Greenheck Fan 474051 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Greenheck Fan 474051, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Greenheck Fan 474051 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Greenheck Fan 474051. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Greenheck Fan 474051 should contain:
- informations concerning technical data of Greenheck Fan 474051
- name of the manufacturer and a year of construction of the Greenheck Fan 474051 item
- rules of operation, control and maintenance of the Greenheck Fan 474051 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Greenheck Fan 474051 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Greenheck Fan 474051, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Greenheck Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Greenheck Fan 474051.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Greenheck Fan 474051 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Fiberglass Centrifugal Fan Installation, Operation and Maintenance Manual Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Pr otect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury [...]

  • Page 2

    2 Model BCSW-FRP Fans are pr otected against damage during shipment. If the unit cannot be installed and operated immediately , precautions need to be taken to pr event deterioration of the unit during storage. The user assumes responsibility of the fan and accessories while in storage. The manufacturer will not be r esponsible for damage during st[...]

  • Page 3

    3 Model BCSW-FRP CAUTION When installing a fan, ensure the pr oper protective devices are used to pr otect personnel from moving parts and other hazards. A complete line of protective accessories ar e available from Greenheck including belt guar ds, shaft guards, and electrical disconnects. Electrical Disconnects All fan motors should have disconne[...]

  • Page 4

    4 Model BCSW-FRP Ducted Outlet Installations Discharge Duct Turns - Duct turns located near the fan discharge should always be in the direction of the fan rotation. Fan performance is reduced when duct turns are made immediately off the fan discharge. T o achieve cataloged fan performance there should be at least three equivalent duct diameters of [...]

  • Page 5

    5 Model BCSW-FRP Bases (Foundation and Isolation) In order to assur e continued alignment, a high strength, non-shrink epoxy gr out is recommended to provide the desir ed mechanical properties for support of the fan. This type of support ensures the appropriate transmission of static and dynamic loads to the equipment foundation. T o eliminate vibr[...]

  • Page 6

    6 Model BCSW-FRP Radial Gap, Overlap and Wheel Alignment Efficient fan performance can be maintained by having the correct radial gap, overlap and wheel alignment. These items should be checked after the fan has been in operation for 24 hours and before start-up after the unit has been serviced. Radial Gap is adjusted by loosening the housing bolts[...]

  • Page 7

    7 Model BCSW-FRP Flexible Couplings (Arr . 8 Only) Check for misalignment between the coupling halves. Parallel and angular misalignment and separation gap are illustrated below . Refer to coupling manufacturer’ s installation instructions for allowable misalignment and separation gap tolerances. When correcting for misalignment using shims, the [...]

  • Page 8

    8 Model BCSW-FRP Vibration Excessive vibration is the most frequent pr oblem experienced during initial start-up. Left unchecked, excessive vibration can cause a multitude of problems, including structural and/or component failure. Many of these conditions can be discovered by car eful observation. Refer to the troubleshooting section of this manua[...]

  • Page 9

    9 Model BCSW-FRP Routine Maintenance Once the unit has been put into operation, a routine maintenance schedule should be set up to accomplish the following: 1. Lubrication of bearings and motor (see below). 2. Wheel, housing, bolts and set screws on the entire fan should be checked for tightness. 3. Any dirt accumulation on the wheel or in the hous[...]

  • Page 10

    10 Model BCSW-FRP Parts List Housing Wheel Gasket Backplate Shaft Guard Shaft Seal Shaft Belt Guard Belt Guard Cover Belt Motor Pulley Shaft Pulley Adjustable Motor Slide Base Bearings Inlet Cone Outlet Flange Base/Housing Foot Angle (4) Access Door with Gasket V-Belt Drives V -belt drives must be checked on a regular basis for wear , tension, alig[...]

  • Page 11

    11 Model BCSW-FRP Problem Cause Corrective Action Excessive Noise Wheel rubbing (inlet) Adjust wheel. Tighten wheel hub or bearing collars on shaft. V -belt drive Tighten Sheaves on motor/fan shaft. Adjust belt tension. Align sheaves properly (see V -Belt Drives section). Replace worn belts or sheaves. Bearings Replace defective bearing(s). Lubrica[...]

  • Page 12

    12 474051 • BCSW-FRP , Rev . 1, November 2010 Copyright 2010 © Greenheck Fan Corporation ® Phone:(715)359-6171•Fax:(715)355-2399•E-mail:gfcinfo@greenheck.com• W ebsite: www .greenheck.com AMCA Publication 410-96, Safety Practices for Users and Installers of Industrial and Commercial Fans, pr ovides additio[...]