Heat & Glo SL-550TV-D manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heat & Glo SL-550TV-D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heat & Glo SL-550TV-D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heat & Glo SL-550TV-D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heat & Glo SL-550TV-D should contain:
- informations concerning technical data of Heat & Glo SL-550TV-D
- name of the manufacturer and a year of construction of the Heat & Glo SL-550TV-D item
- rules of operation, control and maintenance of the Heat & Glo SL-550TV-D item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heat & Glo SL-550TV-D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heat & Glo SL-550TV-D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heat & Glo service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heat & Glo SL-550TV-D.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heat & Glo SL-550TV-D item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 Models: SL-550TV -D, SL-550TV -IPI-D SL-750TV -D, SL-750TV -IPI-D SL-950TV -D, SL-950TV -IPI-D Owner ’ s Manual Installation and Operation • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to[...]

  • Page 2

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Dealership purchased [...]

  • Page 3

    3 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 - T able of Contents - Section 1: Listing and Code Approvals A. Appliance Certi fi cation ................................... 4 B. Glass Speci fi cations ...................................... 4 C. BTU Speci fi cations ........................................ 4 D. High Al[...]

  • Page 4

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 4 B. Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as de fi ned by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and ce[...]

  • Page 5

    5 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 D. High Altitude Installations U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada. When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input [...]

  • Page 6

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 6 A. Design and Installation Considerations Heat & Glo B-type vent gas appliances are designed to operate with all exhaust gases expelled to the outside of the building, and combustion air pulled from the room. Getting Started 2 When planning an appliance installation, it?[...]

  • Page 7

    7 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward Figure 2.1 B. Negative Pressure Draft is the pressure difference needed to vent fi replaces successfully . Considerations for suc[...]

  • Page 8

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 8 D. Inspect Appliance and Components C. T ools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available. Reciprocating saw Framing material Pliers Hi temp caulking material Hammer Gloves Phillips screwdriver Fr[...]

  • Page 9

    9 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 3 Framing and Clearances NOTE: • Illustrations re fl ect typical installations and are FOR DESIGN PURPOSES ONL Y . • I llustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. Fire Risk Provide adequate clearanc[...]

  • Page 10

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 10 C. Clearances Figure 3.2 Clearances to Combustibles C B D A Fire Risk. • Construct chase to all clearance speci fi cations in manual. • Locate and install appliance to all clearance speci fi cations in manual Fire Risk. Odor Risk. • Install appliance on hard metal o[...]

  • Page 11

    11 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 D. Mantel Projections Figure 3.3 Clearances to Mantels or other Combustibles above Appliance 1/2 INCH (13mm) 12 INCHE S (305mm) TOP FRONT EDGE OF FIREPLACE 12 INCHES (305mm) NON-COMBUSTIBLE MA TERIAL ONL Y[...]

  • Page 12

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 12 A. V ent T ermination Minimum Clearances Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as speci fi ed. • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause fi re. Roo[...]

  • Page 13

    13 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 5 V ent Information and Diagrams Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance. • V ent this appliance directly outside. • Use separate vent system for this ap[...]

  • Page 14

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 14 Fire Risk. Explosion Risk. Insulation and other combustibles must not infringe on clearances. • AL WA YS maintain speci fi ed clearances around venting and fi restop systems. • Install fi restops as speci fi ed. Failure to keep insulation or other material away from[...]

  • Page 15

    15 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 A. Pipe Clearances to Combustibles V ent Clearances and Framing 6 Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as speci fi ed. • Do not pack air space with insulation or other materials. • National building codes recommend using attic shield to ke[...]

  • Page 16

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 16 A. Installing Outside Air Kit Damper Assembly Appliance Preparation 7 CAUTION Sharp Edges • Wear protective gloves and safety glasses dur- ing installation. Asphyxiation Risk. Fire Risk. Do NOT draw outside combustion air from: • W all, fl oor or ceiling cavity . • E[...]

  • Page 17

    17 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 C. Securing and Leveling Appliance The diagram shows how to properly position, level, and secure the appliance (see Figure 7. 3). Nailing tabs are pro- vided to secure the appliance to the framing members. • Place the appliance into position. • Level the appliance from [...]

  • Page 18

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 18 A. Assembly of V ent Sections This B-V ent appliance requires 5-inch (SL-550/750TV -D) or 6-inch (SL-950TV -D) B-vent double-wall pipe. Follow the pipe manufacturer ’ s installation guidelines when installing the unit. This will ensure proper operation and prevent safety [...]

  • Page 19

    19 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 NOTE: Have the gas supply line installed in accordance with local building codes, if any . If not, follow ANSI 223.1. Installation should be done by a quali fi ed installer approved and/or licensed as required by the locality . (In the Commonwealth of Massachusetts install[...]

