your sy stem allo ws you to easily bypass all ope n (fau lted) zo nes wi thout having to enter zone numbers individually. Note: All bypasses are removed wh en an OFF s equence (securit y code plus OFF) is performed. To us e the Qui ck Bypas s fe ature: BYPASS 1. Enter your security c[...]

  • Page 32

    – 32 – Bypassing Protection Zone s (cont ’ d) Group Bypass Your syst em allows you to eas ily bypas s a group of zones wit hout having to enter zone numbers i ndividually. The system provides up to 15 groups. There is no li mit to the number of z ones that may be assi gned to any one group. Check wit h your install er for a list of zones a ss[...]

  • Page 33

    – 33 – Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use thi s key when you a re st aying home, bu t might expect someon e to us e the entran ce door later. When arme d in S TAY mod e, the sy stem will soun d an alarm if a pro tected door or window is opened, but you may otherwise move freely through out the prem ises. Late a[...]

  • Page 34

    – 34 – Arming Perimeter Only (With Entry Dela y ON) (cont ’ d) Au t o -S T AY Ar m in g Auto-stay allows the sy stem to automa tically bypass c ertain zones if upo n arming none of the entr y/exit zones are faul ted during t he exit del ay time (n o one exits the premises ). The system provides an option to set ea ch burglary zone for Auto-st[...]

  • Page 35

    – 35 – Arming Perimeter Only (With Entr y Delay OFF) Using the 7 INSTANT Key Use thi s key when you ar e sta ying home and do not expect anyon e to use the entrance door. When armed in INSTA NT mode, th e syste m will sound an alarm if a protected door or windo w is opened, b ut you m ay otherwi se move freel y throughout t he premises. T he al[...]

  • Page 36

    – 36 – Arming All Protection (With Ent ry Delay ON) Using the 2 AW AY K e y Use this key whe n no on e will be stayin g on the premise s. When arme d in AWAY mo de, the sy stem will so und an alarm if a p rotected door or window is opened, or if any movement is det ected inside the premis es. You may leave t hrough the entra nce door during the[...]

  • Page 37

    – 37 – Arming all Protection (with Entry Delay OFF) Using the 4 MA XIMUM Key Use this ke y when the pre mises will be v acant fo r extend ed period s of time such as vac ations, e tc., or w hen no one will be movin g through protected interior area s. When arme d in MAXIM UM mode, th e system w ill soun d an alarm if a protected door or window [...]

  • Page 38

    – 38 – Quick Exit Using the # + 9 Ke y s The Quic k Exit f eatur e all ows you to exi t the arm ed par tition wi thout h avin g to disar m and then r earm th e partit ion. To Quick Ex it the premi ses: 1. Press the # key and then press t he 9 key. 2. The sy stem w ill sou nd the ex it beep s, if enabled, and w ill give y ou the prog rammed exi [...]

  • Page 39

    – 39 – Disarming and Silencing Al arms Using the 1 OFF Key The OFF key is used to di sarm the sys tem and to sil ence alarm and t rouble sound s. See Summary of Audible Notification section fo r information that will help y ou to dist inguis h betwee n FIRE and BUR GLARY al arm sounds. IMPO RTANT: If you return and the m ain burgl ary soun der [...]

  • Page 40

    – 40 – Using the Keyswitch General Your system ma y be equipped wit h a keyswi tch for use when arming and disarmi ng a partiti on. A red and green light on the keys witch pla te indicate the st atus of your sy stem as f ollows: Green Light: Lights when the s ystem is disarmed and ready to be armed (no open zon es). If the s ystem is disarmed a[...]

  • Page 41

    – 41 – Chime Mode Using the 9 Key Your syst em can be set to alert you t o the opening of a door or wi ndow while it is di sarmed by using C HIME mo de. Whe n activ ated , three tones w ill so und at the Keypa d whenever a protected peri meter door or window i s opened, and the No t Ready me ssage will be di splayed. Pressi ng the READY key w i[...]

  • Page 42

    – 42 – Viewing Alarm Company Messages General Information User s of the sy stem may periodic ally r eceiv e mes sages on their displ ay screen s from th eir moni tori ng agen cy or insta ller. When a messag e is w aitin g to be vi ew ed, the m essag e sh own b elow w ill app ear. MESSAG E. PRES S 0 FOR 5 SECS. 1. Press and h old down 0 key f or[...]

