Graco 312964C manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 312964C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 312964C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 312964C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 312964C should contain:
- informations concerning technical data of Graco 312964C
- name of the manufacturer and a year of construction of the Graco 312964C item
- rules of operation, control and maintenance of the Graco 312964C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 312964C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 312964C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 312964C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 312964C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    The Matr ix Tank Lev el Monitor co ntains an R F device w ith the fo llowing appro vals: FCC ID: TFB-FREEST AR IC: 5969A-FREEST AR Industry Canada Statement The term “IC” before t he certification/reg istra- tion number only signifies tha t the Industr y Canada technical specifications were met. ✓ N14939 - FREESTAR ZFMSM-101 -1 (CEL) / FS24-1[...]

  • Page 2

    Warnings 2 312964C Wa r n i n g s The f ollowing warnings are f or the setup , use, groundin g, maintenance, and repair of this equ ipment. The exclama- tion point symbol alerts you to a gener al warning and the hazard symbol ref ers to procedure -specific risk. Refer bac k to these wa r nings. Additional, pr oduct- specific warnings ma y be found [...]

  • Page 3

    Set Up 312964C 3 Set Up Dips witch Settings The TLM has two , 4 - position dips witches labeled S1 and S2. TLM dips witches must be set to match those of the transceiver the TLM will be communicating with. The f actor y default setting for all TL M’ s is (‘1’ ‘1’). The first ‘1’ refers to the Network ID and the sec ond ‘1’ refers [...]

  • Page 4

    Set Up 4 312964C 7. Install tw o, 9-v olt alkaline batteries (1). Be sure that the batter ies fully engage the mounting clips by pushing on the botto m of each battery with your thumb . 8. Replace insulating f oam (4). 9. Replace co ver (7) and secure it with the f our screws (3). It will take about 30 seconds f or the monitor to dis- play inf or m[...]

  • Page 5

    Set Up 312964C 5 Dipswitc h Setting for Netw ork ID and T ransceiver ID See F IG . 3 f or dips witch setting configur ations. b The batteries must be di sconnected and remov ed before changi ng dips witch settings or the TLM will not be able to communic ate with the PC software. F IG . 3 1 - def ault S2 Transceiver ID 12 3 4 S2 on 2 12 3 4 S2 on 3 [...]

  • Page 6

    Set Up 6 312964C Registering the TLM Graco recommend s registering TLM prior to installa- tion. The TLM operating pa rameters are cont rolled by the Matrix PC Software and setup by the System Adminis- trator . See the Matrix 3 Software instruction manual f or the PC setup instructions. T o regist er the TLM : 1. Set TLM to correct NETWORK ID and TR[...]

  • Page 7

    TLM Display 312964C 7 TLM Displa y (See F IG . 6, page 8) TLM ID - Unique number assign ed to the TLM to distin- guish it from oth er TLM’ s in the syst em. Batter y Life - Remaining lif e of the unit’ s batter ies. Sys- tem Administrator on Matr ix PC Software d eter mines when Low Batter y W ar n ing message is ge nerated. Netw ork ID and T r[...]

  • Page 8

    TLM Registration Process 8 312964C TLM Registration Pr ocess F IG . 5 Press & Hold DISPLA Y button Battery NW ID TX ID REGISTER MODE Ack received from T ransceiver No Ack received from T ransceiver TLM ID TLM ID TLM ID BLANK BLANK VERSION xx.xx.xx VERSION xx.xx.xx PC Responds with Registration Ack Message PC doesn’t Respond REGISTER COMPLETE [...]

  • Page 9

    Installation 312964C 9 Installation 1. Remo ve the b ung fitting and scre w in the TLM hand-tight. DO NOT use a wrench to tighte n as this ma y damage the TLM. Do not use thre ad lock adhe- siv e as this may d amage the TLM. 2. The TLM m ust be mounted with in 2 degrees from per pendicu lar to the surface of the fluid. A lev el that measures degr e[...]

