Harman Stove Company P43 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Harman Stove Company P43, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Harman Stove Company P43 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Harman Stove Company P43. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Harman Stove Company P43 should contain:
- informations concerning technical data of Harman Stove Company P43
- name of the manufacturer and a year of construction of the Harman Stove Company P43 item
- rules of operation, control and maintenance of the Harman Stove Company P43 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Harman Stove Company P43 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Harman Stove Company P43, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Harman Stove Company service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Harman Stove Company P43.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Harman Stove Company P43 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    R1 P43 Pellet Stove Owners Manual SA VE THESE INSTRUCTIONS. Installation & Operating Manual R1 “Ce manuel est disponible en Français sur demande” SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INST ALL AND USE YOUR NEW ROOM HEA TER. F AILURE TO FOLLOW INSTRUCTIONS MA Y RESUL T IN PROPERTY DAMAGE, BODIL Y INJUR Y , OR EVEN DEA TH. [...]

  • Page 2

    2 P43 Pellet Stove Harman PP38+/P43 Pellet Stove Label measures: 4-3/8" high X 9-3/4"wide MINIMUM CLEARANCES TO COMBUSTIBLES: SIDEWALL T O STOVE 16" 10" BACKWALL T O STOVE 2" 2" CEILING TO ST OVE TOP 18" 18" STOVE CORNER T O DIAGONAL W ALL 9" 9" PREVENT HOUSE FIRES, OPERA TE WITH VIEWING & ASH D[...]

  • Page 3

    3 P43 Pellet Stove Safety Information 4 Installation 5 V enting 7 ESP Control 14 Automatic Operation 15 Manual Operation 18 Low Draft V oltage Adjustment 20 Room Sensor 21 Maintenance 22 T rouble Shooting 26 Feeder Parts 27 Specications    28 Options 29 Wiring Diagram 30 Parts List 31 W arranty 32 Ple ase read thi s entir e manual be[...]

  • Page 4

    4 P43 Pellet Stove DO NOT INST ALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT . DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SER VING ANOTHER APPLIANCE. MOBILE HOME INST ALLA TION SHOULD BE DONE IN ACCORDANCE WITH THE MANUF ACTURED HOME AND SAFETY ST ANDARD (HUD), CFR 3280, P ART 24. CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME F[...]

  • Page 5

    5 P43 Pellet Stove Assembly and Installation Unpacking The P43 is bolted (1/4 x 1" hex head bolts) to the skid to prevent movement during shipping. T o free the stove from the skid you must remove the hold-down bolts in the rear of the pedestal base. Removing rear cover panels The rear cover panels are secured to the stove with three bolts eac[...]

  • Page 6

    6 P43 Pellet Stove Installing Place the stove on a noncombustible oor protector that extends a minimum of 6 inches to the front, (mea- sured from the glass) 6 inches to the sides and 1 inch to the rear of the hopper . In some places, it is required that oor protection be installed under any horizon[...]

  • Page 7

    7 P43 Pellet Stove V enting Requirements for T erminating the V enting W ARNING: V enting terminals must not be recessed into a wall or siding. NOTE: Only approved pellet vent pipe, wall pass- throughs, and re stops should be used when venting through combustible materials. NOTE: Always take into consideration the ef f[...]

  • Page 8

    8 P43 Pellet Stove V enting A co mb us ti on b lo we r is us ed t o ext ra ct t he combustion gases from the rebox. This causes a negative pressure in the rebox and a positive pres - sure in the venting system as shown in Fig. 7. The longer the vent pipe and more elbows used in the system, th[...]

  • Page 9

    9 P43 Pellet Stove Outside air ex pipe goes here. Inlet Cover part# 1-10-08542 Flex pipe part# 1-00-08543 (25') Outside Air Here a refourbenetsof outside air: 1. Having air introduced from outside the living area boosts thermal efciency . Because the make up air is not being drawn in through leaky windows[...]

  • Page 10

    10 P43 Pellet Stove #2 Preferred method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to ve feet high and at lea st thre e i nch es fro m a co mbu sti ble w all . Thi s vertical sec[...]

  • Page 11

    1 1 P43 Pellet Stove #4 Installing into an existing chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable* you may want to install a liner as in method #7. In some places in the US and Canada it is required that the vent [...]

  • Page 12

    12 P43 Pellet Stove #6 Installing into an existing replace chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. In some places in the US and Canada it is re- quired that the vent pipe extend all the way to the top of the chimney . The pipe or liner inside th[...]

  • Page 13

    13 P43 Pellet Stove #8 Installing through the ceiling Through the ceiling vent, follow PLvent manufacturers recommendations when using wall and ceiling pass through. Note: Do not place joints within wall pass-throughs. Fig. 14 PL vent manufacturer's firestop spacer and support (See Page 6 for corner installation clearances) Minimum flue vent c[...]

  • Page 14

    14 P43 Pellet Stove P43 AUTOMA TIC IGNITION ESP CONTROL Feed adjuster Sets the maximum feed rate T est Runs all motors at full speed for one minut e to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remin d you that you are still in "T est Mode". Igniter[...]

  • Page 15

    15 P43 Pellet Stove P43 AUTOMA TIC IGNITION/OPERA TION Room T emperature Mode: This setting, see above, will produce a room temperature of 70 degrees with the distribution blower at medium speed. The P43 is a fully automatic stove that features two op era ting mod es ; Stov e T em pera ture Mod e and Roo m T emperature Mode . In Stove T emperature [...]