  • Page 43

    – 43 – Panic Keys (For Manually Activat ing Silent and/or Audible Alarms) Using Panic Key s Your system ma y have been programmed to use special k ey combinations to manually a ctivate panic funct ions. The funct ions that mi ght be programmed are Sil ent Emergency, Audible Emergency, and Personal Emergency. S ee your insta ller for the functi [...]

  • Page 44

    – 44 – Relay Control General Information Your syste m may be set up using a relay so that a door (such as in a lobby) can be unlocked mo mentarily using a keypad co mmand. Ask your installer i f this h as been d one in our system. Executing To acti vate the rela y enter your securit y code + [0] at the keypa d. The door will unl ock for 2 sec o[...]

  • Page 45

    – 45 – Using #70 Relay Menu Mode General Information Your system m ay be s et up so that cer tain lig hts or other d evic es can b e turned on or off by using t he #70 com mand f rom a key pad. Ask your inst aller if this has b een done in your sy stem. To activate rel ays from a keypad , enter 4-di git securi ty code + [#] +7 0. Follo w the ke[...]

  • Page 46

    – 46 – Using Schedules Delaying the Closing Time Your sy stem 's prog ramm ed sched ules m ay au tomati cally arm the sys tem a t a predet ermin ed t ime. I n the event a user must stay o n the p remi ses la ter th an usual, users with maste r or manager authority levels can manually delay the automati c arming (closing) time up to 2 hours[...]

  • Page 47

    – 47 – Using Schedules (cont ’ d) Programming Temporary Schedules Te mpor ary sc hed ules o nly af fec t the part iti on fro m wh ich it is e nter ed. Temporary schedul es can be reu sed at lat er dates simply by scrolling (by pressing # ) to the DAYS? prompt (described belo w) and activati ng the appropriate da ys. This shoul d be considered[...]

  • Page 48

    – 48 – Using Schedules (cont ’ d) DAYS ? MTW TF SS HIT 0-7 X X This is the prom pt tha t actu ally activ ates th e temp orary schedul e, and allow s the t empor ary schedule t o be cust omized to a part icular week's need s. To select the d ays that are to be activ ated, enter th e d esired n umber 1-7 (M onday = 1). An "X" wil[...]

  • Page 49

    – 49 – Programming Device Timers General Information D e v i c e t i m e r s c o n s i s t o f a n O N t i m e a n d a n O F F t i m e , a n d s e l e c t e d d a y s o f the week in which they are ac tive. T here are up to 20 ti mers that can be used to control various devices, such as lights or appliances. Your installer will have programmed [...]

  • Page 50

    – 50 – Programming Device Timers (cont ’ d) 00 ON T IME ? 00:00 PM Enter th e time y ou want the devic e turned on usi ng 00: 01 - 11 :59 f ormat . When the dis pla y show s the de sired time, p ress the * ke y to mo ve to the AM/P M field. Pre ss any key 0-9 to ch ange the AM/ PM indica tion. Enter 00: 00 if this timer i s not being used to [...]

  • Page 51

    – 51 – Programming Device Timers (cont ’ d) Randomize Output Device Times Dev ices in yo ur syste m may be set for a random sche dule, w hereby th ey will turn on and off at differ ent ti mes each day. This is us eful when going on vacati on and you desire t he turni ng on and of f of t he lights to the give t he appearance of s omeone being [...]

  • Page 52

    – 52 – Using #77 Instant Activation Mode The #77 Ins tant Activa tion Mode is use d to activat e outpu ts, bypass zon es, etc. immedi ately upon exit ing the #77 Mode. The acti ons that may be activated are relay command s, arm/disarm co mmands, zone bypassing comman ds, and op en/clo se acce ss condi tions. Relay Commands Action Code Action Sp[...]

  • Page 53

    – 53 – Using #77 Instant Activation Mode (cont ’ d) Bypass Commands Activatio n times 1 (Beginning), 2 (End), and 3 (During ) are the o nly valid choices for bypass commands. If 3 (Dur ing) is selecte d for auto -bypassing , the sys tem bypass es the zone(s) s pecified on a part icular zone l ist a t the beginning of the wind ow and unbypa ss[...]

