The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell Series 4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell Series 4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell Series 4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell Series 4 should contain:
- informations concerning technical data of Honeywell Series 4
- name of the manufacturer and a year of construction of the Honeywell Series 4 item
- rules of operation, control and maintenance of the Honeywell Series 4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell Series 4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell Series 4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell Series 4.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell Series 4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part number 550-141-893/0800 AHE SERIES 4 Dir ect V ent W all-Mounted Boilers User’ s Information Manual Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance . • Do not touch any electrical switch ; do not use any pho[...]

  • Page 2

    Part number 550-141-893/0800 2 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual Please read this page first Hazard definitions The follo w ing defined terms are used thr oughout this manual to bring attention to the prese nce of hazards of various risk levels or to important information co ncerning the life of the pro[...]

  • Page 3

    Part number 550-141-893/0800 3 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual Failure to adhere to the following guidelines can result in severe personal injury , death or substantial property damage. When servicing boiler • T o avoid e lectr ic shock, disconnect electrical supply befor e performing maintenanc e. [...]

  • Page 4

    Part number 550-141-893/0800 4 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual Boiler service and maintenance The U ser’ s Information M anual provides information to the boiler owner/user for ro utine oper ation and maintenance and e mergency shutdo w n. Detailed informatio n on boiler installation, operation, sta[...]

  • Page 5

    Part number 550-141-893/0800 5 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual User maintenance procedures Boiler must be serviced and maintained Component information For d e tailed illustrations showing boiler assembly parts and compon ents, re fer to the “R eplacem ent par ts” section in the AHE Se r ies 4 Boi[...]

  • Page 6

    Part number 550-141-893/0800 6 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual User maintenance procedures continued Check boiler piping Visu ally insp ect for leaks around piping, cir culators, relief valv e and other fittings. I mmediately call a qualified service technician to repair an y leaks. Check automatic ai[...]

  • Page 7

    Part number 550-141-893/0800 7 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual Main bur ner flames 1. See Figure 4. R emov e burner input plenum co ver plate “ A ” . 2. Visually inspect burner flames: • Proper main burner flame (see Figure 5): a. Y ello w-orange streaks may appear (caused by dust). • Improper[...]

  • Page 8

    Part number 550-141-893/0800 8 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual User maintenance procedures continued Operate relief valve T o avoid wate r damage or scalding due to valve operation, a me tal discharge line must be connect ed to relief valv e outlet and run to a safe plac e of disposal. This discharge [...]

  • Page 9

    Part number 550-141-893/0800 9 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual FOR YOUR SAFETY READ BEFORE OPERA TING OPERA TING INSTRUCTIONS TO TURN OFF GAS TO THE APPLIANCE • Do not tr y to light any appliance. • Do not touch an y electric sw itch; do not use any p hone in your building. • Immediately call yo[...]

  • Page 10

    Part number 550-141-893/0800 10 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual Honeywell VR8205 and White-Rodgers 36E gas valves FOR YOUR SAFETY READ BEFORE OPERA TING OPERA TING INSTRUCTIONS TO TURN OFF GAS TO THE APPLIANCE • Do not tr y to light any appliance. • Do not touch an y electr ic switch; do not use a[...]

  • Page 11

    Part number 550-141-893/0800 11 AHE Series 4 Direct V ent Wall-Mounted Boilers — User’ s Information Manual Common problems and solutions Symptom Common Causes Possible Corrections Rapid cycling — boiler turns on and off frequently Thermostat installed where drafts or heat affect reading Locate thermostat on inner wall away from heat sources [...]

  • Page 12

    12 Part number 550-141-893/0800 W eil-McLain 500 Blaine Street Michigan City , IN 46360-2388 http://www .weil-mclain.com A United Dominion Compan y W eil-McLain Limited W arranty for Residential & Commercial Cast Iron Boilers RESIDENTIAL W A TER W ARRANTY—Limited Lifetime RESIDENTIAL STEAM W ARRANTY—Limited 10 Y ear COMMERCIAL W ARRANTY—L[...]