Honeywell Switches manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell Switches, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell Switches one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell Switches. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell Switches should contain:
- informations concerning technical data of Honeywell Switches
- name of the manufacturer and a year of construction of the Honeywell Switches item
- rules of operation, control and maintenance of the Honeywell Switches item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell Switches alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell Switches, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell Switches.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell Switches item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Sensing and Control[...]

  • Page 2

    2 SWITCH APPLICA TIONS CONTENTS • Ultra Duty P ressure Switches 10-400 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.3 • Extended Duty P ressure Switches 0.5-150 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.4 • Extended Duty V acuum Switches1.1-22” Hg . . . . . . . . . . . . . . . . . . . .[...]

  • Page 3

    5000 Series Ultra Duty 2 T erminals Metri-Pack Integral Connector Pressure Switches (See Note 1) Contact Factory Circuitry Screw Blade Contact Factory Circuitry Part # Setting Set At Part # Part # Setting Set At N.O . 83298 83313 N .O. 83328 10-35 PSI 20 PSI N .C. 83299 83314 10-30 PSI 20 PSI N .C. 83329 ±4 psi ± 4 psi DC* 83300 83315 DC* 83330 N[...]

  • Page 4

    1.47” REF . The 5000 Series switch is specifically designed to stand up to extended duty applications. This switch is factory set but capable of field adjustment. It features a Kapton diaphragm for compatibility with a wide variety of fluids, and various terminations including a Metri-P ack connector that forms a tight seal when connected. Among [...]

  • Page 5

    5 Single Circuit 1 T erminal 3. The tolerances given in the table are applicable to a switch adjusted so that the N .O . circuit closes before the N .C. circuit opens and applies to the N .C. circuit. The N .O . set point and tolerances are such that a minimum overlap of 1 PSI exists during which both circuits are on. 5000 Series Pr essur e Switch [...]

  • Page 6

    6 Set Points fr om 1.1” to 22” Hg 5000 Series Extended Duty V acuum Switches W ith Direct Action Blade Contacts 5000 Series V acuum Switch Circuitry Contact Setting P art Number Internally Grounded T wo T erminals P art Number 1.1-22” Hg N.O . N .C. 78813 78815 78814 78816 Screw Blade Screw Blade 77342 77343 77344 77345 Standard set points ar[...]

  • Page 7

    7 The 5000 Series piston switch is specifically designed for extended duty applications with set point requirements from 200 to 1000 PSI. This switch is factory set with various terminations available including a Metri-P ack connector that forms a tight seal when connected. Among the outstanding design benefits are its durable construction, compact[...]

  • Page 8

    8 Set Points fr om 2 to 70 psi and 2” to 22” Hg Series III Factory Set V ariable Dif fer ential Pr essure & V acuum Switches With Snap Action Contacts The Series III switch is a customizable switch built per customer specifications. It features a non-ferrous chamber and excellent set point integrity at extreme temperatures. The exclusive sn[...]

  • Page 9

    9 Set Points fr om 35 to 3000 psi Series V High Pr essure Environmentally Sealed, Extreme-Duty Switches With Snap Action Contacts 1.187” REF . 1.187” REF . Diaphragm T ype Set P oint Range Differential 26900 26901 26902 26903 35-50 PSI 50-100 PSI 100-200 PSI 200-300 PSI 10-15 PSI 10-15 PSI 10-15 PSI 10-20 PSI Reference Number Piston T ype Set P[...]

  • Page 10

    Pressure/V acuum Switch - A device that senses a change in pressure/ vacuum and opens or closes an electrical circuit when the set point is reached. Set P oint - The pre- determined pressure/vacuum value that is required to open or close the electrical contacts in the switch. Electrical Contacts - The elements in the switch that electrically respon[...]

  • Page 11

    It is the goal of Honeywell to meet customer value -needs through continuously improved products and processes. That is the basis by which we work to create a partnership with our customers. Evidence of our commitment is proven by a goal of a Shipped P roduct Quality Level (SPQL) of 100 ppm. W e utilize Advanced Quality Planning, and a QS9000 based[...]

  • Page 12

    Sensing and Control Honeywell P .O. Box 19424 Springfield, IL 62794-9424 USA email: www .honeywellhobbs.marketing@honeywell.com www .honeywell.com/hobbs Catalog 10-1003, GLO Printed in the U.S.A. © 2004 H oneywell International Inc. All Rights R eserved. W arranty/Remedy Hone yw ell w arrants goods of its manuf actur e as being free of def ectiv e[...]