Honeywell CT1802 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell CT1802, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell CT1802 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell CT1802. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell CT1802 should contain:
- informations concerning technical data of Honeywell CT1802
- name of the manufacturer and a year of construction of the Honeywell CT1802 item
- rules of operation, control and maintenance of the Honeywell CT1802 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell CT1802 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell CT1802, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell CT1802.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell CT1802 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 69-0394—3 D. F. • Rev . 11-96 • Printed in U.S .A. • • ©Honeywell Inc. 1996 • Form Number 69-0394—3 Installation Instructions CT1800 24V gas or oil heat, or 3 wire zone v alves. CT1801 24V gas or oil heat/cool. CT1802 24V central electric heat/cool or single stage heat pump without auxiliary heat. Not for use on line v oltage (120V[...]

  • Page 2

    69-0394—3 2 T ABLE 1—THERMOST A T AND SUBBASE APPLICA TIONS. a 1 PREP ARA TION Check thermostat and wallplate suitability f or your heating or heating/cooling system. Refer to T able 1. Assemble tools as required. FLAT BLADE SCREWDRIVER HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED TO DRILL HOLES IN WALL WIRE CUTTER/STRIPPER OR SHARP [...]

  • Page 3

    3 69-0394—3 M6115 BULB SWITCH ANTICIPATOR SCALE ANTICIPATOR SETTING LEVER Disconnect wires from old thermostat, wallplate or subbase. T ape each end and label with the letter of the terminal designation to make reconnection easier . If there are only two wires labeling is not necessary . IMPORT ANT : If old thermostat has B or O terminals, this t[...]

  • Page 4

    69-0394—3 4 3 SCREW HOLES WITH PLASTIC ANCHORS HEATING-ONLY WALLPLATE M9612 AUTO OFF COOL HEAT ON FAN B O W Y R G M2419 SPIRIT LEVEL 5 WIRE W ALLPLA TE OR SUBBASE NO TE: All wiring must comply with local electrical codes and ordinances. Refer to illustr ation and strip ther mostat wire insulations as necessary . BARRIER FOR WRAPAROUND CONNECTION?[...]

  • Page 5

    5 69-0394—3 AUTO OFF COOL HEAT ON FAN W Y G M2413 HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL FAN RELAY L1 (HOT) L2 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1 RC RH L1 (HOT) L2 1 1 5-WIRE SYSTEM AUTO OFF COOL HEAT ON FAN W Y G M2414 HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL FAN RELAY POWER SUPPLY[...]

  • Page 6

    69-0394—3 6 6 MOUNT THE THERMOST A T Note the tabs on the top inside edge of the thermostat b ase . These fit the slots molded into the top of the wa llplate or subbase. Hang the thermostat base on the wallplate or subbase as shown in illustration. Inser t the tw o captive mounting screws located in the bottom corners of the ther mostat base (see[...]

  • Page 7

    7 69-0394—3 8 INST ALL CLOCK BA TTERIES Po we r is supplied to the cloc k by two AAA alkaline batteries (included). Install clock batteries in thermostat as shown. Once a year , or when batteries are dead, replace with two new AAA alkaline batteries. W e recommend Energizer ® batteries. Other types of batteries are more likely to leak, which cou[...]

  • Page 8

    69-0394—3 8 69-0846 4 Helping You Control Your World Push both temperature control le vers together at least 5 ° F (3 ° C) abov e room temperature. The heat should come on. The fan will start when the fur nace heats up, Mov e both levers 5 ° F (3 ° C) below room temper ature. T he heat should shut off . Operate the entire heating system f or [...]