  • Page 16

    16 P43 Pellet Stove Stove T emperature Mode In the Stove T emperature Mode and with the igniter toggle switch in the Auto position, the stove will light automa tically and can be adjusted to the desire d setting using the same temperature control dial as is used in the Room T emperature Mode. The heat output and fuel consumption will remain constan[...]

  • Page 17

    17 P43 Pellet Stove Igniter Switch to"AUTO"(up position) Make sure the unit is plugged into a 120 V AC, 60 HZ electrical source. The power light should be the only light lit. 1. T urn Mode Selector to "OFF". 2. Fill hopper with pellets. 1 3. Clean burn pot with scraper , if necessary . 5 4. If starting after an empty hopper , tu[...]

  • Page 18

    18 P43 Pellet Stove The P43 Pellet Stove is capable of manual operation. This also allows the operator to manually control operation during an emergency (i.e. igniter failure, when using a 502H battery backup, as opposed to the 512H, or when using certain generators.) The unit can be switched between "AUTO" and "MANUAL" at any t[...]

  • Page 19

    19 P43 Pellet Stove P43 MANUAL ST ART UP Igniter Switch to"MANUAL" (down position) Make sure the unit is plugged into a 120 V AC, 60 HZ electrical source. The power light should be the only light lit. 1. T urn FEED ADJUSTER to desired feed rate . No. 4 is good for most pellets. 4 2. T urn the MODE SELECTOR to “OFF” and then to the des[...]

  • Page 20

    20 P43 Pellet Stove These units are pre-tested at the factory with exactly 120 V olts A.C., 60 Hz. They are checked and adjusted for rebox tightness, gasket leakage, motor operation and igniter operation. The P43 is then factory set at a mid -poi nt adju stme nt and in most case s will not need any adj ustm ent s. NOTE : The[...]

  • Page 21

    21 P43 Pellet Stove The room sensor is a small temperature sensor on the end of a 60" wire. This sensor is installed much like a standard wall thermostat. Because it is so small, it can be hidden along the trim of a door- way or even up the leg of a coffee table. There is a remote room sensor port on the rear of the unit for easy external conn[...]

  • Page 22

    22 P43 Pellet Stove Removing Ashes: When approximately 1 ton of pellets has been burned, it will be necessary to empty the ash pan. Ash es sh oul d be pla ced in a meta l cont ain er with a tight tting lid. The closed container of ashes should be placed on a noncombustible oor or on the ground, well away from all com - bustible materials, pen[...]

  • Page 23

    23 P43 Pellet Stove Exposed blower wheel and ue opening, NOTE: ESP probe is visible. Blower cover removed. ESP probe 8. Clean the combustion blower wheel with a brush and a vacuum cleaner . Note: Do not use a household vacuum to clean the stove. W e recommend that you usea shopvacuumthat isequipped witha nedust?[...]

  • Page 24

    24 P43 Pellet Stove Burn Pot Cleaning and Maintenance 1. Scrape the top holed surface and sides of the burn pot. (Fig 33) It is not neces sary to comple tely remove all material from the burn pot. The excess will be pushed out during the next use. 2. Loosen the (2) wing thumb screws on the lower front angle of the burn pot. (Fig. 34) 3. Li ft of f [...]

  • Page 25

    25 P43 Pellet Stove P43 Maintenance - Cleaning the Feeder Body Pellet nes will accumulate in the feeder body over a period of time; therefore, a yearly inspection and cleaning of this area must be performed. T ocleanoutnes: 1. Remove the rear cover panels. 2. Remove wing nut and feeder cover on the side of [...]

  • Page 26

    26 P43 Pellet Stove FEEDER DOES NOT FEED 1. No pellets in hopper . 2. Firebox draft may be too low for low draft pressure switch in feeder circuit to operate. Check for closed doors , loose or missing gasket on doors or hopper lid, or a faulty pressure switch. 3. Fe ed mot or wil l not ru n unt il th e ESP co ntr ol se nses 165 deg. F . Maybe you d[...]

  • Page 27

    27 P43 Pellet Stove P43 Feeder[...]

  • Page 28

    28 P43 Pellet Stove Weight 212 lbs. Blower 135 cfm Feed Rate approximate .75lb. to 5.5 lbs per hr Hopper Capacity 50 lbs Fuel Wood Pellets Flue Size 3 inch Outside Air Size 2 3/8" I.D. inch Fuse Rating 6 amp P43 Specications 12.375" 5.25" 32" 9" 22" 28.5"[...]

  • Page 29

    29 P43 Pellet Stove OPTIONS Side Heat Shields Side heat shields are available to reduce the clearance to combustible materials. Part #1-00-00000 Hopper Extension The hoppe r ext ensi on allows you to put more pellet fuel in the hopper and extends burn time on one load of pellets. The hopper extension adds 60 pounds to the existing 60 pound hopper c[...]

  • Page 30

    30 P43 Pellet Stove P43 Wiring Diagram[...]

  • Page 31

    31 P43 Pellet Stove Description Part Number Hopper Gasket(5 ft.) 0-88-00248 Ash Pan Assembly 1-10-7738108 Burn Pot Weldment 1-10-00675 Right Rear Shield 2-00-773828-1P Left Rear Shield 2-00-773828-2P Arrow Scraper 2-00-773850 Flame Guide 3-00-03000 Wiring Harness Assembly 3-20-08727 Thermister Probe 3-20-00844(red wire) Room Sensor 3-20-00906 Circu[...]

  • Page 32

    HARMAN GOLD W ARRANTY 6 YEAR TRANSFERABLE LIMITED W ARRANTY (Residential) 1 YEAR LIMITED W ARRANTY (Commercial) Harman warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service, for [...]