Honeywell CT1503 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell CT1503, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell CT1503 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell CT1503. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell CT1503 should contain:
- informations concerning technical data of Honeywell CT1503
- name of the manufacturer and a year of construction of the Honeywell CT1503 item
- rules of operation, control and maintenance of the Honeywell CT1503 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell CT1503 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell CT1503, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell CT1503.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell CT1503 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CTl500, CT1501, CT1502, CT1503 ELECTROMECHANICAL FUEL SAVER THERMOSTAT AND WALLPLATEEUBBASE CTI500-24 V gas or oil heat. CTl501-24 V gas or oil heat/cool. CTI502--24 V central electric heat/cool or single stage heat pump without auxiliary heat. CTI 503-750 millivolt heat. NOT FOR USE ON LINE VOLTAGE (120 V) SYSTEMS. INSTALLATION MANUAL Any question[...]

  • Page 2

    THERMOSTAT FEATURES I-Front of thermostat. HlGH TEMPERATURE CONTROL LEVER (RED) 1 LOW TEMPERATURE CONTROL LEVER (BLUE)- 11.711 'THERMOSTAT THERMOMETER 1 COVER Il-Hinged cover lifted. .. .~ . ,..... . "--- PROGRAM PINS A Ill-Cover removed. 24 HOUR PROGRAM DIAL ANTICIPATOR HIND THERMOSTAT. HELD ON BY TWO CAPTIVE SCREWS.) CAPTIVE MOUNTING[...]

  • Page 3

    k PREPARATION ((1 "1 THERMOSTAT MODEL CT1500 CT1501 CT1502 SUBBASE OR 199986C Wallplate Q682A1079 Subbase Q682B1227 Subbase WALLPLATE INCLUDED FOR USE WITH 2-wire, 15 to 30 volt control circuit For gas or oil heating system. 4- or 5-wire, 15 to 30 volt control circuit For gas or oil heating/cooling system. 4-wire, 15 to 30 volt control circuit[...]

  • Page 4

    If wallplate or subbase is mounted on a vertical outlet box (check old installation), order 196393A Cover Plate and Adapter Ring (see appro- priate figure under step 4). Call Honeywell Consumer Services (1 -800-468-1 502) for ordering information, Monday-Friday, 7:30 a.m. to 500 p.m. Central time. Test to make certain that your heating and cooling [...]

  • Page 5

    F REMOVE OLD THERMOSTAT 0 “3 Remove cover of old thermostat. If the cover 0 doesn’t snap off when pulled firmly from the bottom, check for a screw that locks the cover on. Before removing the old thermostat from the 0 wall, look at it carefully to locate the heat anticipator adjustment mechanism. (See illustration to help you recognize the heat[...]

  • Page 6

    b MOUNT WALLPLATE OR SUBBASE 10 “4 If mounting on outlet box, mount as shown on appropriate figure. If mounting on wall, hold wallplate or sub- base in position and mark holes on wall. Use spirit level to make sure wallplate or sub- .’ .. base will be level. Drill 3/16 in. holes and gently tap anchors into holes until flush with the wall. Posit[...]

  • Page 7

    n Carefully level the wallplate or subbase and firmly u tighten screws. .. SPIRIT LEVEL ‘‘wm WALLPLATE SCREWS “2) 5 69-0273-9[...]

  • Page 8

    WIRE WALLPLATE OR SUBBASE MOTE: All wiring must comply with local electrical Refer to illustration and strip thermostat wire insulation as necessary. codes and ordinances. 0. : F"rn ~STFldilRUT . -. . - . . .. . . CONNECTION- - FOR WRAPAROUND BARRIER CONNECTION- STRlP7116In. [11 mml For CT1500 heating-only 0 , II A POWER SUPPLY. PROVIDE DISCON[...]