  • Page 10

    Viewing Data 10 312964C Vie wing Data Press and release th e Display b utton (A). Data appears on displa y (B); each screen lasting a f ew seconds bef ore going on to the next. See F IG . 8. After a tank is refilled from an oil distributor or a waste oil tank is emptied b y a waste oil ser vice provide r , press the Display b utton on the TLM to en[...]

  • Page 11

    Troubleshooting 312964C 11 T r oubleshooting Prob lem Cause Solution Brand new monitor’ s dis- pla y is very dim. Unit is shipped with protective coat- ing o ver displa y . Remo ve protecti ve coating. Monitor displays “In valid Reading”. The TLM reading is outside of the programmed size parameters. V er ify the programmed parame te rs and re[...]

  • Page 12

    Troubleshooting 12 312964C Monitor readings are inaccurate. T a nk geometr y incorrectly defi ned. See T ank Lev el Monitor Software Guide or PC Software Guide fo r d e t a i l s . T a nk Lev el Monitor has not be en updated with latest adjustments made within The profile ID on the PC . Manually pu sh DISPLA Y button on TL M T wo TLMs are pr ogramm[...]

  • Page 13

    Service 312964C 13 Service Once the T ank Lev el Monitor has been in stalled, no additional maintenance or ser vice is necessar y , with the excep- tion of replac ing batteries. Replacing Batteries Alwa ys repl ace bot h batteries with two new 9- volt alkaline batte r ies whene ver y ou change batteries in the TLM. 1. Remove the four cov er screws [...]

  • Page 14

    Parts 14 312964C Pa r t s 3 2 1 1 Remov e protective cov er used for shipping before programming. Do not remov e. This is required to mainta in intrinsic safety approv al. 1 2 4 2 ti12033a 5 6 7 8 9 10 Ref. No. P ar t No. Description Qty 1 BA TTER Y , 9 volt (purch ased locally) 2 2 126752 GASKET , sensor , ultr asonic 1 3 117467 SCREW , self tappi[...]

  • Page 15

    Technical Data 312964C 15 Te c h n i c a l D a t a NO TE: FCC, C-Tic k and IC approvals are f or the RF device contained in the Matrix T ank Lev el Monitor (TLM). Ultrasonic T ank Depth Measurement rang e 0 - 30 ft. (0 - 9 m) Not f or use in pressurized t anks. Fluid Le vel Me asurement Accuracy +/- 0.5% Mounting Standard 2 in. (n pt) bung. Height [...]

  • Page 16

    Dimensions 16 312964C Dimensions A 9.1 in (231 mm) B 4.9 in. (124 mm) 1-1/2 in. npt A B 2 in. npt ti12031a[...]

  • Page 17

    Tank Geom etry 312964C 17 Ta n k G e o m e t r y V ertical T ank: • Maximum V olume = 999, 999 gallons or liters . • T ank walls must be uniformly ve r tical from empty lev el to full F IG . 10 ti12693a Maximum Height 30 ft. (360 in.)[...]

  • Page 18

    Tank Geomet ry 18 312964C Cylindrical T ank: • Maximum V olume = 999, 999 gallons or liters . • T ank end walls m ust be flat; th ey cannot be any other shape , including belled. F IG . 11 ti12695a Maximum Length Maximum Height 30 ft. (360 in) 30 ft. (360 in)[...]

  • Page 19

    Tank Geom etry 312964C 19 Obround T ank: • Maximum V olume = 999, 999 gallons or liters . • T ank end walls m ust be flat; the y cannot be any other shape inclu ding belled. F IG . 12 ti12694a Maximum Width 30 ft. (360 in .) Maximum Length Maximum Height 30 ft. (360 in) 30 ft. (360 in)[...]

  • Page 20

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. For patent information, see www.graco.com/patents. Original Instructions. This m anual co ntains English. MM 312964 Graco Headquarters: Minneapoli[...]