  • Page 54

    – 54 – Using #77 Instant Activation Mode (cont ’ d) A dditional Commands Action Code Action Specifier 77 Access Po int Group Enabl e Group # 78 Access Po int Grou p Disabl e Group # To enter the Instant Activation M ode: Enter your securit y code; then press the [#] key foll owed by 77. ACTIO N ? Enter the code for the desire d action. The ac[...]

  • Page 55

    – 55 – Event Log Procedures General Information The syst em has the ab ility t o record various event s in a history log wherei n each event is recorded in one of five catego ries (li sted below ), w ith the time and date of it s occurrence. The Event Log holds up to 1000 e vents, w ith the olde st event being re placed by th e logging of any n[...]

  • Page 56

    – 56 – Event Logging Procedures (continued) 4. Use the [3] an d [1] key s (for next and previous categories respecti vely) to displa y the categories of events. Press [8] to select a category and displa y the first event. Press [8] agai n for each subs equent event. Shows burglary alarm occurred in zone 3 (C03) of partition 1 (P1) , at 12:02A M[...]

  • Page 57

    – 57 – Testing the System (To Be Conducted W eekly) Using the 5 TEST Key The TEST key puts y our syste m into Bu rglary Walk Te st mode , which allow s each burglary prot ection point to b e checked for proper op eration. 1. Disa rm the sys tem and close all protected windo ws, doors, etc. READ Y should be displa yed. TEST 2. Ent er your securi[...]

  • Page 58

    – 58 – Fire Alarm System Your fire alarm system (if in stalled) is on 24 hou rs a day, pro viding continuous prot ection. In the event of a n emergency, the sm oke and heat detectors a utomatically send si gnals to your C ontrol, tri ggering a loud interrupti ng sound from t he keypad and the opti onal exterior s ounders. FIRE appear s at yo ur[...]

  • Page 59

    – 59 – Fire Alarm System (cont ’ d) Event Display Lock If several zones produce an alarm, trouble or supervisory, the system wil l displa y the first zone that produced a n event. T o dis play the ot her zone(s) in alarm or t rouble, pres s the [*] key for each zone. Fire Drill Test (Code + # + 69) This te st causes N otific ation Applian ce [...]

  • Page 60

    – 60 – Trouble Conditions Typical Trouble Displ ays The w ord CHECK or TRBL on the K eypad's disp lay, accomp anied by a rapid "beeping" at the Keypa d, indicat es there is a troub le condition in th e system. To silence the beep ing sound for troubl e conditions, press any key. • “CHECK” or “TRBL” display acco mpanie d[...]

  • Page 61

    – 61 – Trouble Conditions (cont ’ d) • A display of " COMM. FAILURE " at the Keypad indicates that a fai lure has occurred in t he telephone communication po rtion of your sys tem. CALL FOR SERVICE I MMEDIATELY. • A display of " SYST EM LO BAT ", accompanied by a once per minu te "beepin g" at the K eypad ind[...]

  • Page 62

    – 62 – Emergency Evacuation Estab lish and regula rly practice a pl an of escape in the event of fire. Th e following steps are recommended by the Na tional Fi re Protection Ass ociation: 1. Position your det ector or your int erior and/or exter ior sounders s o that they can be heard by al l occupants. 2. Determine two mea ns of escape from ea[...]

  • Page 63

    – 63 – Maintaining Your System Taking Care of Your Sy stem The components of your securi ty system are des igned to be as free of maintenanc e as poss ible. Ho wever, th ere are so me things y ou can do to make sure that your system is in reliable working condition. 1. Test your system weekl y. (See TESTING THE SYSTE M and FIR E ALARM SYST EM s[...]

  • Page 64

    – 64 – Maintaining Your System (cont ’ d) Silencing Low Battery Warning Tones at the Keypad The key pad’s w arning ton es can be sile nced by perfor ming an OF F seque nce (code plus OFF key) , but the K eypad 's low ba ttery message d isplay will remain on as a re minder that you have a low battery condition in one or more of your sen[...]

