Homedics BPA-2000-EU manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Homedics BPA-2000-EU, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Homedics BPA-2000-EU one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Homedics BPA-2000-EU. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Homedics BPA-2000-EU should contain:
- informations concerning technical data of Homedics BPA-2000-EU
- name of the manufacturer and a year of construction of the Homedics BPA-2000-EU item
- rules of operation, control and maintenance of the Homedics BPA-2000-EU item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Homedics BPA-2000-EU alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Homedics BPA-2000-EU, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Homedics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Homedics BPA-2000-EU.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Homedics BPA-2000-EU item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Instruction Manual BP A-2000-EU A utoma tic Arm Blood P ressur e Monitor IB-BPA2000-0912-01:Layout 1 09/01/2013 17:50 Page 1[...]

  • Page 2

    2 GB H O M E D I C S B L O O D P R E S S U R E M O N I TO R Before use Before the blood pressur e monitor is taken into use, a number of basic steps should be observed. Please r ead this manual thoroughly befor e the blood pressure monitor is used for the first time and keep the manual f or future use. The blood pressure monit or is intended for ho[...]

  • Page 3

    3 GB Systolic Diastolic arter y p ress r elax v ein blood discharging b lood entering SYS <120 120~129 130~139 140~159 160~179 >180 DIA <80 80~84 85~89 90~99 100~109 >110 Level Blood Pressur e (mmHg) Optimal Normal High-normal Mild Moder ate Severe C AUTI O N Only a physician/GP can tell y ou your normal blood pressure range and the poi[...]

  • Page 4

    4 GB C AUTI O N • This device is intended f or adult use only . • This device is intended for non-invasiv e measuring and monitoring of ar terial blood pressure . It is not intended for use on extremities other than the arm. • Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pr essure. Do not begi[...]

  • Page 5

    5 GB L CD display signal Symbol Description Explanation Systolic blood pressur e High pressure result Diastolic blood pressure Low pressure r esult Pulse Pulse/minute Deflating CUFF is deflating Time (hour:minute) Current time Memory The displayed measur ement values is from the memory. kPa Measurement Unit of the blood pressure mmHg Measurement Un[...]

  • Page 6

    6 GB List M O N I TOR CO M P O N E N T S CUFF AIR HOSE A IR CONNECTOR PL UG L CD DISPLA Y MEM/UP TOUCH KEY ST ART/STOP BUTTON SET/DOWN BUT TON BA T TERY COMP AR TMENT 1. Blood Pressure Monitor 2. Cuff Alternatively an A C adaptor powered mode is available: 100-240V~, 50-60HZ, 400mA ( Y ou can purchase the AC adaptor PP-ADPR2K3K -EU from the HoMedic[...]

  • Page 7

    7 GB S E T T I N G DA T E, T I M E A N D M E A S U R E M E N T U N I T It is impor tant to set the clock before using y our blood pressure monitor , so that a time stamp can be assigned to each recor d that is stored in the memory. (y ear: 2000–2050, time: 24 H) This product uses the Oscillometric Measuring method to detect blood pressure. Befor [...]

  • Page 8

    8 GB Fitting the cuff Correct cu size is critical to accurat e measurement. This monitor comes with a standard size 22-32cm arm cu . A large size cu 32-42cm is available from the HoMedics w ebsite www.homedics.co .uk 1. If the cu is not assembled at rst use, put the end of the cu which is furthest away from the tube thr ough the D[...]

  • Page 9

    9 GB W or th knowing about blood pressure measurement • Blood pressure measuremen ts should be per formed in quiet and comfortable surroundings as measurements can be aected by high or lo w temperatures. The blood pressure should be measured a t normal body temperatures . • Do not move or speak during measurement. Keep your f eet at on th[...]

