Heat & Glo 8000TR-OAK manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heat & Glo 8000TR-OAK, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heat & Glo 8000TR-OAK one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heat & Glo 8000TR-OAK. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heat & Glo 8000TR-OAK should contain:
- informations concerning technical data of Heat & Glo 8000TR-OAK
- name of the manufacturer and a year of construction of the Heat & Glo 8000TR-OAK item
- rules of operation, control and maintenance of the Heat & Glo 8000TR-OAK item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heat & Glo 8000TR-OAK alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heat & Glo 8000TR-OAK, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heat & Glo service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heat & Glo 8000TR-OAK.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heat & Glo 8000TR-OAK item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 1 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in[...]

  • Page 2

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership p[...]

  • Page 3

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indic[...]

  • Page 4

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 4  = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 52 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 14 Appliance Setup A. Remove Fixed G[...]

  • Page 5

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 5 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an auth[...]

  • Page 6

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 6 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic[...]

  • Page 7

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC). The t[...]

  • Page 8

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by t[...]

  • Page 9

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECOR[...]

  • Page 10

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage th[...]

  • Page 11

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . 1. Turn off all electric power to the appliance.[...]

  • Page 12

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 12 J. Lighting Instructions (Standing Pilot) 1. Turn of f all electric power to the appliance if ser- vice is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to[...]

  • Page 13

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 13 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.H. • Clean fi xed glass assembly .[...]

  • Page 14

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming[...]

  • Page 15

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 15 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clear[...]

  • Page 16

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 16 (Either cobrahead or SIT) PRODUCT SPECIFIC Figure 3.1 IPI Pilot Flame Patterns Figure 3.2 Standing Pilot Flame Patterns[...]

  • Page 17

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 17 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System [...]

  • Page 18

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 18 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is[...]

  • Page 19

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 19 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around ai[...]

  • Page 20

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 20 C B D A B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops a[...]

  • Page 21

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 21 1 in. MIN. 3 ft. MAX. TOP VIEW 3-1/2 in. MIN. 3 5 6 7 8 9 10 2 3 4 5 12 11 10 9 8 7 6 TOP O F H OOD 4 12 13 11 32 CE IL ING 1 2 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi[...]

  • Page 22

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 22 Figure 6.3 Leveled T ermination Caps A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* O[...]

  • Page 23

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 23 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches...............[...]

  • Page 24

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 24 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems. Refer to Section 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe i[...]

  • Page 25

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 25 H 1 V 1 Figure 7.3 Figure 7.4 One Elbow T wo Elbows Note: For corner installations: A 6 in. (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow , to allow the vent pipe to clear the top standoffs. INST ALLED H[...]

  • Page 26

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 26 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 3 ft 914 mm 1-1/2 ft. 457 mm 6-1/2 ft. 2 m 2 ft. 607 mm 9-1/2 ft. 2.9 m 1 ft. 305 [...]

  • Page 27

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 27 T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/termination of f the top of the appliance, the fl ue restrictor should be used. V 1 V 1 = 50 ft. Max. (15.2 m) V 1 = 3 ft. Min. (914 mm) Installing Flue Restri[...]

  • Page 28

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 28 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum One Elbow 3 ft 914 mm * * * 2 ft 607 mm 10 ft 3.1 m * * * 4 ft 1.2 m 20 ft 6.1 m * * * V 1 + V 2 + H 1 = 50 ft (15.2 m) Maximum *No speci fi c restrictions on this value EXCEPT V 1 + V 2 + H 1 cannot exceed 50 ft [...]

  • Page 29

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 29 Rear V ent - Horizontal T ermination Figure 7.13 Figure 7.14 No Elbow One 45º Elbow H 1 = 1-1/2 ft. (457 mm) Maximum H 1 = 9 in. (229 mm) Maximum H 1 H 1 This model is tested and approved to use 45º elbows in corner installations. However , 90º elbo[...]

  • Page 30

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 30 Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.15 Figure 7.16 Three Elbows H 1 H 2 V 1 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 2 ft 610 mm T wo 90º Elbows back to back 3-1/2 ft 1.0 [...]

  • Page 31

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 31 INST ALL ED HORIZONT ALL Y H 1 H 2 V 2 Rear V ent - V ertical T ermination One Elbow Figure 7.17 T wo Elbows Figure 7.18 V 1 Minimum H 1 Maximum 6 in 152 mm 2 ft 607 mm 1-1/2 ft 457 mm 4 ft 1.2 m 2-1/2 ft 762 mm 6 ft 1.8 m 3-1/2 ft 1.0 m 8 ft 2.4 m V 1[...]

  • Page 32

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 32 Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.19 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 2 ft 610 mm 1 ft 305 mm 3-1/2 ft 1.0 m 5 1/2 ft 1.7 m 4 ft 1.4 m 1-1/2 ft 457 mm 4 ft 1.4 m 8 ft 2.4 m 8 ft 2.4 m 3-1/2 ft 1.0 m 8 [...]

  • Page 33

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 33 8 8 V ent Clearances and F raming A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Aro[...]