  • Page 65

    – 65 – Quick Guide to Fire System Functions ACT ION PROCEDURE Displaying Ev ent The system is progra mmed to loc k the keypad d isplay with the f irst event th at occurred in pr iority order. 1. Fire – highes t priority 2. Life Safety 3. Troubles and Superv isory 4. System Event s (i.e. low battery ) – lowest pri ority To display the nex t [...]

  • Page 66

    – 66 – Quick Guide to Burglary System Functions FUNCTION PROCEDURE COMMENTS Check Zon es Press [ ✱ ]. To view faulted zone s when is system not ready Display All Descrip tors Press and hold [ ✱ ] for 5 sec onds. Displays al l alpha de scriptor s programmed by install er. Arm System Enter code. Press arming key desire d (AWAY, STAY, INSTANT,[...]

  • Page 67

    – 67 – Quick Guide to Burglary System Functions (cont ’ d) FUNCTION PROCEDURE COMMENTS Delete a User Enter master/manag er code. Press CODE [8]. Enter user no. to be deleted. Enter master/m anager code. Press 1 (Y es) at prompt. Master and M anager lev el user s can delet e users. A user can on ly be de leted by a user with higher aut hority [...]

  • Page 68

    – 68 – Summary of Audible Notifica tion (Alpha Display Keypads) SOUND CAUSE DISPL A Y LOUD, INTERRUP TED* Keypad & External FIRE AL ARM FIRE is displayed; descriptor of zone in alarm is displayed. LOUD, CONTINUOUS* Keypad & External BURGLARY/ AUDIBLE EME RGENCY ALARM AL AR M i s displayed; descript or of zone in alarm is also displayed.[...]

  • Page 69

    – 69 – FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not m ake any change s or mo dificat ions to the equipment un less authorized b y the Instal lation Instructions or User's Manual. Unauthor ized changes or modifications coul d void the user's author ity to operate the eq uipment . FCC CLASS B STATEMENT This equ ipment[...]

  • Page 70

    – 70 – “ FEDERAL COMM UNICATIONS COMMISSION (FCC) Part 68 NOTICE This equipm ent com plies with Part 68 of the FCC r ules. On the f ront cover of this equipm ent is a label that c ontains , among other inform ation, the FCC registrat ion num ber and ringer equivalenc e number (REN) f or this e quipm ent. If reques ted, this inform ation m ust[...]

  • Page 71

    – 71 – CANADIAN DEP ARTMENT OF COMMUNIC A TIONS (DOC ) ST A TEM ENT NOTICE The Canadian Departm ent of Communications label identifi es certified equipment. This cert ification means that the equi pment meets certai n telecommunications network protect ive, operational and safety requirements . The Department does not guarantee the equipment wi[...]

  • Page 72

    – 72 – WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While t his system is an advanc ed design sec urity system, i t does not offer guarant eed protecti on against burglary or f ire or other em ergency. Any alarm system, whether commercial or res idential, is s ubject to compromise or fai lure to warn for a variety of reas ons. For example: •[...]

  • Page 73

    – 73 – Index #70 comm and ......................................... 45 AC Loss .................................................. 61 Access Anothe r Partit ion .................... 23 Access Control Comm ands .................... 53 Action Code .......................................... 52 Action Specifier .................................... 5[...]

  • Page 74

    – 74 – Maxim um ............................................ 6, 23 MAXIMUM .............................................. 15 MAXIMUM m ode .................................... 37 Mem o r y of A la r m .............................. 7, 39 Messages ............................................... 42 Modem Com m ....................................[...]

  • Page 75

    TW O YE A R LI MI TED W A RR ANTY Honeywell Internat ional Inc., act ing through its Security & Communications business (“S eller”), 2 Corporate Center Dri ve, Melville, New York 11747 warrant s its products to be f ree from defects in mat erials and workmanship under normal us e and service, normal wear and t ear excepted, for 24 m onths f[...]

  • Page 76

    NOTES[...]

  • Page 77

    NOTES[...]

  • Page 78

    NOTES[...]

  • Page 79

    NOTES[...]

  • Page 80

    2 Corporate Center Drive, Suite 100 P .O . Bo x 9040, Melville, NY 11747 Copyright © 2009 Honeywell International Inc. www .honeywell.com/security ÊK0377V 2eŠ K0377V2 7/09 Rev . B[...]