  • Page 10

    10 GB Recalling records 1 . Please press the “MEM” to show the rec ent record . The number of the recor d, date and time will be shown accordingly . 2 . Press the “MEM” or “SET ” to get the record y ou want. C AUTI O N The most recent r ecord (1) is shown first. Each new measuremen t is assigned to the first (1) record . All other recor[...]

  • Page 11

    11 GB Error search This section includes a list of error messages and frequently asked questions for pr oblems you may encounter with your blood pressure monit or . I f irregularities occur during use, please check the follo wing items. PR OB LE M SYM PTO M CH EC K THI S RE ME DY No power Display is dim or will not light up. Batteries are exhausted[...]

  • Page 12

    12 GB Po wer supply Battery powered mode: 6VDC 4*AA batteries AC adaptor pow ered mode: 100-240V~, 50-60HZ, 400mA ( Y ou can purchase the AC adaptor PP -ADPR2K3K-EU fr om the HoMedics website). Display mode Digital L CD V .A.93*61mm Measurement mode Oscillographic testing mode Measurement range Pressur e: 0~40kpa (0~300mmHg) pulse value: (40~199) t[...]

  • Page 13

    Battery Directive This symbol indicates that batteries must not be disposed of in the domestic wast e as they contain substances which can be damaging to the envir onment and health. Please dispose of batteries in designated collection points. WEEE explanation This marking indicates that this product should not be disposed with other household wast[...]

  • Page 14

    14 GB Guidance and manufacture’ s declaration – electromagnetic emission The BP A-2000-EU is intended for use in the electromagnetic environmen t specified below . The customer of the user of the BP A-2000-EU should assure that it is used in such and en vironment. Emission test Compliance Electromagnetic envir onment – guidance RF emissions C[...]

  • Page 15

    15 GB Guidance and manufacture’ s declaration – electromagnetic immunity The BP A-2000-EU is intended for use in the electromagnetic environmen t specified below . The customer or the user of BP A-2000-EU should assure that it is used in such an en vironment. Immunity test IEC 60601 test level Compliance le vel Electromagnetic environment - gui[...]

  • Page 16

    16 GB T able 3 Guidance and manufacture’ s declaration – electromagnetic immunity – for ME EQUIPMENT and ME SY STEMS that are not LIFE-SUPPORTING Gu i d a n c e a n d m a n u f a ct u r e ’ s d ec l a r a t io n – e l ect r o ma g n et ic i mmu n ity T h e B P A-2 0 0 0 -EU i s in t e n d ed f o r u s e in t h e el ect r o ma g n e t ic e[...]

  • Page 17

    17 GB 16 Recommended separation distances between portable and mobile RF communications equipment and the ELE007839V1 Fitness Equipmen t. The BP A-2000-EU is intended for use in an electromagnetic environmen t in which radiated RF disturbances are controlled . The customer or the user of the BP A-2000-EU can help prevent electromagnetic interferenc[...]

  • Page 18

    0120 IB-B P A-200 0EU- 091 2-0 1 Register your product today a t: http://www.homedicsgr oup.com/r egister HoMedics Group Ltd, HoMedics House Somerhill Business Park, Fiv e Oak Green Road T onbridge, Kent TN11 0GP , UK IB-BPA2000-0912-01:Layout 1 09/01/2013 17:54 Page 244[...]

  • Page 19

    De LED-kaart van de batterij verwijderen | 19 De LED-kaart van de batterij verwijderen GEV AAR: Lees de veiligheidsinstructies die bij de computer werden geleverd alvorens u werkzaamheden binnen de comp uter uitvoert en volg de stappen in "V oordat u begint" op pagina 9. Nadat u werkzaamheden aan de binnenkant van de computer hebt verrich[...]

  • Page 20

    20 | De LED-kaart van de batterij verwijderen 4 Verwijder de schr oef waarmee de LED-k aart aan de onderplaat is bevestigd. 5 T il de LED-kaart omhoog en schuif de ze uit het lipje op de onderplaat. 1 LED-kaart van batterij 2 schroef 1 2[...]