  • Page 9

    For CT1501 heating/cooling Connect the wires to matching terminals on the subbase. 4-WIRE SYSTEM U U 5-WIRE SYSTEM I I I I RELAY OR CONTACTOR VALVE COIL I I 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND M2&13 NOTE: If there are four wires, connect wire marked R to terminal RH and add a jumper wire to connect to RC. If RC is left uncon- nected, t[...]

  • Page 10

    OLDSUBBASE TERMINAL R or RH RC W Y G B 0 P Push excess wire back into wall. and plug hole in wall with nonflammable insulation to prevent drafts from affecting thermostat operation. CONTROL FUNCTION Heating transformer power to control circuit Cooling transformer power to control circuit. Heating relay or valve. Cooling relay. Fan relay. Heating ch[...]

  • Page 11

    CT1502, continued SINGLE STAGE HEAT PUMP (WITHOUT AUXILIARY HEAT) SYSTEM I- -1 For CT1503 750-millivolt heating Connect either wire to R terminal and the other wire to W terminal. Firmly tighten screws. Push excess wire back into wall, and plug 0 hole in wall with nonflammable insulation to prevent drafts from affecting thermostat operation. 0 0 / [...]

  • Page 12

    - L MOUNT THE THERMOSTAT or subbase as shown in illustration. Do NOT cycle heating system until Step 7 is completed. 10[...]

  • Page 13

    - SET HEAT ANTICIPATOR LEVER NOTE: Not applicable on CT1503 millivolt model. The thermostat's adjustable heat anticipator 0 must be correctly set to accurately control the on-time length of the system. An incorrect setting can result in room temperature swings or burn out the anticipator and void the thermostat warranty. Make sure you have the[...]

  • Page 14

    On the CT1500. CT1501 or CT1502 thermo- stats, move the heat anticipator indicator to match the number you recorded in Step 4 or found on the primary control as shown above, or as recorded in Step 7 ANTICIPATOR 11,7164 SETTING LEVER INSTALL TIMER F BATTERIES 0 “8 teries in thermostat as shown. Once a year, or when batteries are dead, replace wi[...]

  • Page 15

    SET TIMER Adjust the timer by moving the knob in 0 clockwise direction. Do NOT reverse the knob. When time is correctly set, the Time Indicator Arrow (see illustration) must point to the correct time and the corresponding daytime (lighr) or nighitime (dark) portion of the program dial. 13 69-0273-9[...]

  • Page 16

    I- ATTACH THERMOSTAT COVER 0 “10 Make sure the packing inserts in the thermo- 0 stat base have been removed. as explained in step 3 Place the two tabs on upper edge of cover into mounting slots in thermostat base Swing cover downward until it engages 0 0 catch at bottom of base .. 14[...]

  • Page 17

    CHECK OUT THERMOSTAT OPERATION AND SET TEMPERATURE CONTROL b LEVERS cn il 1 The two levers on top of the thermostat control the low and high temperature for energy savings and comfort control, as shown in illustration. LOW TEMP.lBL"E MARK1 SET LEVER 1 I Do NOT check operation by shorting across terminals of relay or valve coil; this will burn [...]

  • Page 18

    Heating-only System 0 Turn on power to the furnace. 0 Push both temperaturecontrol leverstogetherat least 5" F [3" C] above room temperature. The heat should comeon.Thefan will startwhen the furnace heats up. 0 Move both levers5" F [3" C] below room temper- ature. The heat should shut off. 0 Operate the entire heating system for[...]

  • Page 19

    0 After checkout, reset both temperature levers to desired temperatures. For heating season: [? Move the blue lever to the energy savings temperature you want when you are sleeping or your home is not occupied. 0 Setthered levertothetemperature you want for normal comfort periods. For cooling season: 0 Move the red lever to the energy savings tempe[...]

  • Page 20

    Honeywell Residential and Building Controls Division 740 Ellesmere Road Scarborough, Ontario M1P 2VY Helping You Conlrol Your World Residential and Building Controls Division Honeywell Inc. Honeywell Limited-Honeywell Lunltke 1985 Douglas Drive No. Golden Valley, MN 55422[...]