  • Page 20

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 20 Fire or Explosion Hazard • Gas build-up during line purge may ignite. • Purge should be performed by quali fi ed technician. • Ensure adequate ventilation. • Ensure there are no ignition sources such as sparks or open fl ames. Fire hazard. Explosion Risk. Do NOT c[...]

  • Page 21

    21 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 A. Recommendation for Wire This appliance requires 1 10-120 V AC be wired to the junction box either for use of optional accessories (stand- ing pilot ignition) or for proper operation of the appliance (Intelli fi re ignition). Refer to Figure 10.1 to determine if the appl[...]

  • Page 22

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 22 D. Standing Pilot Ignition System Wiring This s tanding pilot ignition system wiring does not require a 110 VAC supply to operate. Figure 10.3 Standing Pilot Ignition Wiring Diagram Figure 10.2 Intelli fi re Pilot Ignition (IPI) W iring Diagram NOTE: 1 . Ignition module, v[...]

  • Page 23

    23 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 WHT WHT BLK BLK GRN wire inside box Copper ground attached to GRN screw with GRN wire 14/2WG Cover Plate outside firebox Romex Connector F . Wall Switch Installation for Fan (Optional) Figure 10.4 Junction Box Detail Figure 10.5 Fan Control Switch Wiring If the box is being[...]

  • Page 24

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 24 A. Mantel Projections Figure 1 1.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance. Finishing B. Facing Material 11 Figure 1 1.3 Noncombustible Facing [...]

  • Page 25

    25 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 Appliance Setup 12 A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Remove Grate Shipping Support • Remove the log pack and hood, if applicable. • Bend top retaining tab of grate shipping support into vertical position ([...]

  • Page 26

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 26 Log Set Assembly: LOGS-SL550-D G. Positioning the Logs If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions. Carefully remove the logs from the packaging. CAUTION: [...]

  • Page 27

    27 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 LOG #3 (SR V2044-703): Place log #3 on the left two grate bars using the notch on the bottom of log #3. Slide the left edge of log #3 forward until it touches the grate. LOG #4 (SR V2044-701): Place log #4 into the tab on log #1. The bottom notch of log #4 should sit on the[...]

  • Page 28

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 28 LOG #1 (SR V2045-700): Place log #1 on the grate using the notches in the bottom of the log. Slide log #1 up to the front tabs for NG. Slide it back until top of log touches the back of the fi replace for LP . LOG #2 (SR V530-719): Place log #2 on the right two grate bars [...]

  • Page 29

    29 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 LOG #3 (SR V530-718): Place log #3 on the left two grate bars using the notches in the bottom of the log. Position log parallel to log #1 and on the same line as log #2. Left edge of log should rest between grate bar and second tab. LOG #4 (SR V2045-703): Place log #4 on to[...]

  • Page 30

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 30 Figure 12.17 Glass Assembly H. Glass Assembly Removing Glass Assembly Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 12.17). Replacing Glass Assembly Replace the glass door on the appliance. Pull o[...]

  • Page 31

    31 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 A. Before Lighting Appliance Before lighting this appliance determine if it has a Standing Pilot or Intelli fi re ignition system by opening the control access panel to view wiring system and gas valve. If this appliance has a red or black ignitor button (see Figure 10.1) [...]

  • Page 32

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 32 C. Lighting Appliance Intelli fi re Ignition Final Inspection by _____________________________ 1. T urn off all electric power to the appli- ance. 2. This appliance is equipped with an igni- tion device which automatically lights the burner . Do not try to light the burner[...]

  • Page 33

    33 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 1. Turn of f all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not force. 5. Close control access panel. 5. Turn knob[...]

  • Page 34

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 34 D. After Appliance is Lit Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high fo[...]

  • Page 35

    35 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 T roubleshooting 14 Symptom Possible Causes Corrective Actions 1. After repeated triggering of the red or black piezo ignitor button, the spark ignitor will not light the pilot. a. Defective ignitor . Check the spark at the electrode and pilot. If no spark and electrode wir[...]

  • Page 36

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 36 Symptom Possible Cause Corrective Action 3. ...Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the ther- mopile terminals. The millivolt meter should read greater than 125mV . If [...]

  • Page 37

    37 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 B. Intelli fi re Ignition System Symptom Possible Causes Corrective Actions 1. The ignitor/ module makes noise, but no spark. a. Incorrect wir- ing. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are con- nected to correct terminals on module[...]

  • Page 38

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 38 Intelli fi re Ignition System - (continued) Symptom Possible Causes Corrective Actions 3. ...continued d. Damaged pilot assembly or dirty sensor rod. V erify that ceramic insulator around the sensor rod is not cracked, dam- aged, or loose. V erify connection from sensor ro[...]

