Graco 24B771 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 24B771, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 24B771 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 24B771. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 24B771 should contain:
- informations concerning technical data of Graco 24B771
- name of the manufacturer and a year of construction of the Graco 24B771 item
- rules of operation, control and maintenance of the Graco 24B771 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 24B771 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 24B771, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 24B771.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 24B771 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Kit Instr uctions/P ar ts DataT rak ® Kits 313840G EN For pro viding pump diagnost ics and material usage inf o rmation f or diaphragm pumps. Con ver sion Kits - DataT rak with Pulse Count and Runawa y Protection Husky ® 1050 - 24B777, 24B784, and 24B793 Husky ® 3300 - 24K861 and 24K862 Con ver sion Kits - Data T rak with Pulse Count Husky ® 10[...]

  • Page 2

    Contents 2 313840G Contents Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DataT rak Kit s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Prepare to In[...]

  • Page 3

    DataTrak Kits 313840G 3 DataT rak Kits Con versio n Kits Use to add data monitoring capabilities to an e xisting pump . * Kit includes repla cement air valv e compatib le with solenoid. Replacement P ar t Kits Aluminum P olypr opylene and Conductive P olyprop ylene Husky 1050 Husky 3300 Diaphragm Pump Material Data Monitoring Pulse Count and Runawa[...]

  • Page 4

    Installation 4 313840G Installation Prepare to Install 1. Relie ve the pressure. F ollow instructions in your Operat ion manual. 2. Disconnect the a ir line to the pump . Install the Kit 1. Mount t he brack et to the wall. Use approximately 3/8 in. bo lts or screws . 2. Install the DataT rak module (1) on the br acke t . 3. Con version Kits include[...]

  • Page 5

    Installation 313840G 5 6. Use the scre w provided to attach the r eed switch just behind the air inlet. Remov e the muffler , if needed, for easier access. Rotate the air inlet fitt ing as needed so th e wrench flat clears the reed s witch. 7. Connect the Da taT rak cab le to the 5-pin connector on the reed s witch. Reconnect the air line to the mo[...]

  • Page 6

    DataTrak Controls and Indicators 6 313840G DataT rak Contr ols and Indicator s Key AA Runaw ay Lim it, in cycles per minute (user settable; 00=OFF) AB Displacement (user settable) A C Flow Rate Units (user settable to gpm [US], gpm [Imperial], oz/min [US], oz /min [Imperial], l/min, or cc/min) AD LED (f aul t indicator when flashing) AE Displa y PF[...]

  • Page 7

    DataTrak Operation 313840G 7 DataT rak Operation NO TE: The display (AE) will turn off after 1 minute to sav e batter y lif e. Press any ke y to wake up the displa y . NO TE: DataT rak is f actor y se t to 685 cc/cy cle. This set- ting is accur ate f or pumping water at a medium speed on a Husky 1050 pump (a pproxima tely 20 gpm). The DataT rak ca [...]

  • Page 8

    DataTrak Operation 8 313840G NO TE: If the DataT rak does not r eset, use a scr ewdriver to push the sole noid release butt on on the side of the air va lve . 5. If the so lenoid doesn’t actuate: a. Close the master air v alve to stop the pump. The displa y will show the Ser vice Component 1 screen. b. S e e T able 1, Diag nostic Codes , on page [...]

  • Page 9

    DataTrak Operation 313840G 9 Calibration Pr ocedure 1. Press and hold f or 5 seconds until Setup me nu appears . 2. Press once. Change flo w rate units to cycles/min. 3. Retur n to Run Screen. Press a nd hold for three seconds to reset batch to talizer . 4. Dispense fluid fr om pump into a graduated con- tainer . 5. Con ver t the actual v olume dis[...]

  • Page 10

    DataTrak Operation 10 313840G T able 1: Diagnostic Codes Symbol Code Code Name Diagnosis Cause Runa wa y Pump running f aster than set runawa y limit. Increased air pressure. Increased flu id output. Exhausted fluid supply . E-3 Low Battery Batter y v oltage too low t o stop r unawa y . Low batt er y . Replace batte r y; see page 11. E--4 Ser vice [...]

  • Page 11

    DataTrak Operation 313840G 11 Replace DataT rak Battery or Fuse Replace Battery 1. Unscrew cable from the reed s witch asse mbly . See Fig. 2. 2. Remove DataT rak module from bracket. See Fig. 3. T ak e module to a non-hazardous locati on. 3. Remo ve two scre ws on bac k of module to access battery . 4. Disconnect th e used batter y and replace wit[...]

  • Page 12

    DataTrak Operation 12 313840G Replace Fuse 1. Remove the screw , metal s trap , and pl astic holder . 2. Pull the fuse awa y from the bo ard. 3. Replace with a new fuse. * Fig. 4 shows whe re to find the Series letter . T able 3. Appr oved Fuse s DataT rak Pa r t Number Series* Fuse Required 289822 A or B 24C580 C and later 24V216 All other par t n[...]

  • Page 13

    DataTrak Operation 313840G 13[...]

  • Page 14

    Parts 14 313840G Pa r t s Con version Kits, Cyc le Count and Runawa y Protection Husky 1050 - 24B777 (Aluminu m), 24B784 (P olypro pylene), and 24B793 ( Conductive P olypr opylene) Husky 3300 - 24K861 (Alumi num) and 24K862 (P olypr opylene) ti14052a Aluminum Plastic 1 2 3 4a 4b Aluminum Plastic 6a 6b 6c 6a 6b 6c 4d 4c ti14226a ti14225a 4d 4c[...]

  • Page 15

    Parts 313840G 15 ▲ Replacement W a rning labels, signs , tags, and cards are a vailab le at no cost. ----- Not sold separately . Ref. No. Part No. Descr iption Qty 1 ----- D A T A TRAK module (see pages 11 and 12 for bat ter y and fuse repl acement inf or mation) 1 2 ----- CABLE 1 3 ----- BRA CKET , wall 1 4 SOLENOID/REED SWITCH, kit (includes P [...]

  • Page 16

    Parts 16 313840G Con version Kits, Cyc le Count Only Husky 1050 and Husky 3300 - 24B794 (Aluminum) and 24 B795 (P olypr opylene and Conductive P olypropylene) ▲ Replacement W a rning labels, signs , tags, and car ds are av ailable at no cost. 1 2 3 5a 5b ti14224a Ref. No. P ar t No. Description Qty 1 ----- D A T A TRAK m odule (see pages 11 and 1[...]

  • Page 17

    Parts 313840G 17 Replacement Kits Solenoid/Reed Switch Reed Switch Husky 1050 Husky 3300 Air V alve Material Incl udes 24B771 24K863 Plastic Reed s witch and solenoid (4a), brac ket ( 4c), and fa steners (4b , 4d) 24B772 24K864 Aluminum Husky 1050 or Husky 3300 Air V alve Material Incl udes 24B796 Plastic Reed s witch (5a) and f astener (5b) 24B798[...]

  • Page 18

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions.This m anual contains English. MM 313840 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea[...]