Greenheck Fan SP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Greenheck Fan SP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Greenheck Fan SP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Greenheck Fan SP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Greenheck Fan SP should contain:
- informations concerning technical data of Greenheck Fan SP
- name of the manufacturer and a year of construction of the Greenheck Fan SP item
- rules of operation, control and maintenance of the Greenheck Fan SP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Greenheck Fan SP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Greenheck Fan SP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Greenheck Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Greenheck Fan SP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Greenheck Fan SP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Centrifugal Ceiling and Cabinet Exhaust Fans Models SP and CSP November 2006 Making a Sound Difference with Silent Solutions[...]

  • Page 2

    2 Greenheck Fan Corporation certifies that the SP models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Models SP and CSP are listed electric fans (U[...]

  • Page 3

    3 Light Options: L - Fan/Light (Incandescent) Combination FL - Fan/Light (Fluorescent) Combination SP - A 50 FL Nominal cfm at 0.10 inches static pressure Level of Construction: A - Premium unit; lowest sound, insulated housing B - Deluxe unit; low sound, low profile C - Standard unit; lowest profile, inexpensive Model: SP - Silent Partner CSP - Ca[...]

  • Page 4

    4 PREMIUM CEILING FAN A SP Spring Loaded Aluminum Backdraft Damper - Eliminates rattling or unwanted backdrafts. Outlet - Both square and round outlets are field rotatable from horizontal to vertical discharge. Power Assembly - Removes quickly for maintenance or conversion from horizontal to vertical discharge. External Electrical Access - Eliminat[...]

  • Page 5

    5 PREMIUM CEILING FAN A SP The frosted lens option is a traditional design which lets approximately 80% of light through the lens. The lens may be easily removed to replace light bulbs. The prismatic lens design provides approximately 25% more light than a traditional frosted lens. The lens may be easily removed to replace light bulbs. (Patent Pend[...]

  • Page 6

    6 DELUXE CEILING FAN B SP Aluminum Backdraft Damper - Prevents unwanted backdrafts. Round Standard Outlet (4 or 6 in.) - Versatile for quick, easy connections. Power Assembly - Removes quickly for maintenance. Electrical Access (vertical) - Eliminates drilling holes. Disconnect - Servicing is quick and safe. Electrical Junction Box - Large for easy[...]

  • Page 7

    7 DELUXE CEILING FAN B SP National Fire Protection Association (NFPA) Standard 90A requires openings in fire rated ceiling/floor assemblies be protected by appropriately rated ceiling radiation dampers. As a result, many local codes require fans installed in fire rated ceilings must also be protected by dampers which are insulated against both heat[...]

  • Page 8

    8 STANDARD CEILING FAN C SP Plastic Backdraft Damper - Prevents unwanted backdrafts. Round Outlet - 3 inch diameter allows quick easy connections. Power Assembly - Removes quickly for maintenance. Disconnect - Servicing is quick and safe. Polymeric Grille - Quickly snaps into place. Mounting Brackets - Adjustable for several installation types. Hou[...]

  • Page 9

    9 ® Things to know, when sound is critical Things to know, when sound is critical Sound Data The sound data shown in this catalog has been presented to aid the system designer in selecting a fan which will meet the desired sound criteria. Sone levels have been included on the performance pages to provide a means of quickly evaluating the relative [...]

  • Page 10

    10 PREMIUM INLINE FAN A CSP The CSP-A is a Premium Inline Fan. It outperforms the competition and is preferred by specifying engineers. Profile as low as 10 1 / 2 inches. Sound levels as low as 0.8 sones. Air volume as high as 3,778 cfm. UL/cUL Listed. • • • • Spring Loaded Aluminum Backdraft Damper - Eliminates rattling or unwanted backdra[...]

  • Page 11

    11 DELUXE INLINE FAN B CSP The CSP-B is a compact Deluxe Inline Fan. It is designed to fit in small remote quarters. Profiles as low as 6 15 / 16 inches. Sound levels as low as 2.0 sones. Air volume as high as 186 cfm. UL/cUL Listed. • • • • Aluminum Backdraft Damper - Prevents unwanted backdrafts. Round Standard Outlet (4 or 6 in.) - Versa[...]

  • Page 12

    12 EXTERNAL JUMPER LOAD LOAD 115 VOL T AC 60 CYCLE (NEUTRAL) (HOT) BLACK BLUE (500 Watt Max) LIGHT (7.5 Amps Max) FAN MOTOR RED WHITE FULL VOL T AGE 120 VAC N H BLACK SPEED CONTROL WHITE VARIABLE VOL T AGE FAN AUX DEVICE SWITCHED FULL VOL T AGE Dotted line indicates for use with 10W switch only . RED Model 5WSSC - For use w/ shaded pole and PSC mot[...]

  • Page 13

    H 1 BLK SWITCH BOX SWITCH 115 V MOTOR 277 V SUPPL Y 277V TO 115V TRANS. 750 VA H 2 H 3 RED X 1 X 2 RED BLK BLK Grille Motion Detectors are available on models up through size SP-A390 and SP-B200. • Rated for 115v • UL Listed Model MDW For use on fan or lights. Available shipped loose. • Rated for 115v • UL Listed • Requires 2x4 handy box [...]

  • Page 14

    14 E B C A D D A G C B E F B E C A D E B C A Model WL Wall Louvered Discharge • Anodized aluminum grille • Built in damper • Not recommended for exterior applications exposed to severe weather conditions. An external wall louver is recommended for such applications. Model WC (Round Connection) Hooded Wall Cap • Aluminum construction - alumi[...]

  • Page 15

    15 Model RCC-7 Curb Cap • Weathertight aluminum construction • Integral birdscreen • Built in curb cap • Requires roof curb Model RJ Pitched Roof Cap • Steel construction with black enamel finish • Integral flashing flange • Built in birdscreen and damper Model A B C D E Throat RJ-4 C50, B50-B80 11 9 1 / 4 8 1 / 4 5 5 / 16 4 1 / 2 4 i[...]

  • Page 16

    PREMIUM CEILING FAN A SP Dimensional Data Performance Data Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness[...]

  • Page 17

    DELUXE CEILING FAN B SP STANDARD CEILING FAN C SP 17 HVI CFM / Static Pressure in inches of WG Model RPM AMPS Watts Sones 0.000 0.100 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM 67 53 51 40 29 SP-B50 625 0.50 38 1.4 Sones 1.7 1.9 1.9 2.6 3.5 CFM 77 70 68 57 49 39 SP-B70 675 0.53 45 1.4 Sones 1.7 1.9 1.9 2.4 3.1 3.6 CFM 87 80 78 68 61 54 44 30 SP-[...]

  • Page 18

    18 PREMIUM INLINE FAN A CSP Dimensional Data Performance Data Performance certified is for Model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fa[...]

  • Page 19

    19 DELUXE INLINE FAN B CSP Performance certified is for Model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) from the te[...]

  • Page 20

    Greenheck Fan Corporation warrants its SP/CSP products to be free of any defect in material or workmanship for a period of three (3) years from the date of purchase. In the event of such a defect during the warranty period, Greenheck Fan Corporation agrees, at its option, to either repair or replace the defective product free of charge. This warran[...]