  • Page 39

    39 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 Maintaining and Servicing Appliance 15 Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance check-up at the beginning of each heating season. Annual inspe[...]

  • Page 40

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 40 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary . 3. V erify no obstructions to air ?[...]

  • Page 41

    41 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 Reference Materials 16 Appliance Dimensions T able A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3 . Figure 16.1 Appliance Dimensions AB CD E F GH I J K L M NO PQR SL[...]

  • Page 42

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 42 B. Service Parts Part number list on following page. 7 Log Set Assembly 14 10 10 12 12 (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 1-06 Ending Manufacturing Date: ______ 1 5 2 4 15 6 13 9 9 SL-550TV -D 1 1 11 8 8[...]

  • Page 43

    43 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 A V AILABLE TO SHIP IN 24 HOURS ITEM COMMON P ARTS SERIAL # P ART NUMBER Burner Ori fi ce NG (#44C) 582-844 Y Burner Ori fi ce LP (#54C) 582-854 Y 1 Mesh Assembly 550-382A Y 2 Burner NG, LP PRE 10-06 POST 10-06 530-206A 530-018 Y Y 3 Glass Door Assembly GLA-550TR Y 4 Log [...]

  • Page 44

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 44 Service Parts Part number list on following page. 10 10 12 12 (NG, LP) Exploded Parts Diagram 9 9 SL-750TV -D 1 1 11 8 8 13 13 7 Log Set Assembly 14 3 5 2 4 16 6 1 15[...]

  • Page 45

    45 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 A V AILABLE TO SHIP IN 24 HOURS ITEM COMMON P ARTS SERIAL # P ART NUMBER Burner Ori fi ce NG (#42C) 582-842 Y Burner Ori fi ce LP (#53C) 582-853 Y 1 Mesh Assembly 530-382A Y 2 Burner NG, LP PRE 10-06 POST 10-06 530-216A 530-019 Y Y 3 Glass Door Assembly GLA-750TR Y 4 Log [...]

  • Page 46

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 46 Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 1-06 Ending Manufacturing Date: ______ SL-950TV -D Part number list on following page. 10 10 12 12 9 9 1 1 11 8 8 13 13 7 Log Set Assembly 14 5 2 4 16 6 1 15 3[...]

  • Page 47

    47 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 A V AILABLE TO SHIP IN 24 HOURS ITEM COMMON P ARTS SERIAL # P ART NUMBER Burner Ori fi ce NG (#42C) 582-836 Y Burner Ori fi ce LP (#53C) 582-851 Y 1 Mesh Assembly 560-382A Y 2 Burner NG, LP PRE 10-06 POST 10-06 534-21 1A 534-017 Y Y 3 Glass Door Assembly GLA-950TR Y 4 Log[...]

  • Page 48

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 48 (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: Ending Manufacturing Date: Service Parts SL-550 / 750 / 950TV -D-IPI Intermittent Pilot Ignition V alve Assembly 2 5 4 1 9 7 8 10 12 6 13 3 11[...]

  • Page 49

    49 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: Ending Manufacturing Date: Service Parts SL-550 / 750 / 950TV -D-IPI A V AILABLE TO SHIP IN 24 HOURS ITEM COMMON P ARTS SERIAL # P ART NUMBER 1 Jumper Wires 2012-206 Y 2 Thermostat Wire Assembly 2045-024 Y 3 Burn[...]

  • Page 50

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 50 Service Parts (NG, LP) Exploded Parts Diagram SL-550 / 750 / 950TV -D Standing Pilot Ignition V alve Assembly 1 2 4 5 6 3 8 7 Beginning Manufacturing Date: Ending Manufacturing Date: 9[...]

  • Page 51

    51 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 Service Parts (NG, LP) Exploded Parts Diagram SL-550 / 750 / 950TV -D A V AILABLE TO SHIP IN 24 HOURS ITEM COMMON P ARTS SERIAL # P ART NUMBER 1 Piezo Ignitor 291-513 Y 2 Burner Neck Gasket 2045-407 3 Thermostat Wire Assembly 2045-024 Y 4 Pilot Assembly NG PRE 10-06 POST 10[...]

  • Page 52

    Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 52 C. Limited Lifetime W arranty © 2005 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY HEA T & GLO GAS APPLIANCE PRODUCTS 060-981D 3/05 BASIC ONE-YEAR W ARRANTY . HEA T & GLO, a brand of HEAR TH & HOME TECHNOLOGIES INC., located at 20802 Kensingto[...]

  • Page 53

    53 Heat & Glo • SL-550 / 750 / 950TV -D • 2053-985 Rev . H • 9/06 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com - NOTES - ________________________________________________________________________________ _____________________________________________________[...]