  • Page 34

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 34 Figure 8.6 W all Penetration B. W all Penetration Framing Figure 8.5 Horizontal V enting Clearances to Combustible Materials 3 IN. TOP CLEARANCE HEA T SHIELD HEA T SHIELD WA LL WA LL SHIELD FIRESTOP 1 IN. CLEARANCE BOTTOM SIDES Note: Heat shields MUST [...]

  • Page 35

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 35 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.7). • Frame the area[...]

  • Page 36

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 36 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an a[...]

  • Page 37

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 37 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. A. T op V e[...]

  • Page 38

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 38 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. Figure 9.6 Fold the tabs toward the center of the seal cap (90º) and remove the insulation gasket. Figure 9.7 Cut the metal retaining band an[...]

  • Page 39

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 39 C. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- [...]

  • Page 40

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 40 PILOT PLA TE Figure 9.14 Note: E n s u r e p i l o t p l a t e i s i n p l a c e . T h i s w i l l e n s u r e p i l o t stabilit y ( see Figure 9. 1 4) E. Checking Pilot Plate Figure 9.13 Re-install grate in unit RE-INSTALL INTO THE UNIT D. Completing[...]

  • Page 41

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 41 1 0 10 Installing V ent Pipe A. Assemble V ent Sections Attach V ent to the Firebox Assembly Note: The end of t he pipe secti ons with the lanc ed tabs wi ll face toward the applianc e. Attach the fi rst pipe section to the starting collar: • Lanced[...]

  • Page 42

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 42 B. Assemble Slip Sections • Slide the inner fl ue of the slip section into the inner fl ue of the pipe section and the outer fl ue of the slip section over the outer fl ue of the pipe section. See Figure 10.6. • Slide together to the desired le[...]

  • Page 43

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 43 D. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully to separate the pieces of pipe. Figure 10.1 1 Align and Disassemble V ent Sections F[...]

  • Page 44

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 44 E. Install Metal Roof Flashing Note : Skip this section if using the RF4-8. • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe se[...]

  • Page 45

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 45 G. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 10.G. and 10.H.) Pipe must be supported within 12 inches of the roofline using plumbers strapping or an SLP-FS when using the RF4-8 Flashing. Refer to Sec[...]

  • Page 46

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 46 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.23 Figure 10.23 TERMINA TION CAP H. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing t[...]

  • Page 47

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 47 Figure 10.25 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WA LL (SEE CHART BELOW)[...]

  • Page 48

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 48 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum app[...]

  • Page 49

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 49 Figure 12.1 Ignitor Button C. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 1 10 V AC supply to operate. See Figure 12.3. • A 1 10 V AC junction box MUST be installed for use with a fan or remo[...]

  • Page 50

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 50 ON OFF ON/OFF SWITCH REMOTE SWITCH PIGTAIL OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE STANDING PILOT WHT RED VALVE E. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors[...]

  • Page 51

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 51 G. W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from t[...]

  • Page 52

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 52 1 in. MIN. 3 ft. MAX. TOP VIEW 3-1/2 in. MIN. A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materi-[...]

  • Page 53

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 53 A. Remove Fixed Glass Assembly See Section 14.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or under[...]

  • Page 54

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 54 G. Install the Log Assembly If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions. CAUTION: Carefully remove the logs from the packaging. Logs [...]

  • Page 55

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 55 STEP 5: (SR V2057-723): Mate the top of log 4 with the right metal tab on log 3. The bottom of log 4 should touch the inside face of the right grate tine. 2 3 1 2 3 1 5 4 2 3 5 6 STEP 7: (SR V2057-725): Place log 6 on log 2 as shown. The left end of lo[...]

  • Page 56

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 56 L. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Fig[...]

  • Page 57

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 57 A. Standing Pilot Ignition System 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali[...]

  • Page 58

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 58 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) C. V alve. T urn the valve knob to the ON position. Place the ON/ OFF switch in the ON position. T ake a reading with a millivolt meter at the thermopile terminals. Th[...]

  • Page 59

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 59 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. A. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are conn[...]

  • Page 60

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 60 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi ca[...]

  • Page 61

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 61 1 6 16 R eference Mater ials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions D S P M L N F J K Ø E C B A H G [...]

  • Page 62

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 62 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) [...]

  • Page 63

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 63 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield [...]

  • Page 64

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 64 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in. (349 mm) 5 in. (127 mm) 13-3/4 in. ([...]

  • Page 65

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 65 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV VerticalTermination Cap 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 m[...]

  • Page 66

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 66 C. Service Parts Part number list on following page. Service Parts Diagram 8000TR-OAK, 8000TR-OAK-IPI Beginning Manufacturing Date: Feb. 2006 Ending Manufacturing Date: ______ 8 9 10 11 12 13 7 Log Set Assembly 6 3 5 1 4 2[...]

  • Page 67

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 67 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM D[...]

  • Page 68

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 68 Intermittent Pilot Ignition V alve Assembly Service Parts V alve Assembly Diagram/ Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All [...]

  • Page 69

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 69 Standing Pilot Ignition V alve Assembly Service Parts V alve Assembly Diagram/ Parts List 8000TR-OAK Beginning Manufacturing Date: Feb. 2005 Ending Manufacturing Date:______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replaceme[...]

  • Page 70

    Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev . P • 1 1/08 70 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215th St, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat [...]